Contact Us:
sales@inosaki.com

SIMATIC S7-300 CPU 317TF-3 PN/DP – Siemens PLC

$ 9,083.05

SKU 6ES7317-7UL10-0AB0 Category

The CPU 317TF-3 PN/DP is a controller that enables motion control, standard and safety tasks to be performed in one controller. It is used in machines where a controller with a large program memory and high processing speed is confronted by motion control requirements at the same time.

Siemens PLC S7-300 Product Specifications:

Article number 6ES7317-7UL10-0AB0
CPU317TF-3 PN/DP, 1,5 MB
General information
HW functional status 1
Firmware version CPU: V3.2; integrated technology V4.1.5
Product function
● Isochronous mode Yes; Via PROFIBUS DP or PROFINET interface
Engineering with
● Programming package STEP 7 V5.5 SP2 or higher; S7-Technology option package V4.2 SP3 or higher, Distributed Safety V5.4 SP5 or higher, S7-F Configuration Pack V5.5 SP10 or higher
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
external protection for power supply lines (recommendation) 2 A min.
Load voltage L+
● Rated value (DC) 24 V
● Reverse polarity protection Yes
Digital outputs
— Rated value (DC) 24 V; 2L+
— Reverse polarity protection No; 2L+
Input current
Current consumption (rated value) 1 100 mA
Current consumption (in no-load operation), typ. 270 mA
Inrush current, typ. 6.5 A
I²t 1 A²·s
Power loss
Power loss, typ. 8.5 W
Memory
Work memory
● integrated 1 536 kbyte
● expandable No
Load memory
● Plug-in (MMC) Yes
● Plug-in (MMC), max. 8 Mbyte
● Data management on MMC (after last programming), min. 10 y
Backup
● present Yes; Guaranteed by MMC (maintenance-free)
● without battery Yes; Program and data
CPU processing times
for bit operations, typ. 0.025 µs
for word operations, typ. 0.03 µs
for fixed point arithmetic, typ. 0.04 µs
for floating point arithmetic, typ. 0.16 µs
CPU-blocks
Number of blocks (total) 2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
● Number, max. 2 048; Number range: 1 to 16000
● Size, max. 64 kbyte
FB
● Number, max. 2 048; Number range: 0 to 7999
● Size, max. 64 kbyte
FC
● Number, max. 2 048; Number range: 0 to 7999
● Size, max. 64 kbyte
OB
● Number, max. see instruction list
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of delay alarm OBs 2; OB 20, 21
● Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35
● Number of process alarm OBs 1; OB 40
● Number of DPV1 alarm OBs 3; OB 55, 56, 57
● Number of isochronous mode OBs 1; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously)
● Number of technology synchronous alarm OBs 1; OB 65
● Number of startup OBs 1; OB 100
● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 16
● additional within an error OB 4
Counters, timers and their retentivity
S7 counter
● Number 512
Retentivity
— adjustable Yes
— lower limit 0
— upper limit 511
— preset Z 0 to Z 7
Counting range
— adjustable Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
S7 times
● Number 512
Retentivity
— adjustable Yes
— lower limit 0
— upper limit 511
— preset No retentivity
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 256 kbyte
Flag
● Size, max. 4 096 byte
● Retentivity available Yes; From MB 0 to MB 4 095
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8; 1 memory byte
Data blocks
● Retentivity adjustable Yes; via non-retain property on DB
● Retentivity preset Yes
Local data
● per priority class, max. 32 768 byte; Max. 2048 bytes per block
Address area
I/O address area
● Inputs 8 192 byte
● Outputs 8 192 byte
of which distributed
— Inputs 8 192 byte
— Outputs 8 192 byte
Process image
● Inputs 8 192 byte
● Outputs 8 192 byte
● Inputs, adjustable 8 192 byte
● Outputs, adjustable 8 192 byte
● Inputs, default 1 024 byte
● Outputs, default 1 024 byte
Default addresses of the integrated channels
— Digital inputs 66
— Digital outputs 66
Subprocess images
● Number of subprocess images, max. 1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
● Inputs 65 536
— of which central 256
● Outputs 65 536
— of which central 256
Analog channels
● Inputs 4 096
— of which central 64
● Outputs 4 096
— of which central 64
Hardware configuration
Number of expansion units, max. 0
Number of DP masters
● integrated 2; 1 DP and 1 DP (drive)
● via CP 2; for DP
Number of operable FMs and CPs (recommended)
● FM 8
● CP, PtP 8
● CP, LAN 8
Rack
● Racks, max. 1
● Modules per rack, max. 8
Time of day
Clock
● Hardware clock (real-time) Yes
● retentive and synchronizable Yes
● Backup time 6 wk; At 40 °C ambient temperature
● Deviation per day, max. 10 s; Typ.: 2 s
● Behavior of the clock following POWER-ON Clock continues running after POWER OFF
● Behavior of the clock following expiry of backup period the clock continues at the time of day it had when power was switched off
Operating hours counter
● Number 4
● Number/Number range 0 to 3
● Range of values 0 to 2^31 hours (when using SFC 101)
● Granularity 1 h
● retentive Yes; Must be restarted at each restart
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes
● to DP, slave Yes; Only time-of-day slave
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes; As client
Digital inputs
Number of digital inputs 4
● of which inputs usable for technological functions 4
Input characteristic curve in accordance with IEC 61131, type 1 Yes
Number of simultaneously controllable inputs
horizontal installation
— up to 40 °C, max. 4
— up to 60 °C, max. 4
vertical installation
— up to 40 °C, max. 4
Input voltage
● Rated value (DC) 24 V
● for signal “0” -3 to +5V
● for signal “1” +15 to +30 V
Input current
● for signal “1”, typ. 7 mA
Input delay (for rated value of input voltage)
for technological functions
— at “0” to “1”, max. 10 µs; Typical
— at “1” to “0”, max. 10 µs; Typical
Cable length
● shielded, max. 1 000 m
Digital outputs
Number of digital outputs 8
● of which high-speed outputs 8
Functions for technology functions, e.g. high-speed cam switch signals
Short-circuit protection Yes
● Response threshold, typ. 1 A
Limitation of inductive shutdown voltage to 48 V
Controlling a digital input No
Switching capacity of the outputs
● on lamp load, max. 5 W
Load resistance range
● lower limit 48 Ω
● upper limit 4 kΩ
Output voltage
● for signal “0”, max. 3 V; (2L+)
● for signal “1”, min. Rated voltage -2.5 V
Output current
● for signal “1” rated value 0.5 A
● for signal “1” permissible range for 0 to 60 °C, min. 5 mA
● for signal “1” permissible range for 0 to 60 °C, max. 0.6 A
● for signal “0” residual current, max. 0.3 mA
Parallel switching of two outputs
● for uprating No
● for redundant control of a load No
Switching frequency
● with resistive load, max. 100 Hz
● with inductive load, max. 0.2 Hz; According to IEC 60947-5-1, DC-13
● on lamp load, max. 100 Hz
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max. 4 A
— up to 60 °C, max. 3 A
all other mounting positions
— up to 40 °C, max. 4 A
Integrated high-speed cams
● Switching accuracy (+/-) 70 µs
Cable length
● shielded, max. 1 000 m
Analog inputs
Number of analog inputs 0
Analog outputs
Number of analog outputs 0
Encoder
Connectable encoders
● 2-wire sensor No
Interfaces
Number of industrial Ethernet interfaces 1
Number of PROFINET interfaces 1
Number of RS 485 interfaces 2
Number of RS 422 interfaces 0
1. Interface
Interface type Integrated RS 485 interface
Isolated Yes
Interface types
● RS 485 Yes
● Output current of the interface, max. 200 mA
Protocols
● MPI Yes
● PROFIBUS DP master Yes
● PROFIBUS DP slave Yes
● Point-to-point connection No
MPI
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No; but via CP and loadable FB
— S7 communication, as server Yes
PROFIBUS DP master
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 124
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes; I blocks only
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Equidistance Yes
— Isochronous mode Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Number of DP slaves that can be simultaneously activated/deactivated, max. 8
— Direct data exchange (slave-to-slave communication) Yes; as subscriber
— DPV1 Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
PROFIBUS DP slave
● Transmission rate, max. 12 Mbit/s
● automatic baud rate search Yes; only with passive interface
● Address area, max. 32
● User data per address area, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes; Only with active interface
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes; Connection configured on one side only
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2. Interface
Interface type Integrated RS 485 interface
Isolated Yes
Interface types
● RS 485 Yes
● Output current of the interface, max. 200 mA
Protocols
● MPI No
● PROFIBUS DP master Yes; DP(DRIVE)-Master
● PROFIBUS DP slave No
● Point-to-point connection No
PROFIBUS DP master
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 64
Services
— PG/OP communication No
— Routing No
— Global data communication No
— S7 basic communication No
— S7 communication No
— Equidistance Yes
— Isochronous mode Yes
— SYNC/FREEZE No
— Activation/deactivation of DP slaves Yes
— DPV1 No
Address area
— Inputs, max. 1 024 byte
— Outputs, max. 1 024 byte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
PROFIBUS DP slave
● GSD file http://support.automation.siemens.com in Product Support area
● Transmission rate, max. 12 Mbit/s
3. Interface
Interface type PROFINET
Isolated Yes
automatic detection of transmission rate Yes; 10/100 Mbit/s
Autonegotiation Yes
Autocrossing Yes
Change of IP address at runtime, supported Yes
Interface types
● RJ 45 (Ethernet) Yes
● Number of ports 2
● integrated switch Yes
Protocols
● MPI No
● PROFINET IO Controller Yes; Also simultaneously with IO-Device functionality
● PROFINET IO Device Yes; Also simultaneously with IO Controller functionality
● PROFIBUS DP master No
● PROFIBUS DP slave No
● Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP
● Web server Yes
● Media redundancy Yes
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— S7 communication Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
— Isochronous mode Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
— Shared device Yes
— Prioritized startup Yes
— Number of IO devices with prioritized startup, max. 32
— Number of connectable IO Devices, max. 128
— Of which IO devices with IRT, max. 64
— of which in line, max. 64
— Number of connectable IO Devices for RT, max. 128
— of which in line, max. 128
— Activation/deactivation of IO Devices Yes
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8
— IO Devices changing during operation (partner ports), supported Yes
— Number of IO Devices per tool, max. 8
— Device replacement without swap medium Yes
— Send cycles 250 µs, 500 µs, 1 ms, 2 ms, 4 ms
— Updating time 250 µs to 512 ms (depending on the operating mode, see Manual “S7-300 CPU 31xC and CPU 31x, technical Data” for more details)
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
— User data consistency, max. 1 024 byte
PROFINET IO Device
Services
— PG/OP communication Yes
— Routing Yes
— S7 communication Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
— Isochronous mode No
— IRT Yes
— PROFIenergy Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
— Shared device Yes
— Number of IO Controllers with shared device, max. 2
Transfer memory
— Inputs, max. 1 440 byte; Per IO Controller with shared device
— Outputs, max. 1 440 byte; Per IO Controller with shared device
Submodules
— Number, max. 64
— User data per submodule, max. 1 024 byte
Open IE communication
● Number of connections, max. 16
● Local port numbers used at the system end 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
● Keep-alive function, supported Yes
Protocols
PROFIsafe Yes
Redundancy mode
Media redundancy
— Switchover time on line break, typ. 200 ms; PROFINET MRP
— Number of stations in the ring, max. 50
Open IE communication
● TCP/IP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 16
— Data length for connection type 01H, max. 1 460 byte
— Data length for connection type 11H, max. 32 768 byte
— several passive connections per port, supported Yes
● ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 16
— Data length, max. 32 768 byte
● UDP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 16
— Data length, max. 1 472 byte
Web server
● supported Yes
● User-defined websites Yes
● Number of HTTP clients 5
communication functions / header
PG/OP communication Yes
Data record routing Yes
Global data communication
● supported Yes
● Number of GD loops, max. 8
● Number of GD packets, max. 8
● Number of GD packets, transmitter, max. 8
● Number of GD packets, receiver, max. 8
● Size of GD packets, max. 22 byte
● Size of GD packet (of which consistent), max. 22 byte
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● supported Yes
● as server Yes
● as client Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
● User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
● supported Yes; via CP and loadable FC
Number of connections
● overall 32
● usable for PG communication 31
— reserved for PG communication 1
— adjustable for PG communication, min. 1
— adjustable for PG communication, max. 31
● usable for OP communication 31
— reserved for OP communication 1
— adjustable for OP communication, min. 1
— adjustable for OP communication, max. 31
● usable for S7 basic communication 30
— reserved for S7 basic communication 0
— adjustable for S7 basic communication, min. 0
— adjustable for S7 basic communication, max. 30
● usable for S7 communication 16
— reserved for S7 communication 0
— adjustable for S7 communication, min. 0
— adjustable for S7 communication, max. 16
● total number of instances, max. 32
● usable for routing X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions
Number of login stations for message functions, max. 32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 300
Test commissioning functions
Status block Yes; Up to 2 simultaneously
Single step Yes
Number of breakpoints 4; without continuation
Status/control
● Status/control variable Yes
● Variables Inputs, outputs, memory bits, DB, times, counters
● Number of variables, max. 30
— of which status variables, max. 30
— of which control variables, max. 14
Forcing
● Forcing Yes
● Forcing, variables Inputs, outputs
● Number of variables, max. 10
Diagnostic buffer
● present Yes
● Number of entries, max. 500
— adjustable No
— of which powerfail-proof 100; Only the last 100 entries are retained
● Number of entries readable in RUN, max. 499
— adjustable Yes; From 10 to 499
— preset 10
Service data
● can be read out Yes
Interrupts/diagnostics/status information
Alarms No
Diagnostics function No
Diagnostics indication LED
● Status indicator digital input (green) Yes
● Status indicator digital output (green) Yes
Potential separation
Potential separation digital inputs
● between the channels and backplane bus Yes
Potential separation digital outputs
● between the channels and backplane bus Yes
Isolation
Isolation tested with 500 V DC
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 60 °C
configuration / header
Configuration software
● STEP 7 Yes; STEP 7 V5.5 SP2 or higher and S7-Technology Option Package V4.2 SP3, S7 F Configuration Pack V5.5 SP10, S7 Distributed Safety Option Package V5.4 SP5
configuration / programming / header
● Command set see instruction list
● Nesting levels 8
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Know-how protection
● User program protection/password protection Yes
● Block encryption Yes; With S7 block Privacy
Dimensions
Width 120 mm
Height 125 mm
Depth 130 mm
Weights
Weight, approx. 640 g

Additional information

Weight 0.729 kg
Dimensions 13.2 × 15.2 × 13.1 cm

Related Products

Banner_QS30FF400_1
SICK_sensor_Inductive proximity sensor_IM AC_IM18-08NUO-ZU0
PHOENIX CONTACT_POWER SUPPLY_TRIOPOWER__2903160
Festo_Guided cylinders_SLS-16-10-P-A_170498
Banner_QS18VN6AF100Q5_1
PANASONIC_Compact Inductive Proximity Sensor-GH-3SE
Select your currency