| Model |
EM DR16 |
EM DT16 |
EM DR32 |
EM DT32 |
| Order No.: (MLFB) |
6ES7 288-2DR16-0AA0 |
6ES7 288-2DT16-0AA0 |
6ES7 288-2DR32-0AA0 |
6ES7 288-2DT32-0AA0 |
| Dimension W x H x D (mm) |
45 x 100 x 81 |
70 x 100 x 81 |
| Weight |
201.9 g |
179.7 g |
295.4 g |
257.3 g |
| Power consumption |
5.5 W |
2.5 W |
10 W |
4.5 W |
| Current consumption (SM bus) |
145 mA |
145 mA |
180 mA |
185 mA |
| Current consumption (24 V DC) |
4 mA for each input point used |
| Each relay coil used is 11 mA |
|
| Each relay coil used is 11 mA |
|
|
| Digital input |
| Number of input points |
8 |
16 |
| Type |
The sinking / sourcing type (IEC type 1 sinking) |
| Rated voltage |
It is 24V DC when the current is 4 mA, nominal value |
| Allowable continuous voltage |
Max 30 V DC |
| Surge voltage |
35 V DC, lasting 0.5 s |
| Logic 1 signal (min) |
15 V DC |
| Logic 0 signal (min) |
5 V DC |
| Isolation (field side and logic side) |
500 V AC, lasting 1 min |
| Isolation group |
2 |
| Filter time |
0.2, 0.4, 0.8, 1.6, 3.2, 6.4 and 12.8 ms (optional, 4 form one group) |
| Number of inputs that connect at the same time |
8 |
|
| Cable length |
500 m (Shielded), 150 m (non shielded) |
| Digital output |
| Number of output |
8 |
16 |
| Type |
Relay, dry contact |
Solid state-MOSFET |
Relay, dry contact |
Solid state-MOSFET |
| Voltage range |
5 ~ 30 V DC or 5 ~ 250 V AC |
20.4 ~ 28.8 V DC |
5 ~ 30 V DC or 5 ~ 250 V AC |
20.4 ~ 28.8 V DC |
| Logic 1 signal when the current is max. |
– |
Min. 20 V DC |
– |
Min. 20 V DC |
| Logic 0 signal when the load is KG |
– |
Max. 0.1 V DC |
– |
Max. 0.1 V DC |
| Rated current at each point (max) |
2:00 AM |
0.75 A |
2:00 AM |
0.75 A |
| Lamp load |
30 W DC/200 W AC |
5 W |
30 W DC/200 W AC |
5 W |
| Resistance of the contact in the ON state |
New equipment is 0.2 Ω maximally |
Max. 0.6 Ω |
New equipment is 0.2 Ω maximally |
Max. 0.6 Ω |
| Leakage current at each point |
– |
Max. 10 μ A |
– |
Max. 10 μ A |
| Surge current |
It is 7A when the contact is closed |
8 A, max. lasting 100 ms |
It is 7A when the contact is closed |
8 A, max. lasting 100 ms |
| Overload protection |
none |
|
|
|
| Isolation (field side and logic side) |
1500 V AC, lasting 1 min (coil and contact) none, (coil and logic side) |
500 V AC, lasting 1 min |
1500 V AC, lasting 1 min (coil and contact) none, (coil and logic side) |
500 V AC, lasting 1 min |
| Isolation resistance |
New equipment is 100 MΩ minimally |
– |
New equipment is 100 MΩ minimally |
– |
| Disconnect the insulation between the contacts |
750 V AC, lasting 1 min |
– |
750 V AC, lasting 1 min |
– |
| Isolated group |
2 |
2 |
4 |
3 |
| Each end of the current public |
8:00 AM |
3:00 AM |
8:00 AM |
6:00 AM |
| Inductive voltage clamp |
– |
-48 V |
– |
-48 V |
| Switching delay |
Max.10 ms |
From the disconnection to connection max.50 μs from the connection to disconnection is 200 μs max. |
Max.10 ms. |
From the disconnection to connection max. 50 μs from the connection to disconnection is 200 μs max. |
| Mechanical life (no load) |
10,000,000 break/close cycles |
– |
10,000,000 break/close cycles |
– |
| Contact life under the rated load |
100,000 break/close cycles |
– |
100,000 break/close cycles |
– |
| Output state under the STOP mode |
Last value or replicable value (The default value is 0) |
| Number of output that are connected at the same time |
8 |
16 |
| Cable length |
Shielded: 500 m; non shielded: 300 m |