$ 135.52 – $ 204.82
Article number | 6ES7222-1BF32-0XB0 | 6ES7222-1BH32-0XB0 | 6ES7222-1BH32-1XB0 | 6ES7222-1HF32-0XB0 | 6ES7222-1HH32-0XB0 | 6ES7222-1XF32-0XB0 |
Digital Output SM1222, 8 DO, 24V DC | Digital Output SM1222, 16 DO, 24V DC | Digital Output SM1222, 16DO, 24V DC sink | Digital Output SM 1222, 8 DO, Relay | Digital Output SM1222, 16 DO, Relay | Digital Output SM 1222, 8 DO, Changeover | |
General information | ||||||
Product type designation | SM 1222, DQ 8×24 V DC/0.5 A | SM 1222, DQ 16×24 V DC/0.5 A | SM 1222, DO 16x 24 V DC/0.5 A Sink | SM 1222, DQ 8x relay/2 A | SM 1222, DQ 16x relay/2 A | SM 1222, DQ 8x relay/2 A |
Supply voltage | ||||||
permissible range, lower limit (DC) | 20.4 V | 20.4 V | 20.4 V | 20.4 V | 20.4 V | 20.4 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V |
Input current | ||||||
from backplane bus 5 V DC, max. | 120 mA | 140 mA | 140 mA | 120 mA | 135 mA | 140 mA |
Digital outputs | ||||||
● from load voltage L+, max. | 11 mA/relay coil | 11 mA/relay coil | 16.7 mA/relay coil | |||
Power loss | ||||||
Power loss, typ. | 1.5 W | 2.5 W | 2.5 W | 4.5 W | 8.5 W | 5 W |
Digital outputs | ||||||
Number of digital outputs | 8 | 16 | 16 | 8 | 16 | 8 |
● in groups of | 1 | 1 | 1 | 2 | 1 | 1 |
Current-sinking | Yes | |||||
Short-circuit protection | No; to be provided externally | No; to be provided externally | No; to be provided externally | No; to be provided externally | No; to be provided externally | No; to be provided externally |
Limitation of inductive shutdown voltage to | typ. (L+) -48 V | typ. (L+) -48 V | Typ 45 V | |||
Switching capacity of the outputs | ||||||
● with resistive load, max. | 0.5 A | 0.5 A | 0.5 A | 2 A | 2 A | 2 A |
● on lamp load, max. | 5 W | 5 W | 5 W | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC |
Output voltage | ||||||
● Rated value (DC) | 24 V | 24 V | 24 V | 5 V DC to 30 V DC | 5 V DC to 30 V DC | 5 V DC to 30 V DC |
● Rated value (AC) | 5 V AC to 250 V AC | 5 V AC to 250 V AC | 5 V AC to 250 V AC | |||
● for signal “0”, max. | 0.1 V; with 10 kOhm load | 0.1 V; with 10 kOhm load | L+ minus 0.75 V DC with 10k Load | |||
● for signal “1”, min. | 20 V DC | 20 V DC | 0,5 V | |||
Output current | ||||||
● for signal “1” rated value | 0.5 A | 0.5 A | 0.5 A | 2 A | 2 A | 2 A |
● for signal “0” residual current, max. | 10 µA | 10 µA | 75 µA | |||
Output delay with resistive load | ||||||
● “0” to “1”, max. | 50 µs | 50 µs | 20 µs | 10 ms | 10 ms | 10 ms |
● “1” to “0”, max. | 200 µs | 200 µs | 350 µs | 10 ms | 10 ms | 10 ms |
Total current of the outputs (per group) | ||||||
horizontal installation | ||||||
— up to 50 °C, max. | 4 A; Current per mass | 8 A; Current per mass | 8 A; Current per mass | 10 A; Current per mass | 10 A; Current per mass | 2 A; Current per mass |
Relay outputs | ||||||
● Number of relay outputs | 8 | 16 | 8 | |||
● Rated supply voltage of relay coil L+ (DC) | 24 V | 24 V | 24 V | |||
● Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100 000 | mechanically 10 million, at rated load voltage 100 000 | mechanically 10 million, at rated load voltage 100 000 | |||
Switching capacity of contacts | ||||||
— with inductive load, max. | 0.5 A | 0.5 A | 0.5 A | 2 A | 2 A | 2 A |
— on lamp load, max. | 5 W | 5 W | 5 W | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC |
— with resistive load, max. | 0.5 A | 0.5 A | 0.5 A | 2 A | 2 A | 2 A |
Cable length | ||||||
● shielded, max. | 500 m | 500 m | 500 m | 500 m | 500 m | 500 m |
● unshielded, max. | 150 m | 150 m | 150 m | 150 m | 150 m | 150 m |
Interrupts/diagnostics/status information | ||||||
Alarms | ||||||
● Diagnostic alarm | Yes | Yes | Yes | Yes | Yes | Yes |
Diagnostics indication LED | ||||||
● for status of the outputs | Yes | Yes | Yes | Yes | Yes | Yes |
Potential separation | ||||||
Potential separation digital outputs | ||||||
● between the channels | Relays | Relays | Relays | |||
● between the channels, in groups of | 1 | 1 | 1 | 2 | 4 | 1 |
● between the channels and backplane bus | 500 V AC | 500 V AC | 500 V AC | 1 500 V AC for 1 minute | 1 500 V AC for 1 minute | 1 500 V AC for 1 minute |
Permissible potential difference | ||||||
between different circuits | 750 V AC for 1 minute | 750 V AC for 1 minute | 750 V AC for 1 minute | |||
Degree and class of protection | ||||||
IP degree of protection | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 |
Standards, approvals, certificates | ||||||
CE mark | Yes | Yes | Yes | Yes | Yes | Yes |
CSA approval | Yes | Yes | Yes | Yes | Yes | Yes |
UL approval | Yes | Yes | Yes | Yes | Yes | Yes |
cULus | Yes | Yes | Yes | Yes | Yes | Yes |
FM approval | Yes | Yes | Yes | Yes | Yes | Yes |
RCM (formerly C-TICK) | Yes | Yes | Yes | Yes | Yes | Yes |
KC approval | Yes | Yes | Yes | Yes | Yes | Yes |
Marine approval | Yes | Yes | Yes | Yes | Yes | Yes |
Ambient conditions | ||||||
Free fall | ||||||
● Fall height, max. | 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package | |
Ambient temperature during operation | ||||||
● min. | -20 °C | -20 °C | -20 °C | -20 °C | -20 °C | -20 °C |
● max. | 60 °C | 60 °C | 60 °C | 60 °C | 60 °C; Number of simultaneously activated outputs: 8 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 16 at 55 °C horizontal or 45 °C vertical | 60 °C; Number of simultaneously activated outputs: 4 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 at 55 °C horizontal or 45 °C vertical |
● horizontal installation, min. | -20 °C | -20 °C | -20 °C | -20 °C | -20 °C | -20 °C |
● horizontal installation, max. | 60 °C | 60 °C | 60 °C | 60 °C | 60 °C | 60 °C |
● vertical installation, min. | -20 °C | -20 °C | -20 °C | -20 °C | -20 °C | -20 °C |
● vertical installation, max. | 50 °C | 50 °C | 50 °C | 50 °C | 50 °C | 50 °C |
● permissible temperature change | 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute |
Ambient temperature during storage/transportation | ||||||
● min. | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C |
● max. | 70 °C | 70 °C | 70 °C | 70 °C | 70 °C | 70 °C |
Air pressure acc. to IEC 60068-2-13 | ||||||
● Storage/transport, min. | 660 hPa | 660 hPa | 660 hPa | 660 hPa | 660 hPa | 660 hPa |
● Storage/transport, max. | 1 080 hPa | 1 080 hPa | 1 080 hPa | 1 080 hPa | 1 080 hPa | 1 080 hPa |
Relative humidity | ||||||
● Operation at 25 ℃ without condensation, max. | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % |
connection method / header | ||||||
required front connector | Yes | Yes | Yes | Yes | Yes | Yes |
Mechanics/material | ||||||
Enclosure material (front) | ||||||
● Plastic | Yes | Yes | Yes | Yes | Yes | Yes |
Dimensions | ||||||
Width | 45 mm | 45 mm | 45 mm | 45 mm | 45 mm | 70 mm |
Height | 100 mm | 100 mm | 100 mm | 100 mm | 100 mm | 100 mm |
Depth | 75 mm | 75 mm | 75 mm | 75 mm | 75 mm | 75 mm |
Weights | ||||||
Weight, approx. | 180 g | 220 g | 220 g | 190 g | 260 g | 310 g |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)