Contact Us:
sales@inosaki.com

SIMATIC S7-1200 – CPU 1211C – Siemens PLC

$ 257.14$ 272.55

Siemens PLC model SIMATIC S7-1200 controller is at the core of our offering for simple but highly precise automation tasks. The SIMATIC S7-1200 controller is modular and compact, versatile, a secure investment, and is perfectly suited to a whole range of applications.

Siemens PLC S7-1200 CPUs with Safety Integrated handle both standard and safety-related tasks. A compact design with integrated IO, communication interfaces that meet the highest industry requirements and a range of powerful integrated technological functions make this controller an integral part of a comprehensive automation solution. Siemens plc software are available for win cc find out more.

Siemens PLC S7-1200 Product Specifications:

Article number 6ES7211-1HE40-0XB0 6ES7211-1BE40-0XB0 6ES7211-1AE40-0XB0
CPU 1211C, DC/DC/Relay, 6DI/4DO/2AI CPU 1211C, AC/DC/Relay, 6DI/4DO/2AI CPU 1211C, DC/DC/DC, 6DI/4DO/2AI
General information
Product type designation CPU 1211C DC/DC/relay CPU 1211C AC/DC/relay CPU 1211C DC/DC/DC
Firmware version V4.5 V4.5 V4.5
Engineering with
● Programming package STEP 7 V17 or higher STEP 7 V17 or higher STEP 7 V17 or higher
Supply voltage
Rated value (DC)
● 24 V DC Yes Yes
permissible range, lower limit (DC) 20.4 V 20.4 V
permissible range, upper limit (DC) 28.8 V 28.8 V
Rated value (AC)
● 120 V AC Yes
● 230 V AC Yes
permissible range, lower limit (AC) 85 V
permissible range, upper limit (AC) 264 V
Reverse polarity protection Yes Yes
Line frequency
● permissible range, lower limit 47 Hz
● permissible range, upper limit 63 Hz
Load voltage L+
● Rated value (DC) 24 V 24 V
● permissible range, lower limit (DC) 20.4 V 20.4 V
● permissible range, upper limit (DC) 28.8 V 28.8 V
Input current
Current consumption (rated value) 300 mA; CPU only 60 mA at 120 V AC; 30 mA at 240 V AC 300 mA; CPU only
Current consumption, max. 900 mA; CPU with all expansion modules 180 mA at 120 V AC; 90 mA at 240 V AC 900 mA; CPU with all expansion modules
Inrush current, max. 12 A; at 28.8 V DC 20 A; at 264 V 12 A; at 28.8 V DC
I²t 0.8 A²·s 0.8 A²·s 0.5 A²·s
Output current
for backplane bus (5 V DC), max. 750 mA; Max. 5 V DC for CM 750 mA; Max. 5 V DC for CM 750 mA; Max. 5 V DC for CM
Encoder supply
24 V encoder supply
● 24 V L+ minus 4 V DC min. 20.4 to 28.8V L+ minus 4 V DC min.
Power loss
Power loss, typ. 8 W 10 W 8 W
Memory
Work memory
● integrated 50 kbyte 50 kbyte 50 kbyte
● expandable No No No
Load memory
● integrated 1 Mbyte 1 Mbyte 1 Mbyte
● Plug-in (SIMATIC Memory Card), max. with SIMATIC memory card with SIMATIC memory card with SIMATIC memory card
Backup
● present Yes Yes Yes
● maintenance-free Yes Yes Yes
● without battery Yes Yes Yes
CPU processing times
for bit operations, typ. 0.08 µs; / instruction 0.08 µs; / instruction 0.08 µs; / instruction
for word operations, typ. 1.7 µs; / instruction 1.7 µs; / instruction 1.7 µs; / instruction
for floating point arithmetic, typ. 2.3 µs; / instruction 2.3 µs; / instruction 2.3 µs; / instruction
CPU-blocks
Number of blocks (total) DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
OB
● Number, max. Limited only by RAM for code Limited only by RAM for code Limited only by RAM for code
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 14 kbyte 14 kbyte 14 kbyte
Flag
● Size, max. 4 kbyte; Size of bit memory address area 4 kbyte; Size of bit memory address area 4 kbyte; Size of bit memory address area
Local data
● per priority class, max. 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB
Address area
Process image
● Inputs, adjustable 1 kbyte 1 kbyte 1 kbyte
● Outputs, adjustable 1 kbyte 1 kbyte 1 kbyte
Hardware configuration
Number of modules per system, max. 3 communication modules, 1 signal board 3 communication modules, 1 signal board 3 communication modules, 1 signal board
Time of day
Clock
● Hardware clock (real-time) Yes Yes Yes
● Backup time 480 h; Typical 480 h; Typical 480 h; Typical
● Deviation per day, max. ±60 s/month at 25 °C ±60 s/month at 25 °C ±60 s/month at 25 °C
Digital inputs
Number of digital inputs 6; Integrated 6; Integrated 6; Integrated
● of which inputs usable for technological functions 6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
Source/sink input Yes Yes Yes
Number of simultaneously controllable inputs
all mounting positions
— up to 40 °C, max. 6 6 6
Input voltage
● Rated value (DC) 24 V 24 V 24 V
● for signal “0” 5 V DC at 1 mA 5 V DC at 1 mA 5 V DC at 1 mA
● for signal “1” 15 V DC at 2.5 mA 15 V DC at 2.5 mA 15 V DC at 2.5 mA
Input current
● for signal “1”, typ. 4 mA; nominal 4 mA; nominal 4 mA; nominal
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms
— at “0” to “1”, min. 0.2 ms 0.2 ms 0.2 ms
— at “0” to “1”, max. 12.8 ms 12.8 ms 12.8 ms
for interrupt inputs
— parameterizable Yes Yes Yes
for technological functions
— parameterizable Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz
Cable length
● shielded, max. 500 m; 50 m for technological functions 500 m; 50 m for technological functions 500 m; 50 m for technological functions
● unshielded, max. 300 m; for technological functions: No 300 m; for technological functions: No 300 m; for technological functions: No
Digital outputs
Number of digital outputs 4; Relays 4; Relays 4
● of which high-speed outputs 4; 100 kHz Pulse Train Output
Limitation of inductive shutdown voltage to L+ (-48 V)
Switching capacity of the outputs
● with resistive load, max. 2 A 2 A 0.5 A
● on lamp load, max. 30 W with DC, 200 W with AC 30 W with DC, 200 W with AC 5 W
Output voltage
● for signal “0”, max. 0.1 V; with 10 kOhm load
● for signal “1”, min. 20 V
Output current
● for signal “1” rated value 0.5 A
● for signal “0” residual current, max. 0.1 mA
Output delay with resistive load
● “0” to “1”, max. 10 ms; max. 10 ms; max. 1 µs
● “1” to “0”, max. 10 ms; max. 10 ms; max. 5 µs
Switching frequency
● of the pulse outputs, with resistive load, max. 100 kHz
Relay outputs
● Number of relay outputs 4 4 0
● Number of operating cycles, max. mechanically 10 million, at rated load voltage 100 000 mechanically 10 million, at rated load voltage 100 000
Cable length
● shielded, max. 500 m 500 m 500 m
● unshielded, max. 150 m 150 m 150 m
Analog inputs
Number of analog inputs 2 2 2
Input ranges
● Voltage Yes Yes Yes
Input ranges (rated values), voltages
● 0 to +10 V Yes Yes Yes
— Input resistance (0 to 10 V) ≥100k ohms ≥100k ohms ≥100k ohms
Cable length
● shielded, max. 100 m; twisted and shielded 100 m; twisted and shielded 100 m; twisted and shielded
Analog outputs
Number of analog outputs 0 0 0
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 10 bit 10 bit 10 bit
● Integration time, parameterizable Yes Yes Yes
● Conversion time (per channel) 625 µs 625 µs 625 µs
Encoder
Connectable encoders
● 2-wire sensor Yes Yes Yes
1. Interface
Interface type PROFINET PROFINET PROFINET
Isolated Yes Yes Yes
automatic detection of transmission rate Yes Yes Yes
Autonegotiation Yes Yes Yes
Autocrossing Yes Yes Yes
Interface types
● RJ 45 (Ethernet) Yes Yes Yes
● Number of ports 1 1 1
● integrated switch No No No
Protocols
● PROFINET IO Controller Yes Yes Yes
● PROFINET IO Device Yes Yes Yes
● SIMATIC communication Yes Yes Yes
● Open IE communication Yes; Optionally also encrypted Yes; Optionally also encrypted Yes; Optionally also encrypted
● Web server Yes Yes Yes
● Media redundancy No No No
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s 100 Mbit/s 100 Mbit/s
Services
— PG/OP communication Yes; encryption with TLS V1.3 pre-selected Yes; encryption with TLS V1.3 pre-selected Yes; encryption with TLS V1.3 pre-selected
— Isochronous mode No No No
— IRT No No No
— PROFIenergy No No No
— Prioritized startup Yes Yes Yes
— Number of IO devices with prioritized startup, max. 16 16 16
— Number of connectable IO Devices, max. 16 16 16
— Number of connectable IO Devices for RT, max. 16 16 16
— of which in line, max. 16 16 16
— Activation/deactivation of IO Devices Yes Yes Yes
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8 8 8
— Updating time The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
PROFINET IO Device
Services
— PG/OP communication Yes; encryption with TLS V1.3 pre-selected Yes; encryption with TLS V1.3 pre-selected Yes; encryption with TLS V1.3 pre-selected
— Isochronous mode No No No
— IRT No No No
— PROFIenergy Yes Yes Yes
— Shared device Yes Yes Yes
— Number of IO Controllers with shared device, max. 2 2 2
Protocols
Supports protocol for PROFINET IO Yes Yes Yes
PROFIsafe No No No
PROFIBUS Yes; CM 1243-5 (master) or CM 1242-5 (slave) required Yes; CM 1243-5 (master) or CM 1242-5 (slave) required Yes; CM 1243-5 (master) or CM 1242-5 (slave) required
OPC UA Yes; OPC UA Server Yes; OPC UA Server Yes; OPC UA Server
AS-Interface Yes; CM 1243-2 required Yes; CM 1243-2 required Yes; CM 1243-2 required
Protocols (Ethernet)
● TCP/IP Yes Yes Yes
● DHCP No No No
● SNMP Yes Yes Yes
● DCP Yes Yes Yes
● LLDP Yes Yes Yes
Redundancy mode
Media redundancy
— MRP No No No
— MRPD No No No
SIMATIC communication
● S7 routing Yes Yes Yes
Open IE communication
● TCP/IP Yes Yes Yes
— Data length, max. 8 kbyte 8 kbyte 8 kbyte
— several passive connections per port, supported Yes Yes Yes
● ISO-on-TCP (RFC1006) Yes Yes Yes
— Data length, max. 8 kbyte 8 kbyte 8 kbyte
● UDP Yes Yes Yes
— Data length, max. 1 472 byte 1 472 byte 1 472 byte
Web server
● supported Yes Yes Yes
● User-defined websites Yes Yes Yes
OPC UA
● Runtime license required Yes; “Basic” license required Yes; “Basic” license required Yes; “Basic” license required
● OPC UA Server Yes; data access (read, write, subscribe), method call, runtime license required Yes; data access (read, write, subscribe), method call, runtime license required Yes; Data access (read, write, subscribe), runtime license required
— Application authentication Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication “anonymous” or by user name & password “anonymous” or by user name & password “anonymous” or by user name & password
— Number of sessions, max. 10 10 10
— Number of subscriptions per session, max. 50 50 5
— Sampling interval, min. 100 ms 100 ms 100 ms
— Publishing interval, min. 200 ms 200 ms 200 ms
— Number of server methods, max. 20 20 20
— Number of monitored items, max. 1 000 1 000 1 000
— Number of server interfaces, max. 2 2 2
— Number of nodes for user-defined server interfaces, max. 2 000 2 000 2 000
Further protocols
● MODBUS Yes Yes Yes
communication functions / header
S7 communication
● supported Yes Yes Yes
● as server Yes Yes Yes
● as client Yes Yes Yes
● User data per job, max. See online help (S7 communication, user data size) See online help (S7 communication, user data size) See online help (S7 communication, user data size)
Number of connections
● overall PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max
Test commissioning functions
Status/control
● Status/control variable Yes Yes Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Forcing
● Forcing Yes Yes Yes
Diagnostic buffer
● present Yes Yes Yes
Traces
● Number of configurable Traces 2 2 2
● Memory size per trace, max. 512 kbyte 512 kbyte 512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LED Yes Yes Yes
● ERROR LED Yes Yes Yes
● MAINT LED Yes Yes Yes
Integrated Functions
Counter
● Number of counters 6 6 6
● Counting frequency, max. 100 kHz 100 kHz 100 kHz
Frequency measurement Yes Yes Yes
controlled positioning Yes Yes Yes
Number of position-controlled positioning axes, max. 8 8 8
Number of positioning axes via pulse-direction interface Up to 4 with SB 1222 Up to 4 with SB 1222 4; With integrated outputs
PID controller Yes Yes Yes
Number of alarm inputs 4 4 4
Number of pulse outputs 4
Limit frequency (pulse) 100 kHz
Potential separation
Potential separation digital inputs
● Potential separation digital inputs 500V AC for 1 minute 500V AC for 1 minute No
● between the channels, in groups of 1 1 1
Potential separation digital outputs
● Potential separation digital outputs Relays Relays Yes
● between the channels No No No
● between the channels, in groups of 1 1 1
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes Yes Yes
— Test voltage at air discharge 8 kV 8 kV 8 kV
— Test voltage at contact discharge 6 kV 6 kV 6 kV
Interference immunity to cable-borne interference
● Interference immunity on supply lines acc. to IEC 61000-4-4 Yes Yes Yes
● Interference immunity on signal cables acc. to IEC 61000-4-4 Yes Yes Yes
Interference immunity against voltage surge
● Interference immunity on supply lines acc. to IEC 61000-4-5 Yes Yes Yes
Interference immunity against conducted variable disturbance induced by high-frequency fields
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 Yes Yes Yes
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes; Group 1 Yes; Group 1 Yes; Group 1
● Limit class B, for use in residential areas Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
Degree and class of protection
IP degree of protection IP20 IP20 IP20
Standards, approvals, certificates
CE mark Yes Yes Yes
UL approval Yes Yes Yes
cULus Yes Yes Yes
FM approval Yes Yes Yes
RCM (formerly C-TICK) Yes Yes Yes
KC approval Yes Yes Yes
Marine approval Yes Yes Yes
Ambient conditions
Free fall
● Fall height, max. 0.3 m; five times, in product package 0.3 m; five times, in product package 0.3 m; five times, in product package
Ambient temperature during operation
● min. -20 °C -20 °C -20 °C
● max. 60 °C 60 °C 60 °C
● horizontal installation, min. -20 °C -20 °C -20 °C
● horizontal installation, max. 60 °C 60 °C 60 °C
● vertical installation, min. -20 °C -20 °C -20 °C
● vertical installation, max. 50 °C 50 °C 50 °C
Ambient temperature during storage/transportation
● min. -40 °C -40 °C -40 °C
● max. 70 °C 70 °C 70 °C
Air pressure acc. to IEC 60068-2-13
● Operation, min. 795 hPa 795 hPa 795 hPa
● Operation, max. 1 080 hPa 1 080 hPa 1 080 hPa
● Storage/transport, min. 660 hPa 660 hPa 660 hPa
● Storage/transport, max. 1 080 hPa 1 080 hPa 1 080 hPa
Altitude during operation relating to sea level
● Installation altitude, min. -1 000 m -1 000 m -1 000 m
● Installation altitude, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Relative humidity
● Operation, max. 95 %; no condensation 95 %; no condensation 95 %; no condensation
Vibrations
● Vibration resistance during operation acc. to IEC 60068-2-6 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
● Operation, tested according to IEC 60068-2-6 Yes Yes Yes
Shock testing
● tested according to IEC 60068-2-27 Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
Pollutant concentrations
● SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
configuration / header
configuration / programming / header
Programming language
— LAD Yes Yes Yes
— FBD Yes Yes Yes
— SCL Yes Yes Yes
Know-how protection
● User program protection/password protection Yes Yes Yes
● Copy protection Yes Yes Yes
● Block protection Yes Yes Yes
Access protection
● protection of confidential configuration data Yes Yes Yes
● Protection level: Write protection Yes Yes Yes
● Protection level: Read/write protection Yes Yes Yes
● Protection level: Complete protection Yes Yes Yes
programming / cycle time monitoring / header
● adjustable Yes Yes Yes
Dimensions
Width 90 mm 90 mm 90 mm
Height 100 mm 100 mm 100 mm
Depth 75 mm 75 mm 75 mm
Weights
Weight, approx. 380 g 420 g 370 g

Additional information

Weight N/A
Dimensions N/A

Related Products

BYD100-DDT
Festo_Compressed Air Regulator_LR-1-4-DB-7-O-MINI_537643
PEPPERL+FUCHS_Connectivity_V1-G-10M-PVC
Festo_Piston rod cylinders_DSNU-20-60-PPV-A-MH_193990 02
MOXA_WLAN AP-Bridge-Client_AWK-1131A-EU
BYD100-DDT
Select your currency