SIMATIC HMI – TP700 Comfort INOX – Siemens Comfort Panels
$ 3,423.74
SKU: 6AV2144-8GC10-0AA0
SIMATIC HMI TP700 Comfort INOX, Stainless steel front, Con- tinuous decorative film, Degree of protection front IP66K, 7″ widescreen TFT display, PROFINET interface, MPI/PROFIBUS DP interface, 12 MB configuration memory, Windows CE 6.0, (Microsoft Support included Security updates discontinued) configurable from WinCC Comfort V11
Siemens HMI Comfort Panels Product Specifications:
|
6AV2144-8GC10-0AA0 | |
SIMATIC HMI TP700 COMFORT INOX | ||
General information | ||
Product type designation | TP700 Comfort INOX | |
Display | ||
Design of display | TFT | |
Screen diagonal | 7 in | |
Display width | 152.4 mm | |
Display height | 91.4 mm | |
Number of colors | 16 777 216 | |
Resolution (pixels) | ||
● Horizontal image resolution | 800 pixel | |
● Vertical image resolution | 480 pixel | |
Backlighting | ||
● MTBF backlighting (at 25 °C) | 80 000 h | |
● Backlight dimmable | Yes; 0-100 % | |
Control elements | ||
Keyboard fonts | ||
● Function keys | ||
— Number of function keys | 0 | |
— Number of function keys with LEDs | 0 | |
● Keys with LED | No | |
● System keys | No | |
● Numeric keyboard | Yes; Onscreen keyboard | |
● alphanumeric keyboard | Yes; Onscreen keyboard | |
Touch operation | ||
● Design as touch screen | Yes | |
Expansions for operator control of the process | ||
● DP direct LEDs (LEDs as S7 output I/O) | ||
— F1…Fx | 0 | |
● Direct keys (keys as S7 input I/O) | ||
— F1…Fx | 0 | |
● Direct keys (touch buttons as S7 input I/O) | 32 | |
Installation type/mounting | ||
Mounting position | vertical | |
Mounting in portrait format possible | Yes | |
Mounting in landscape format possible | Yes | |
maximum permissible angle of inclination without external ventilation | 35° | |
Supply voltage | ||
Type of supply voltage | DC | |
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Input current | ||
Current consumption (rated value) | 0.5 A | |
Starting current inrush I²t | 0.5 A²·s | |
Power | ||
Active power input, typ. | 12 W | |
Processor | ||
Processor type | X86 | |
Memory | ||
Flash | Yes | |
RAM | Yes | |
Memory available for user data | 12 Mbyte | |
Type of output | ||
Info LED | No | |
Power LED | No | |
Error LED | No | |
Acoustics | ||
● Buzzer | No | |
● Speaker | Yes | |
Time of day | ||
Clock | ||
● Hardware clock (real-time) | Yes | |
● Software clock | Yes | |
● retentive | Yes; Back-up duration typically 6 weeks | |
● synchronizable | Yes | |
Interfaces | ||
Number of industrial Ethernet interfaces | 1; 2 ports (switch) | |
Number of RS 485 interfaces | 1; RS 422 / 485 combined | |
Number of RS 422 interfaces | 0; together with RS 485 | |
Number of RS 232 interfaces | 0 | |
Number of USB interfaces | 2; USB 2.0 | |
● USB Mini B | 1; 5-pole | |
Number of 20 mA interfaces (TTY) | 0 | |
Number of parallel interfaces | 0 | |
Number of other interfaces | 0 | |
Number of SD card slots | 2 | |
With software interfaces | No | |
Industrial Ethernet | ||
● Industrial Ethernet status LED | 2 | |
● Number of ports of the integrated switch | 2 | |
Protocols | ||
PROFINET | Yes | |
Supports protocol for PROFINET IO | Yes | |
IRT | Yes; As of WinCC V12 | |
PROFIBUS | Yes | |
EtherNet/IP | Yes | |
MPI | Yes | |
Protocols (Ethernet) | ||
● TCP/IP | Yes | |
● DHCP | Yes | |
● SNMP | Yes | |
● DCP | Yes | |
● LLDP | Yes | |
WEB characteristics | ||
● HTTP | Yes | |
● HTTPS | Yes | |
● HTML | Yes | |
● XML | Yes | |
● CSS | Yes | |
● Active X | Yes | |
● JavaScript | Yes | |
● Java VM | No | |
Redundancy mode | ||
Media redundancy | ||
— MRP | Yes; As of WinCC V12 | |
Further protocols | ||
● CAN | No | |
● MODBUS | Yes | |
Interrupts/diagnostics/status information | ||
Diagnoses | ||
● Diagnostic information readable | ||
EMC | ||
Emission of radio interference acc. to EN 55 011 | ||
● Limit class A, for use in industrial areas | Yes | |
● Limit class B, for use in residential areas | No | |
Degree and class of protection | ||
IP (at the front) | IP66K | |
IP (rear) | IP20 | |
NEMA (front) | ||
● Enclosure Type 4 at the front | No | |
● Enclosure Type 4x at the front | Yes; indoor use only | |
Standards, approvals, certificates | ||
CE mark | Yes | |
cULus | Yes | |
FM approval | Yes | |
RCM (formerly C-TICK) | Yes | |
KC approval | Yes | |
EAC (formerly Gost-R) | Yes | |
Use in hazardous areas | ||
● ATEX Zone 2 | Yes | |
● ATEX Zone 22 | Yes | |
● IECEx Zone 2 | Yes | |
● IECEx Zone 22 | Yes | |
● cULus Class I Zone 1 | No | |
● cULus Class I Zone 2, Division 2 | Yes | |
● FM Class I Division 2 | Yes | |
Marine approval | ||
● Germanischer Lloyd (GL) | No | |
● American Bureau of Shipping (ABS) | No | |
● Bureau Veritas (BV) | No | |
● Det Norske Veritas (DNV) | No | |
● Korean Register of Shipping (KRS) | ||
● Lloyds Register of Shipping (LRS) | No | |
● Nippon Kaiji Kyokai (Class NK) | No | |
● Polski Rejestr Statkow (PRS) | No | |
● Chinese Classification Society (CCS) | ||
Ambient conditions | ||
Suited for indoor use | ||
Suited for outdoor use | ||
Ambient temperature during operation | ||
Operation (vertical installation) | ||
— For vertical installation, min. | 0 °C | |
— For vertical installation, max. | 50 °C | |
Operation (max. tilt angle) | ||
— At maximum tilt angle, min. | 0 °C | |
— At maximum tilt angle, max. | 40 °C | |
Operation (vertical installation, portrait format) | ||
— For vertical installation, min. | 0 °C | |
— For vertical installation, max. | 40 °C | |
Operation (max. tilt angle, portrait format) | ||
— At maximum tilt angle, min. | 0 °C | |
— At maximum tilt angle, max. | 35 °C | |
Ambient temperature during storage/transportation | ||
● min. | -20 °C | |
● max. | 60 °C | |
Relative humidity | ||
● Operation, max. | 90 %; no condensation | |
Operating systems | ||
proprietary | No | |
pre-installed operating system | ||
● Windows CE | Yes | |
configuration / header | ||
Message indicator | Yes | |
Alarm system (incl. buffer and acknowledgment) | Yes | |
Process value display (output) | Yes | |
Process value default (input) possible | Yes | |
Recipe management | Yes | |
Configuration software | ||
● STEP 7 Basic (TIA Portal) | No | |
● STEP 7 Professional (TIA Portal) | No | |
● WinCC flexible Compact | No | |
● WinCC flexible Standard | No | |
● WinCC flexible Advanced | No | |
● WinCC Basic (TIA Portal) | No | |
● WinCC Comfort (TIA Portal) | Yes; from V11 | |
● WinCC Advanced (TIA Portal) | Yes; from V11 | |
● WinCC Professional (TIA Portal) | Yes; from V11 | |
Languages | ||
Online languages | ||
● Number of online/runtime languages | 32 | |
Project languages | ||
● Languages per project | 32 | |
Functionality under WinCC (TIA Portal) | ||
Libraries | Yes | |
Applications/options | ||
● Web browser | Yes | |
● Pocket Word | Yes | |
● Pocket Excel | Yes | |
● PDF Viewer | Yes | |
● Media Player | Yes | |
● SIMATIC WinCC Sm@rtServer | Yes | |
● SIMATIC WinCC Audit | Yes | |
Number of Visual Basic Scripts | Yes | |
Task planner | ||
● time-controlled | Yes | |
● task-controlled | Yes | |
Message system | ||
● Number of alarm classes | 32 | |
● Bit messages | ||
— Number of bit messages | 4 000 | |
● Analog messages | ||
— Number of analog messages | 200 | |
● S7 alarm number procedure | Yes | |
● System messages HMI | Yes | |
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, … ) | Yes | |
● Number of characters per message | 80 | |
● Number of process values per message | 8 | |
● Acknowledgment groups | Yes | |
● Message indicator | Yes | |
Recipe management | ||
● Number of recipes | 300 | |
● Data records per recipe | 500 | |
● Entries per data record | 1 000 | |
● Size of internal recipe memory | 2 Mbyte | |
● Recipe memory expandable | Yes | |
Variables | ||
● Number of variables per device | 2 048 | |
● Number of variables per screen | 400 | |
● Limit values | Yes | |
● Multiplexing | Yes | |
● Structures | Yes | |
● Arrays | Yes | |
Images | ||
● Number of configurable images | 500 | |
● Permanent window/default | Yes | |
● Global image | Yes | |
● Pop-up images | Yes | |
● Slide-in images | Yes | |
● Image selection by PLC | Yes | |
● Image number in the PLC | Yes | |
Image objects | ||
● Number of objects per image | 400 | |
● Text fields | Yes | |
● I/O fields | Yes | |
● Graphic I/O fields (graphics list) | Yes | |
● Symbolic I/O fields (text list) | Yes | |
● Date/time fields | Yes | |
● Switches | Yes | |
● Buttons | Yes | |
● Graphic display | Yes | |
● Icons | Yes | |
● Geometric objects | Yes | |
Complex image objects | ||
● Number of complex objects per screen | 20 | |
● Alarm view | Yes | |
● Trend view | Yes | |
● User view | Yes | |
● Status/control | Yes | |
● Sm@rtClient view | Yes | |
● Recipe view | Yes | |
● f(x) trend view | Yes | |
● System diagnostics view | Yes | |
● Media Player | Yes | |
● HTML browser | Yes | |
● PDF display | Yes | |
● IP camera display | Yes | |
● Bar graphs | Yes | |
● Sliders | Yes | |
● Pointer instruments | Yes | |
● Analog/digital clock | Yes | |
Lists | ||
● Number of text lists per project | 500 | |
● Number of entries per text list | 500 | |
● Number of graphics lists per project | 500 | |
● Number of entries per graphics list | 500 | |
Archiving | ||
● Number of archives per device | 50 | |
● Number of entries per archive | 20 000 | |
● Message archive | Yes | |
● Process value archive | Yes | |
● Archiving methods | ||
— Sequential archive | Yes | |
— Short-term archive | Yes | |
● Memory location | ||
— Memory card | Yes | |
— USB memory | Yes | |
— Ethernet | Yes | |
● Data storage format | ||
— CSV | Yes | |
— TXT | Yes | |
— RDB | Yes | |
Security | ||
● Number of user groups | 50 | |
● Number of user rights | 32 | |
● Number of users | 50 | |
● Password export/import | Yes | |
● SIMATIC Logon | Yes | |
Logging through printer | ||
● Alarms | Yes | |
● Report (shift log) | Yes | |
● Hardcopy | Yes | |
● Electronic print to file | Yes; PDF, HTML | |
Character sets | ||
● Keyboard fonts | ||
— US English | Yes | |
Transfer (upload/download) | ||
● MPI/PROFIBUS DP | Yes | |
● USB | Yes | |
● Ethernet | Yes | |
● using external storage medium | Yes | |
Process coupling | ||
● S7-1200 | Yes | |
● S7-1500 | Yes | |
● S7-200 | Yes | |
● S7-300/400 | Yes | |
● LOGO! | Yes | |
● WinAC | Yes | |
● SINUMERIK | Yes; with SINUMERIK option package | |
● SIMOTION | Yes | |
● Allen Bradley (EtherNet/IP) | Yes | |
● Allen Bradley (DF1) | Yes | |
● Mitsubishi (MC TCP/IP) | Yes | |
● Mitsubishi (FX) | Yes | |
● OMRON (FINS TCP) | No | |
● OMRON (LINK/Multilink) | Yes | |
● Modicon (Modbus TCP/IP) | Yes | |
● Modicon (Modbus) | Yes | |
● OPC UA Client | Yes | |
● OPC UA Server | Yes | |
Service tools/configuration aids | ||
● Backup/Restore manually | Yes | |
● Backup/Restore automatically | Yes | |
● Simulation | Yes | |
● Device switchover | Yes | |
Peripherals/Options | ||
Printer | Yes | |
SIMATIC HMI MM memory card: Multi Media Card | Yes; Up to 128 MB | |
SIMATIC HMI SD memory card: Secure Digital memory card | Yes; Up to 2 GB | |
SIMATIC HMI CF memory card Compact Flash Card | No | |
USB memory | Yes | |
SIMATIC IPC USB Flashdrive (USB stick) | Yes; Up to 16 GB | |
SIMATIC HMI USB stick | Yes; Up to 8 GB | |
Network camera | Yes | |
Mechanics/material | ||
Enclosure material (front) | ||
● Plastic | No | |
● Aluminum | No | |
● Stainless steel | Yes | |
Dimensions | ||
Width of the housing front | 214 mm | |
Height of housing front | 158 mm | |
Mounting cutout, width | 197 mm | |
Mounting cutout, height | 141 mm | |
Overall depth | 65 mm | |
Weights | ||
Weight (without packaging) | 1.9 kg | |
Weight (with packaging) | 2 kg |
Weight | 2.157 kg |
---|---|
Dimensions | 19.5 × 27.5 × 11.2 cm |