Contact Us:
sales@inosaki.com

SIMATIC ET 200SP – SIPLUS Interface Modules – Siemens

$ 193.38$ 199.98

SKU N/A Category

The IM 155-6 interface module is snapped directly onto the DIN rail (7.5 x 35 mm or 15 x 35 mm).

  • Optional labeling using light gray or yellow labeling strips. There is a choice of 2 materials:
    • Film strips on a roll with 500 strips, for thermal transfer roll printer
    • Card (180 g/m2), DIN A4 sheets with 100 strips each, for laser printer
  • Optional equipment marking using slide-in equipment labeling plates
  • Different connection types of the fieldbus by means of SIMATIC BusAdapter for PROFINET or MultiFieldbus interface modules in Standard function class or above
    • Under ambient conditions in accordance with SIMATIC standard using BA 2xRJ45 for connection via RJ45 plug
    • In the case of mechanical loading during operation and/or an increased EMC requirements BA 2xFC for direct connection of the PROFINET cable
    • For increased potential differences, BusAdapters with fiber-optic interface can be used. These are also available as hybrid variants with copper interface (integrated media converter). For larger distances, BusAdapters are also available with LC glass fiber-optic connections.
  • Cable
    • The High Feature interface modules can optionally be equipped with the system-integrated strain relief for the PROFINET cables.

Siemens SIPLUS Interface Modules ET 200SP Product Specifications:

Article number 6AG1155-6AA01-7BN0 6AG1155-6AU01-2CN0 6AG1155-6AU01-7CN0 6AG1155-6AU01-7BN0 6AG1155-6BA01-7CN0
SIPLUS ET 200SP IM155-6PN ST / BA SIPLUS ET 200SP IM155-6PN HF SIPLUS ET 200SP IM155-6PN HF SIPLUS ET 200SP IM155-6PN ST SIPLUS ET 200SP IM155-6DP HF
General information
Product type designation IM 155-6 PN ST IM 155-6 PN/2 HF IM 155-6 PN/2 HF IM 155-6 PN ST IM 155-6 DP HF
Firmware version
● FW update possible Yes Yes
Vendor identification (VendorID) 002AH
Device identifier (DeviceID) 0313H
Product function
● I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
● Module swapping during operation (hot swapping) Yes; Single hot swapping Yes; Multi-hot swapping Yes; Multi-hot swapping Yes; Single hot swapping Yes; Multi-hot swapping
● Isochronous mode No Yes Yes No No
● Tool changer Yes; Docking station and docking unit Yes; Docking station and docking unit
● Local coupling, IO data No No
● Local coupling, data records No No
Engineering with
● STEP 7 TIA Portal configurable/integrated from version see entry ID: 109746275 see entry ID: 109746275 see entry ID: 109746275 see entry ID: 109746275 see entry ID: 109746275
Configuration control
via dataset Yes Yes Yes Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V
Reverse polarity protection Yes Yes Yes Yes Yes
Short-circuit protection Yes Yes
Mains buffering
● Mains/voltage failure stored energy time 10 ms 10 ms 10 ms 10 ms 10 ms
Input current
Current consumption (rated value) 450 mA 450 mA
Current consumption, max. 550 mA 700 mA 700 mA 550 mA 335 mA
Inrush current, max. 3.7 A 4.5 A 4.5 A 3.7 A 1.6 A
I²t 0.09 A²·s 0.25 A²·s 0.25 A²·s 0.09 A²·s 0.038 A²·s
Power
Infeed power to the backplane bus 4.5 W 4.5 W
Power loss
Power loss, typ. 1.9 W 2.4 W 2.4 W 1.9 W 1.5 W
Address area
Address space per module
● Address space per module, max. 256 byte; per input / output 288 byte; For input and output data respectively 288 byte; For input and output data respectively 256 byte; per input / output 32 byte; per input / output
Address space per station
● Address space per station, max. 512 byte; Dependent on configuration 1 440 byte; Dependent on configuration 1 440 byte; Dependent on configuration 512 byte; Dependent on configuration 244 byte; per input / output
Hardware configuration
Rack
● Modules per rack, max. 32; + 16 ET 200AL modules 64; + 16 ET 200AL modules 64; + 16 ET 200AL modules 32; + 16 ET 200AL modules 32; + 16 ET 200AL modules
Submodules
● Number of submodules per station, max. 256 256 256 256
Time stamping
Accuracy 10 ms 10 ms
Interfaces
Number of PROFINET interfaces 1; 2 ports (switch) 1; 2 ports (switch) 1; 2 ports (switch) 1; 2 ports (switch)
Number of PROFIBUS interfaces 1
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; Pre-assembled BusAdapter BA 2x RJ45
● RS 485 Yes
● Number of ports 2 2; via BusAdapter 2; via BusAdapter 2
● integrated switch Yes Yes Yes Yes
● BusAdapter (PROFINET) Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC
● Output current of the interface, max. 90 mA
Protocols
● PROFINET IO Device Yes Yes Yes Yes
● PROFIBUS DP slave Yes
● Open IE communication Yes Yes Yes Yes
● Media redundancy Yes; PROFINET MRP Yes; PROFINET MRP Yes; PROFINET MRP Yes; PROFINET MRP
Interface types
RJ 45 (Ethernet)
● Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● 10 Mbps Yes; for Ethernet services No No Yes; for Ethernet services
● 100 Mbps Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● Autonegotiation Yes Yes Yes Yes
● Autocrossing Yes Yes Yes Yes
RS 485
● Transmission rate, max. 12 Mbit/s
Protocols
Number of connections
● Number of MtM communication relationships/connections, max. 16 16
PROFINET IO Device
Services
— IRT Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs
— PROFIenergy Yes Yes Yes Yes
— Prioritized startup Yes Yes Yes Yes
— Shared device Yes Yes Yes Yes
— Number of IO Controllers with shared device, max. 2 4 4 2
Redundancy mode
● PROFINET system redundancy (S2) No Yes; NAP S2 Yes; NAP S2 No
● Redundant PROFINET configuration (R1) No No
● H-Sync forwarding Yes Yes
Media redundancy
— MRP Yes Yes Yes Yes
— MRPD No No No No
Open IE communication
● TCP/IP Yes Yes Yes Yes No
● SNMP Yes Yes Yes Yes
● LLDP Yes Yes Yes Yes
PROFIBUS DP
Services
— SYNC capability Yes
— FREEZE capability Yes
— DPV0 Yes
— DPV1 Yes
Isochronous mode
Equidistance Yes Yes
shortest clock pulse 250 µs 250 µs
max. cycle 4 ms 4 ms
Bus cycle time (TDP), min. 250 µs 250 µs
Jitter, max. 1 µs 1 µs
Interrupts/diagnostics/status information
Status indicator Yes Yes Yes Yes Yes
Alarms Yes Yes Yes Yes Yes
Diagnostics function Yes Yes Yes Yes Yes
Diagnostics indication LED
● RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
● ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
● MAINT LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED
● Connection display LINK TX/RX Yes; 2x green link LEDs on BusAdapter Yes; 2x green link LEDs on BusAdapter Yes; 2x green link LEDs on BusAdapter Yes; 2x green link LEDs on BusAdapter
● Connection display DP Yes; green DP LED
Potential separation
between backplane bus and electronics No No No No No
between PROFIBUS DP and all other circuit components Yes
between PROFINET and all other circuits Yes; 1 500 V AC Yes Yes Yes; 1 500 V AC
between supply and all other circuits No No No No No
Permissible potential difference
between different circuits Safety extra low voltage SELV Safety extra low voltage SELV Safety extra low voltage SELV
Isolation
Isolation tested with 707 V DC (type test) 707 V DC (type test) 707 V DC (type test)
Standards, approvals, certificates
Network loading class 2 3 3 2
Security level According to Security Level 1 Test Cases V1.1.1 According to Security Level 1 Test Cases V1.1.1 According to Security Level 1 Test Cases V1.1.1 According to Security Level 1 Test Cases V1.1.1
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost)
● horizontal installation, max. 70 °C; = Tmax 60 °C; = Tmax 70 °C; = Tmax 70 °C; = Tmax 70 °C; = Tmax
● vertical installation, min. -40 °C; = Tmin -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin -40 °C; = Tmin (incl. condensation/frost)
● vertical installation, max. 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m 5 000 m 5 000 m 5 000 m 5 000 m
● Ambient air temperature-barometric pressure-altitude Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m) Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) // Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa (+2 000 m … +3 500 m) // Tmin … (Tmax -20 K) at 658 hPa … 540 hPa (+3 500 m … +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max. 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Resistance
Coolants and lubricants
— Resistant to commercially available coolants and lubricants Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3 Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3 Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6 Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
— to chemically active substances according to EN 60721-3-6 Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; * Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6 Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4 Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 * The supplied plug covers must remain in place over the unused interfaces during operation! * The supplied plug covers must remain in place over the unused interfaces during operation! * The supplied plug covers must remain in place over the unused interfaces during operation! * The supplied plug covers must remain in place over the unused interfaces during operation! * The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
● Coatings for printed circuit board assemblies acc. to EN 61086 Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
● Protection against fouling acc. to EN 60664-3 Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
● Military testing according to MIL-I-46058C, Amendment 7 Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
connection method / header
ET-Connection
● via BU/BA Send Yes; + 16 ET 200AL modules Yes; + 16 ET 200AL modules Yes; + 16 ET 200AL modules Yes; + 16 ET 200AL modules Yes; + 16 ET 200AL modules
Mechanics/material
Strain relief Yes; Optional Yes; Optional
Dimensions
Width 50 mm 50 mm 50 mm 50 mm 50 mm
Height 117 mm 117 mm 117 mm 117 mm 117 mm
Depth 74 mm 74 mm 74 mm 74 mm 74 mm
Weights
Weight, approx. 190 g; IM 155-6 PN BA with 2x RJ45 ports and server module 120 g; without BusAdapter 120 g; without BusAdapter 147 g; without BusAdapter 150 g

 

Additional information

Weight N/A
Dimensions N/A

Related Products

SCHNEIDER_TeSys GV2-Motor Circuit Breaker-Thermal-magnetic-0
M12
camera-gige-ueye-le-mb-boardlevel-5242-1
M16
PT 2
304 Hex Socket Head Cap Screws - M6
Select your currency