SIMATIC ET 200SP – IM 155-6PN Basic / Standard PROFINET Interface Modules – Siemens

$ 320.10$ 1,286.78

SKU: N/A

SIMATIC IM155-6PN Basic with PROFINET access

  • Max. 12 I/O modules, no PROFIsafe modules, with complete diagnostic support
  • Max. 32 bytes in each case for input and output data per module and per station
  • Data update time: typ.1 ms
  • PROFINET connection via 2 integrated RJ45 sockets (integrated 2-port switch)
  • Package includes server module

SIMATIC IM 155-6PN Standard with a PROFINET interface for SIMATIC BusAdapters

  • Two types of delivery:
    • As package with IM155-6PN ST, with pre-assembled BA 2xRJ45 BusAdapter, including server module
    • As package with IM155-6PN ST, without BusAdapter, including server module
  • Max. 32 I/O modules, also PROFIsafe modules, with complete diagnostic support
  • Expansion option with max. 16 modules from the ET 200AL series using the BU-Send BaseUnit and the BA-Send BusAdapter
  • Max. 256 bytes in each case for input and output data per module and max. 512 bytes per station (depending on configuration)
  • Data update time: typ.1 ms
  • Selection of the type of connection of the PROFINET by means of SIMATIC BusAdapter (BusAdapter for copper cables only)

Siemens Interface Modules ET 200SP Product Specifications:

Article number 6ES7155-6AR00-0AN0 6ES7155-6AA01-0BN0 6ES7155-6AU01-0BN0
ET 200SP, IM155-6PN Basic ET 200SP, IM155-6PN ST incl. BA 2xRJ45 ET 200SP, IM155-6PN ST
General information
Product type designation IM 155-6 PN BA IM 155-6 PN ST IM 155-6 PN ST
HW functional status from FS04 FS01 From FS03
Firmware version
● FW update possible Yes Yes Yes
Product function
● I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
● Module swapping during operation (hot swapping) Yes; Single hot swapping Yes; Single hot swapping Yes; Single hot swapping
● Isochronous mode No No No
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V13 SP1 V14 V14
● STEP 7 configurable/integrated from version V5.5 SP4 and higher V5.5 SP4 and higher V5.5 SP4 and higher
● PROFINET from GSD version/GSD revision V2.3 / – V2.3 / – V2.3 / –
Configuration control
via dataset Yes Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V
Reverse polarity protection Yes Yes Yes
Short-circuit protection Yes Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms 10 ms 10 ms
Input current
Current consumption (rated value) 450 mA 450 mA
Current consumption, max. 300 mA 550 mA 550 mA
Inrush current, max. 3.7 A 3.7 A
I²t 0.09 A²·s 0.09 A²·s 0.09 A²·s
Power
Infeed power to the backplane bus 4.5 W 4.5 W
Power loss
Power loss, typ. 1.8 W 1.9 W 1.9 W
Address area
Address space per module
● Address space per module, max. 32 byte; per input / output 256 byte; per input / output 256 byte; per input / output
Address space per station
● Address space per station, max. 32 byte; per input / output 512 byte; Dependent on configuration 512 byte; Dependent on configuration
Hardware configuration
Rack
● Quantity of operable ET 200SP modules, max. 12 32 32
● Quantity of operable ET 200AL modules, max. 0 16 16
Submodules
● Number of submodules per station, max. 256 256
Interfaces
Number of PROFINET interfaces 1; 2 ports (switch) 1; 2 ports (switch) 1; 2 ports (switch)
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; 2 integrated RJ45 ports Yes; Pre-assembled BusAdapter BA 2x RJ45
● Number of ports 2 2 2
● integrated switch Yes Yes Yes
● BusAdapter (PROFINET) No Yes; compatible BusAdapters: BA 2x RJ45, BA 2x FC, BA 2x M12 Yes; compatible BusAdapters: BA 2x RJ45, BA 2x FC, BA 2x M12
Protocols
● PROFINET IO Device Yes Yes Yes
● Open IE communication Yes Yes Yes
● Media redundancy Yes; PROFINET MRP Yes; PROFINET MRP Yes; PROFINET MRP
Interface types
RJ 45 (Ethernet)
● Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● 10 Mbps No
● 100 Mbps Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● Autonegotiation Yes Yes Yes
● Autocrossing Yes Yes Yes
Protocols
PROFINET IO Device
Services
— IRT No Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs
— PROFIenergy No Yes Yes
— Prioritized startup No Yes Yes
— Shared device No Yes Yes
— Number of IO Controllers with shared device, max. 2 2
Redundancy mode
● PROFINET system redundancy (S2) No No No
Media redundancy
— MRP Yes Yes Yes
— MRPD No No No
Open IE communication
● TCP/IP Yes Yes Yes
● SNMP Yes Yes Yes
● LLDP Yes Yes Yes
Isochronous mode
Equidistance No
Interrupts/diagnostics/status information
Status indicator Yes Yes Yes
Alarms Yes Yes Yes
Diagnostics function Yes Yes Yes
Diagnostics indication LED
● RUN LED Yes; green LED Yes; green LED Yes; green LED
● ERROR LED Yes; red LED Yes; red LED Yes; red LED
● MAINT LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED
● Connection display LINK TX/RX Yes; 2x green link LEDs on BusAdapter Yes; 2x green link LEDs on BusAdapter Yes; 2x green link LEDs on BusAdapter
Potential separation
between backplane bus and electronics No No No
between PROFINET and all other circuits Yes Yes; 1 500 V AC Yes; 1500 V AC (type test)
between supply and all other circuits No No No
Permissible potential difference
between different circuits Safety extra low voltage SELV Safety extra low voltage SELV
Isolation
Isolation tested with 707 V DC (type test) 707 V DC (type test)
Standards, approvals, certificates
Network loading class 2 2 2
Security level According to Security Level 1 Test Cases V1.1.1 According to Security Level 1 Test Cases V1.1.1
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -30 °C 0 °C 0 °C
● horizontal installation, max. 60 °C 60 °C 60 °C
● vertical installation, min. -30 °C 0 °C 0 °C
● vertical installation, max. 50 °C 50 °C 50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m
connection method / header
ET-Connection
● via BU/BA Send No Yes; + 16 ET 200AL modules Yes; + 16 ET 200AL modules
Dimensions
Width 35 mm 50 mm 50 mm
Height 117 mm 117 mm 117 mm
Depth 74 mm 74 mm 74 mm
Weights
Weight, approx. 125 g 190 g; IM 155-6 PN BA with 2x RJ45 ports and server module 147 g; without BusAdapter
Weight N/A
Dimensions N/A