Contact Us:
sales@inosaki.com

SIMATIC ET 200SP – Digital Fail-Safe Output Modules – Siemens Fail-Safe I/O Modules

$ 390.50$ 419.46

SKU N/A Category

The fail-safe ET 200SP modules can be used to implement the safety-related application requirements as an integrated part of the overall automation. The safety functions required for fail-safe operation are integrated in the modules. Communication with the fail-safe SIMATIC S7 CPUs is performed by means of PROFIsafe. The modules can be operated both in centralized and distributed configurations.

Siemens Fail-safe Modules SIMATIC ET 200SP Product Specifications:

Article number 6ES7136-6DB00-0CA0 6ES7136-6DC00-0CA0
ET 200SP, El-Mod., F-DQ 4xDC 24V/2A ET 200SP, F-DQ 8x 24VDC/0.5A PP
General information
Product type designation F-DQ 4×24 V DC/2A HF F-DQ 8×24 V DC/0.5 A PP HF
Firmware version
● FW update possible Yes
usable BaseUnits BU type A0 BU type A0
Color code for module-specific color identification plate CC02
Product function
● I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V12 V14 SP1 with HSP 202
● STEP 7 configurable/integrated from version V5.5 SP3 / – V5.5 SP4 HF5
● PROFINET from GSD version/GSD revision V2.31 V2.31
Supply voltage
Rated value (DC) 24 V 24 V
permissible range, lower limit (DC) 20.4 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V
Reverse polarity protection Yes Yes
power supply according to NEC Class 2 required No No
Input current
Current consumption (rated value) 75 mA; without load 75 mA; without load
Current consumption, max. 21 mA; From the backplane bus 21 mA; From the backplane bus
output voltage / header
Rated value (DC) 24 V 24 V
Power
Power available from the backplane bus 70 mW 70 mW
Power loss
Power loss, typ. 4 W 3 W
Address area
Address space per module
● Inputs 5 byte 6 byte; 5 bytes non-RIOforFA; 6 bytes RIOforFA
● Outputs 5 byte 6 byte; 5 bytes non-RIOforFA; 6 bytes RIOforFA
Hardware configuration
Automatic encoding Yes Yes
● Electronic coding element type F Yes Yes
Digital outputs
Type of digital output Transistor Transistor
Number of digital outputs 4 8
Digital outputs, parameterizable Yes Yes
Short-circuit protection Yes Yes
● Response threshold, typ. > 3.3 A Min. 0.7 A
Open-circuit detection Yes No
● Response threshold, typ. 8 mA
Overload protection Yes
● Response threshold, typ. 2.9 A
Limitation of inductive shutdown voltage to Typ. -2x 47 V Typ. -39 V
Controlling a digital input Yes
Switching capacity of the outputs
● with resistive load, max. 2 A 0.5 A
● on lamp load, max. 10 W 2 W
Load resistance range
● lower limit 12 Ω 48 Ω
● upper limit 2 000 Ω 12 000 Ω
Output voltage
● for signal “1”, min. 24 V; L+ (-0.5 V) 24 V; L+ (-0.5 V)
Output current
● for signal “1” rated value 2 A 0.5 A
● for signal “0” residual current, max. 0.5 mA 0.5 mA
Switching frequency
● with resistive load, max. 30 Hz; Symmetrical 30 Hz; Symmetrical
● with inductive load, max. 0.1 Hz; according to IEC 60947-5-1, DC-13, symmetrical 0.1 Hz; according to IEC 60947-5-1, DC-13, symmetrical
● with capacitive load, max. 2 Hz; Symmetrical
● on lamp load, max. 10 Hz; Symmetrical 10 Hz; Symmetrical
Total current of the outputs
● Current per channel, max. 2 A; note derating data in the manual 0.5 A; note derating data in the manual
● Current per module, max. 6 A; note derating data in the manual 3 A; note derating data in the manual
Total current of the outputs (per module)
horizontal installation
— up to 40 °C, max. 3 A
— up to 50 °C, max. 2.5 A
— up to 60 °C, max. 2 A
vertical installation
— up to 50 °C, max. 2 A
Cable length
● shielded, max. 1 000 m 100 m
● unshielded, max. 500 m 100 m
Interrupts/diagnostics/status information
Diagnostics function Yes Yes
Substitute values connectable No No
Alarms
● Diagnostic alarm Yes Yes
Diagnostics indication LED
● RUN LED Yes; green LED Yes; green LED
● ERROR LED Yes; red LED Yes; red LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED Yes; green PWR LED
● Channel status display Yes; green LED Yes; green LED
● for channel diagnostics Yes; red LED Yes; red LED
● for module diagnostics Yes; green/red DIAG LED Yes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channels No No
● between the channels and backplane bus Yes Yes
● between the channels and the power supply of the electronics No No
Isolation
Isolation tested with 707 V DC (type test) 707 V DC (type test)
Standards, approvals, certificates
Suitable for safety functions Yes Yes
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 PLe PLe
● Category according to ISO 13849-1 Cat. 4
● SIL acc. to IEC 61508 SIL 3 SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL2 < 2.00E-04
— Low demand mode: PFDavg in accordance with SIL3 < 2.00E-05 < 6.00E-05
— High demand/continuous mode: PFH in accordance with SIL2 < 1.00E-08 1/h
— High demand/continuous mode: PFH in accordance with SIL3 < 1.00E-09 1/h < 2.00E-09 1/h
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C 0 °C
● horizontal installation, max. 60 °C 60 °C
● vertical installation, min. 0 °C 0 °C
● vertical installation, max. 50 °C 50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 4 000 m; Restrictions for installation altitudes > 2 000 m, see manual 4 000 m; with derating
Dimensions
Width 15 mm 15 mm
Height 73 mm 73 mm
Depth 58 mm 58 mm
Weights
Weight, approx. 57 g 48 g

Additional information

Weight N/A
Dimensions N/A

Related Products

Siemens_3RV6_3 Poles Circuit Breaker With Transverse AUX
ST 6-PE -Ground modular terminal block - 3031500 -Phoenix Contact
ER-XC02
PSN17-8DN-F
Festo_Proximity sensors_SMT-8M-A-PS-24V-E-1-M8D_574333 09
Trachea Quick-Plug Connector, All Copper Nickel-Plated G Thread
Select your currency