$ 289.27 – $ 310.95
The pneumatic interface is designed for an original FESTO valve terminal. ET 200pro can then also be used for applications requiring flexible pneumatics.
A wide variety of valve functions from the standard FESTO spectrum and a choice of flow rates facilitate an extensive range of applications.
CPV 10 or CPV 14 FESTO valve terminals can be used and are available from FESTO.
Article number | 6ES7148-4EA00-0AA0 | 6ES7148-4EB00-0AA0 |
ET200PRO, 16DO,Pneumatic Interface CPV10 | ET200PRO, 16DO,Pneumatic Interface CPV14 | |
Supply voltage | ||
Load voltage 2L+ | ||
● Rated value (DC) | 24 V | 24 V |
● Short-circuit protection | Yes | Yes |
● Reverse polarity protection | Yes | Yes |
Input current | ||
from load voltage 2L+, max. | 300 mA; Including valves | 370 mA; Including valves |
from backplane bus 3.3 V DC, max. | 25 mA | 25 mA |
Power loss | ||
Power loss, typ. | 2.6 W | 3.7 W |
Address area | ||
Address space per module | ||
● Address space per module, max. | 2 byte | 2 byte |
Digital outputs | ||
Number of digital outputs | 16 | 16 |
Load resistance range | ||
● lower limit | 500 Ω | 500 Ω |
● upper limit | 2 500 Ω | 2 500 Ω |
Output current | ||
● for signal “1” rated value | 12 mA | 16 mA |
● for signal “1” permissible range, min. | 11 mA | 14 mA |
● for signal “1” permissible range, max. | 15 mA | 20 mA |
Switching frequency | ||
● with inductive load, max. | 25 Hz | 20 Hz |
Total current of the outputs (per group) | ||
all mounting positions | ||
— up to 55 °C, max. | 250 mA; only up to 50 °C, limited by valves | 330 mA; only up to 50 °C, limited by valves |
Interrupts/diagnostics/status information | ||
Diagnostics function | Yes | Yes |
Alarms | ||
● Diagnostic alarm | Yes | Yes |
Diagnoses | ||
● Diagnostic information readable | Yes | Yes |
Diagnostics indication LED | ||
● Group error SF (red) | Yes | Yes |
● Status indicator digital output (green) | Yes | Yes |
Pneumatics | ||
Number of connectable valves, max. | 16 | 16 |
permissible working pressure, min. | 3 bar | 3 bar |
permissible working pressure, max. | 8 bar | 8 bar |
Rated flow rate | 400 l/min | 800 l/min |
Valve switching times from “0” to “1” | 17 ms | 24 ms |
Valve switching times from “1” to “0” | 25 ms | 30 ms |
Parameter | ||
Remark | Diagnosis load voltage 2L+ | Diagnosis load voltage 2L+ |
Response to CPU/master STOP | No | |
Potential separation | ||
between backplane bus and all other circuit components | Yes | Yes |
Potential separation digital outputs | ||
● between the channels and backplane bus | Yes | Yes |
Isolation | ||
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) |
Standards, approvals, certificates | ||
Suitable for safety-related tripping of standard modules | Yes | Yes |
Highest safety class achievable for safety-related tripping of standard modules | ||
● Performance level according to ISO 13849-1 | PL d | PL d |
● Category according to ISO 13849-1 | Cat. 3 | Cat. 3 |
● SIL acc. to IEC 62061 | SIL 2 | SIL 2 |
Dimensions | ||
Width | 90 mm | 120 mm |
Height | 130 mm | 152 mm |
Depth | 47 mm | 47 mm |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)