$ 282.48
The 4 IO-LINK HF electronic module facilitates data exchange with up to 4 IO-Link devices.
Since IO-Link is compatible with standard sensors, commercially available sensors in accordance with IEC 61131 Type 1 can also be operated on the IO-Link master.
Article number | 6ES7147-4JD00-0AB0 | |
ET200pro, EM 4 IO-Link HF | ||
Supply voltage | ||
Rated value (DC) | 24 V | |
Reverse polarity protection | Yes | |
Load voltage 2L+ | ||
● Rated value (DC) | 24 V | |
● Short-circuit protection | Yes | |
● Reverse polarity protection | Yes; against destruction; load increasing | |
Input current | ||
from supply voltage 1L+, max. | 40 mA | |
from load voltage 2L+ (without load), max. | 20 mA | |
from backplane bus 3.3 V DC, max. | 20 mA | |
Encoder supply | ||
Number of outputs | 4 | |
Short-circuit protection | Yes; per module, electronic | |
Output current | ||
● up to 55 °C, max. | 2 A | |
Power loss | ||
Power loss, typ. | 2.6 W | |
IO-Link | ||
Number of ports | 4 | |
● of which simultaneously controllable | 4 | |
IO-Link protocol 1.0 | Yes | |
IO-Link protocol 1.1 | Yes | |
Transmission rate | 4.8 kBaud (COM1); 38.4 kBaud (COM2), 230.4 kBaud (COM3) | |
Size of process data, input per port | 32 byte | |
Size of process data, input per module | 32 byte | |
Size of process data, output per port | 32 byte | |
Size of process data, output per module | 32 byte | |
Memory size for device parameter | 2 kbyte; for each port | |
Master backup | Possible with function block IO_LINK_MASTER | |
Configuration without S7-PCT | Possible; autostart/manual function | |
Cable length unshielded, max. | 20 m | |
Operating modes | ||
● IO-Link | Yes | |
● DI | Yes | |
● DQ | Yes; max. 100 mA | |
Connection of IO-Link devices | ||
● Port type A | Yes; via 3-core cable | |
● Port type B | Yes; Additional device supply: for X1 and X2 max. 2 A in total, for X3 and X4 max. 2 A in total | |
Interrupts/diagnostics/status information | ||
Diagnostics function | Yes | |
Alarms | ||
● Diagnostic alarm | Yes | |
Diagnoses | ||
● Diagnostic information readable | Yes | |
● Wire-break | Yes; channel by channel | |
● Short-circuit | Yes; channel by channel | |
Diagnostics indication LED | ||
● Channel status display | Yes; One green LED for channel status Qn (SIO mode) and port status IO-Ln (IO-Link mode) | |
● Group error SF (red) | Yes | |
● Channel fault indicator F (red) | Yes; combined with the IO-Link port status | |
Potential separation | ||
between the load voltages | Yes | |
between backplane bus and all other circuit components | Yes | |
Potential separation channels | ||
● between the channels | No | |
Isolation | ||
Isolation tested with | 707 V DC (type test) | |
Degree and class of protection | ||
IP degree of protection | IP65/67 | |
Standards, approvals, certificates | ||
Suitable for safety-related tripping of standard modules | No | |
Dimensions | ||
Width | 45 mm | |
Height | 130 mm | |
Depth | 35 mm | |
Weights | ||
Weight, approx. | 150 g |
Weight | 0.181 kg |
---|---|
Dimensions | 7.3 × 13.9 × 6.8 cm |