SIMATIC ET 200pro – IM 154-8 Fail-Safe PN/DP CPU – Siemens PLC

USD $ 1,041.70USD $ 4,352.29

SKU: N/A

The intelligent interface module IM 154-8 F PN/DP CPU features integrated PLC functionality. The functions included correspond to those of the S7-300 CPU 315F PN/DP.

The IM 154-8 F PN/DP CPU can be used simultaneously as an IO Controller and as an I-Device on PROFINET via the integral PROFINET interface.

Siemens PLC ET 200pro Product Specifications:

Article number 6ES7154-8FB01-0AB0 6ES7154-8FX00-0AB0
ET 200pro: IM 154-8F PN/DP CPU, 512KB ET 200pro: IM 154-8FX PN/DP CPU, 1,5MB
General information
HW functional status 1 1
Firmware version V3.2 V3.2
Product function
● Isochronous mode Yes; Via PROFIBUS DP or PROFINET interface Yes; Via PROFIBUS DP or PROFINET interface
Engineering with
● Programming package STEP 7 V5.5 or higher, Distributed Safety V5.4 SP4 As of STEP 7 V5.5 with HSP 222 + Distributed Safety V5.4 SP4
Supply voltage
Rated value (DC) 24 V 24 V
external protection for power supply lines (recommendation) MCB 24 V DC / 16 A with tripping characteristic Type B and C (see ET 200pro manual) MCB 24 V DC / 16 A with tripping characteristic Type B and C (see ET 200pro manual)
Load voltage L+
● Rated value (DC) 24 V 24 V
● permissible range, lower limit (DC) 20.4 V 20.4 V
● permissible range, upper limit (DC) 28.8 V 28.8 V
● Reverse polarity protection Yes Yes
Input current
Current consumption, typ. 350 mA 350 mA
Current consumption (in no-load operation), typ. 250 mA; Typical, current consumption for CPU in STOP state 250 mA; Typical, current consumption for CPU in STOP state
Inrush current, typ. 2 A 2 A
I²t 0.25 A²·s; Typical 0.25 A²·s; Typical
Power loss
Power loss, typ. 8.5 W 8.5 W
Memory
Work memory
● integrated 512 kbyte 1 536 kbyte
● expandable No No
Load memory
● Plug-in (MMC) Yes Yes
● Plug-in (MMC), max. 8 Mbyte 8 Mbyte
● Data management on MMC (after last programming), min. 10 y 10 y
Backup
● present Yes; Guaranteed by MMC (maintenance-free) Yes; Guaranteed by MMC (maintenance-free)
● without battery Yes; Program and data Yes; Program and data
CPU processing times
for bit operations, typ. 0.05 µs 0.025 µs
for word operations, typ. 0.09 µs 0.03 µs
for fixed point arithmetic, typ. 0.12 µs 0.04 µs
for floating point arithmetic, typ. 0.45 µs 0.16 µs
CPU-blocks
Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
● Number, max. 1 024; Number range: 1 to 16000 1 024; Number range: 1 to 16000
● Size, max. 64 kbyte 64 kbyte
FB
● Number, max. 1 024; Number range: 0 to 7999 1 024; Number range: 0 to 7999
● Size, max. 64 kbyte 64 kbyte
FC
● Number, max. 1 024; Number range: 0 to 7999 1 024; Number range: 0 to 7999
● Size, max. 64 kbyte 64 kbyte
OB
● Size, max. 64 kbyte 64 kbyte
● Number of free cycle OBs 1; OB 1 1; OB 1
● Number of time alarm OBs 1; OB 10 1; OB 10
● Number of delay alarm OBs 2; OB 20, 21 2; OB 20, 21
● Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35 4; OB 32, 33, 34, 35
● Number of process alarm OBs 1; OB 40 1; OB 40
● Number of DPV1 alarm OBs 3; OB 55, 56, 57 3; OB 55, 56, 57
● Number of isochronous mode OBs 1; OB 61 1; OB 61
● Number of startup OBs 1; OB 100 1; OB 100
● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO) 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO)
● Number of synchronous error OBs 2; OB 121, 122 2; OB 121, 122
Nesting depth
● per priority class 16 16
● additional within an error OB 4 4
Counters, timers and their retentivity
S7 counter
● Number 256 256
Retentivity
— adjustable Yes Yes
— lower limit 0 0
— upper limit 255 255
— preset Z 0 to Z 7 Z 0 to Z 7
Counting range
— adjustable Yes Yes
— lower limit 0 0
— upper limit 999 999
IEC counter
● present Yes Yes
● Type SFB SFB
● Number Unlimited (limited only by RAM capacity) Unlimited (limited only by RAM capacity)
S7 times
● Number 256 256
Retentivity
— adjustable Yes Yes
— lower limit 0 0
— upper limit 255 255
— preset No retentivity No retentivity
Time range
— lower limit 10 ms 10 ms
— upper limit 9 990 s 9 990 s
IEC timer
● present Yes Yes
● Type SFB SFB
● Number Unlimited (limited only by RAM capacity) Unlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 128 kbyte 128 kbyte
Flag
● Size, max. 2 048 byte 2 048 byte
● Retentivity available Yes; MB 0 to MB 2 047 Yes; MB 0 to MB 2 047
● Retentivity preset MB 0 to MB 15 MB 0 to MB 15
● Number of clock memories 8 8
Data blocks
● Retentivity adjustable Yes; via non-retain property on DB Yes; via non-retain property on DB
● Retentivity preset Yes Yes
Local data
● per priority class, max. 32 768 byte; Max. 2048 bytes per block 32 768 byte; Max. 2048 bytes per block
Address area
I/O address area
● Inputs 2 048 byte 2 048 byte
● Outputs 2 048 byte 2 048 byte
of which distributed
— Inputs 2 048 byte 2 048 byte
— Outputs 2 048 byte 2 048 byte
Process image
● Inputs, adjustable 2 048 byte 2 048 byte
● Outputs, adjustable 2 048 byte 2 048 byte
● Inputs, default 128 byte 128 byte
● Outputs, default 128 byte 128 byte
Subprocess images
● Number of subprocess images, max. 1; With PROFINET IO, the length of the user data is limited to 1600 bytes 1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
● Inputs 16 384 16 384
— of which central 128 128
● Outputs 16 384 16 384
— of which central 64 64
Analog channels
● Inputs 1 024 1 024
— of which central 64 64
● Outputs 1 024 1 024
— of which central 64 64
Hardware configuration
Integrated power supply No No
Number of DP masters
● integrated 1 1
Rack
● Racks, max. 1 1
● Modules per rack, max. 16; Expansion width max. 1 m 16; Expansion width max. 1 m
Time of day
Clock
● Hardware clock (real-time) Yes Yes
● retentive and synchronizable Yes Yes
● Backup time 6 wk; At 40 °C ambient temperature 6 wk; At 40 °C ambient temperature
● Deviation per day, max. 10 s; Typ.: 2 s 10 s; Typ.: 2 s
Operating hours counter
● Number 1 1
● Number/Number range 0 0
● Range of values 0 to 2^31 hours (when using SFC 101) 0 to 2^31 hours (when using SFC 101)
● Granularity 1 h 1 h
● retentive Yes; Must be restarted at each restart Yes; Must be restarted at each restart
Clock synchronization
● supported Yes Yes
● to MPI, master Yes Yes
● to MPI, slave Yes Yes
● to DP, master Yes; With DP slave only slave clock Yes; With DP slave only slave clock
● to DP, slave Yes Yes
● on Ethernet via NTP Yes; As client Yes; As client
1. Interface
Interface type Integrated RS 485 interface Integrated RS 485 interface
Isolated Yes Yes
Interface types
● RS 485 Yes Yes
● Output current of the interface, max. May only be used for external terminating resistor May only be used for external terminating resistor
● Design of the connection 2x M12 B-coded 2x M12 B-coded
Protocols
● MPI Yes Yes
● PROFIBUS DP master Yes Yes
● PROFIBUS DP slave Yes Yes
● Point-to-point connection No No
MPI
● Transmission rate, max. 12 Mbit/s 12 Mbit/s
Services
— PG/OP communication Yes Yes
— Routing Yes Yes
— Global data communication Yes Yes
— S7 basic communication Yes Yes
— S7 communication Yes Yes
— S7 communication, as client No No
— S7 communication, as server Yes Yes
PROFIBUS DP master
● Transmission rate, max. 12 Mbit/s 12 Mbit/s
● Number of DP slaves, max. 124 124
Services
— PG/OP communication Yes Yes
— Routing Yes Yes
— Global data communication No No
— S7 basic communication Yes; I blocks only Yes; I blocks only
— S7 communication Yes Yes
— S7 communication, as client No No
— S7 communication, as server Yes; Connection configured on one side only Yes; Connection configured on one side only
— Equidistance Yes Yes
— Isochronous mode Yes; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously) Yes; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously)
— SYNC/FREEZE Yes Yes
— Activation/deactivation of DP slaves Yes Yes
— Direct data exchange (slave-to-slave communication) Yes; as subscriber Yes; as subscriber
— DPV1 Yes Yes
Address area
— Inputs, max. 2 048 byte 2 048 byte
— Outputs, max. 2 048 byte 2 048 byte
User data per DP slave
— Inputs, max. 244 byte 244 byte
— Outputs, max. 244 byte 244 byte
PROFIBUS DP slave
● Transmission rate, max. 12 Mbit/s 12 Mbit/s
● automatic baud rate search Yes; only with passive interface Yes; only with passive interface
● Address area, max. 32 32
● User data per address area, max. 32 byte 32 byte
Services
— Routing Yes; with interface active Yes; with interface active
— Global data communication No No
— S7 basic communication No No
— S7 communication Yes Yes
— S7 communication, as client No No
— S7 communication, as server Yes; Connection configured on one side only Yes; Connection configured on one side only
— Direct data exchange (slave-to-slave communication) Yes Yes
— DPV1 No No
Transfer memory
— Inputs 244 byte 244 byte
— Outputs 244 byte 244 byte
2. Interface
Interface type PROFINET PROFINET
Isolated Yes; Galvanic isolation for P3 is implemented in IM154-8, for P1 and P2 in CM Yes; Galvanic isolation for P3 is implemented in IM154-8, for P1 and P2 in CM
automatic detection of transmission rate Yes; 10/100 Mbit/s Yes; 10/100 Mbit/s
Autonegotiation Yes Yes
Autocrossing Yes Yes
Change of IP address at runtime, supported Yes Yes
Interface types
● Number of ports 3 3
● integrated switch Yes Yes
● Design of the connection Ethernet (2x M12 D-coded; 1x RJ45) Ethernet (2x M12 D-coded; 1x RJ45)
Protocols
● MPI No No
● PROFINET IO Controller Yes; Also simultaneously with IO-Device functionality Yes; Also simultaneously with IO-Device functionality
● PROFINET IO Device Yes; Also simultaneously with IO Controller functionality Yes; Also simultaneously with IO Controller functionality
● PROFINET CBA Yes Yes
● PROFIBUS DP master No No
● PROFIBUS DP slave No No
● Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP Yes; Via TCP/IP, ISO on TCP, and UDP
● Web server Yes Yes
● Media redundancy Yes Yes
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s 100 Mbit/s
Services
— PG/OP communication Yes Yes
— Routing Yes Yes
— S7 communication Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32 Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
— Isochronous mode Yes; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously) Yes; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously)
— IRT Yes Yes
— Prioritized startup Yes Yes
— Number of IO devices with prioritized startup, max. 32 32
— Number of connectable IO Devices, max. 128 128
— Of which IO devices with IRT, max. 64 64
— of which in line, max. 64 64
— Number of IO Devices with IRT and the option “high flexibility” 128 128
— of which in line, max. 61 61
— Number of connectable IO Devices for RT, max. 128 128
— of which in line, max. 128 128
— Activation/deactivation of IO Devices Yes Yes
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8 8
— IO Devices changing during operation (partner ports), supported Yes Yes
— Number of IO Devices per tool, max. 8 8
— Device replacement without swap medium Yes Yes
— Send cycles 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with “high flexibility” option) 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with “high flexibility” option)
— Updating time 250 µs to 512 ms (depending on the operating mode, see “IM 154-8 CPU Interface Module” operating instructions for more details) 250 µs to 512 ms (depending on the operating mode, see “IM 154-8 CPU Interface Module” operating instructions for more details)
Address area
— Inputs, max. 2 048 byte 2 048 byte
— Outputs, max. 2 048 byte 2 048 byte
— User data consistency, max. 1 024 byte 1 024 byte
PROFINET IO Device
Services
— PG/OP communication Yes Yes
— Routing Yes Yes
— S7 communication Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32 Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
— Isochronous mode No No
— IRT Yes Yes
— PROFIenergy Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
— Shared device Yes Yes
— Number of IO Controllers with shared device, max. 2 2
Transfer memory
— Inputs, max. 1 440 byte; Per IO Controller with shared device 1 440 byte; Per IO Controller with shared device
— Outputs, max. 1 440 byte; Per IO Controller with shared device 1 440 byte; Per IO Controller with shared device
Submodules
— Number, max. 64 64
— User data per submodule, max. 1 024 byte 1 024 byte
PROFINET CBA
● acyclic transmission Yes Yes
● cyclic transmission Yes Yes
Open IE communication
● Number of connections, max. 8 8
● Local port numbers used at the system end 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
● Keep-alive function, supported Yes Yes
Protocols
Redundancy mode
Media redundancy
— Switchover time on line break, typ. 200 ms; PROFINET MRP 200 ms; PROFINET MRP
— Number of stations in the ring, max. 50 50
SIMATIC communication
● S7 routing Yes Yes
Open IE communication
● TCP/IP Yes; via integrated PROFINET interface and loadable FBs Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8 8
— Data length, max. 32 768 byte; 1 460 bytes with connection type 01H; 32 768 bytes with connection type 11H 32 768 byte; 1 460 bytes with connection type 01H; 32 768 bytes with connection type 11H
— several passive connections per port, supported Yes Yes
● ISO-on-TCP (RFC1006) Yes Yes
— Number of connections, max. 8 8
— Data length, max. 32 768 byte 32 768 byte
● UDP Yes Yes
— Number of connections, max. 8 8
— Data length, max. 1 472 byte 1 472 byte
Web server
● supported Yes Yes
● User-defined websites Yes Yes
● Number of HTTP clients 5 5
communication functions / header
PG/OP communication Yes Yes
Global data communication
● supported Yes Yes
● Number of GD loops, max. 8 8
● Number of GD packets, max. 8 8
● Number of GD packets, transmitter, max. 8 8
● Number of GD packets, receiver, max. 8 8
● Size of GD packets, max. 22 byte 22 byte
● Size of GD packet (of which consistent), max. 22 byte 22 byte
S7 basic communication
● supported Yes Yes
● User data per job, max. 76 byte 76 byte
● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● supported Yes Yes
● as server Yes Yes
● as client Yes; via integrated PROFINET interface and loadable FBs Yes; via integrated PROFINET interface and loadable FBs
● User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
communication functions / PROFINET CBA (with set target communication load) / header
● Setpoint for the CPU communication load 50 % 50 %
● number of remote connection partners / with PROFINET CBA 32 32
● number of technological functions / with PROFINET CBA / for master or slave 30 30
● number of connections / with PROFINET CBA / for master or slave / total 1 000 1 000
● data volume / of the input variables / with PROFINET CBA / for master or slave 4 000 byte 4 000 byte
● data volume / of the output variables / with PROFINET CBA / for master or slave 4 000 byte 4 000 byte
● number of internal and PROFIBUS interconnections / with PROFINET CBA / maximum 500 500
● data volume / of internal and PROFIBUS interconnections / with PROFINET CBA / for master or slave 4 000 byte 4 000 byte
● data volume / with PROFINET CBA / per connection / maximum 1 400 byte 1 400 byte
performance data / PROFINET CBA / remote interconnection / with acyclic transfer / header
— update time / of the remote interconnections / in the case of acyclic transmission / with PROFINET CBA 500 ms 500 ms
— number of remote connections to input variables / in the case of acyclic transmission / with PROFINET CBA / maximum 100 100
— number of remote connections to output variables / in the case of acyclic transmission / with PROFINET CBA / maximum 100 100
— data volume / as user data for remote interconnections with input variables / in the case of acyclic transmission / with PROFINET CBA 2 000 byte 2 000 byte
— data volume / as user data for remote interconnections with output variables / in the case of acyclic transmission / with PROFINET CBA 2 000 byte 2 000 byte
— data volume / as user data for remote interconnections / in the case of acyclic transmission / with PROFINET CBA / per connection / maximum 1 400 byte 1 400 byte
performance data / PROFINET CBA / remote interconnection / with cyclic transfer / header
— update time / of the remote interconnections / with cyclical transfer / with PROFINET CBA 1 ms 1 ms
— number of remote connections to input variables / with PROFINET CBA / with cyclic transfer / maximum 200 200
— number of remote connections to output variables / with cyclical transfer / with PROFINET CBA / maximum 200 200
— data volume / as user data for remote interconnections with input variables / with cyclical transfer / with PROFINET CBA / maximum 2 000 byte 2 000 byte
— data volume / as user data for remote interconnections with output variables / with cyclical transfer / with PROFINET CBA / maximum 2 000 byte 2 000 byte
— data volume / as user data for remote interconnections / with cyclical transfer / with PROFINET CBA / per connection / maximum 450 byte 450 byte
performance data / PROFINET CBA / HMI variables via PROFINET / acyclic / header
— number of connectable HMI stations / for HMI variables / in the case of acyclic transmission / with PROFINET CBA 3; 2x PN OPC/1x iMap 3; 2x PN OPC/1x iMap
— update time / of the HMI variables / in the case of acyclic transmission / with PROFINET CBA 500 ms 500 ms
— number of HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum 200 200
— data volume / as user data for HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum 2 000 byte 2 000 byte
performance data / PROFINET CBA / PROFIBUS proxy functionality / header
— product function / with PROFINET CBA / PROFIBUS proxy functionality Yes Yes
— number of coupled PROFIBUS devices / with PROFIBUS functionality 16 16
— data volume / with PROFIBUS proxy functionality / with PROFINET CBA / per connection / maximum 240 byte; Slave-dependent 240 byte; Slave-dependent
Number of connections
● overall 16 16
● usable for PG communication 15 15
— reserved for PG communication 1 1
— adjustable for PG communication, min. 1 1
— adjustable for PG communication, max. 15 15
● usable for OP communication 15 15
— reserved for OP communication 1 1
— adjustable for OP communication, min. 1 1
— adjustable for OP communication, max. 15 15
● usable for S7 basic communication 14 14
— reserved for S7 basic communication 0 0
— adjustable for S7 basic communication, min. 0 0
— adjustable for S7 basic communication, max. 14 14
● usable for routing X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max. X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions
Number of login stations for message functions, max. 16; Depending on the configured connections for PG/OP and S7 basic communication 16; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messages Yes Yes
simultaneously active Alarm-S blocks, max. 300 300
Test commissioning functions
Status block Yes; Up to 2 simultaneously Yes; Up to 2 simultaneously
Single step Yes Yes
Number of breakpoints 4 4
Status/control
● Status/control variable Yes Yes
● Variables Inputs, outputs, memory bits, DB, times, counters Inputs, outputs, memory bits, DB, times, counters
● Number of variables, max. 30 30
— of which status variables, max. 30 30
— of which control variables, max. 14 14
Forcing
● Forcing Yes Yes
● Forcing, variables I/O I/O
● Number of variables, max. 10 10
Diagnostic buffer
● present Yes Yes
● Number of entries, max. 500; Only the last 100 entries are retentive at power on/off 500; Only the last 100 entries are retentive at power on/off
— adjustable No No
— preset 10 10
Potential separation
between backplane bus and electronics No No
between backplane bus and all other circuit components Yes Yes
between supply and all other circuits Yes Yes
Isolation
Isolation tested with In general, 707 V DC (type test), Ethernet interface 1 500 V AC (for P1 and P2 on CM, for P3 on IM) In general, 707 V DC (type test), Ethernet interface 1 500 V AC (for P1 and P2 on CM, for P3 on IM)
Degree and class of protection
IP degree of protection IP65/67 IP65/67
Standards, approvals, certificates
CE mark Yes Yes
CSA approval No No
cULus Yes Yes
FM approval No No
RCM (formerly C-TICK) Yes Yes
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 PLe PLe
● SIL acc. to IEC 61508 SIL 3 SIL 3
configuration / header
Configuration software
● STEP 7 Yes; V5.5 or higher Yes; V5.5 or higher
configuration / programming / header
● Command set see instruction list see instruction list
● Nesting levels 8 8
● System functions (SFC) see instruction list see instruction list
● System function blocks (SFB) see instruction list see instruction list
Programming language
— LAD Yes Yes
— FBD Yes Yes
— STL Yes Yes
— SCL Yes Yes
— CFC Yes Yes
— GRAPH Yes Yes
— HiGraph® Yes Yes
Know-how protection
● User program protection/password protection Yes Yes
● Block encryption Yes; With S7 block Privacy Yes; With S7 block Privacy
Dimensions
Width 135 mm 135 mm
Height 130 mm 130 mm
Depth 65 mm; 60 mm without cover for RJ45 socket; 65 mm with cover for RJ45 socket 65 mm; 60 mm without cover for RJ45 socket; 65 mm with cover for RJ45 socket
Weights
Weight, approx. 720 g 720 g
Weight N/A
Dimensions N/A