SIMATIC ET 200MP – PROFINET IO Device Interface Module IM 155-5 – Siemens Interface Modules

$ 399.52$ 774.62

SKU: N/A

The IM 155-5 PN interface module enables the connection of ET 200MP to PROFINET and handles the communication between the modules and the higher-level I/O controller autonomously.

Siemens Interface Modules ET 200MP Product Specifications:

Article number 6ES7155-5AA00-0AA0 6ES7155-5AA00-0AC0 6ES7155-5AA01-0AB0
ET 200MP, IM 155-5 PN BA ET 200MP, IM 155-5 PN HF ET 200MP, IM 155-5 PN ST
General information
Product type designation IM 155-5 PN BA IM 155-5 PN HF IM 155-5 PN ST
HW functional status From FS02 From FS03 From FS01
Firmware version V4.3.0 V4.4 V4.1.0
● FW update possible Yes
Vendor identification (VendorID) 0x002A 002AH 0x002A
Device identifier (DeviceID) 0X0312 0X0312 0X0312
Product function
● I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
● Module swapping during operation (hot swapping) No Yes; In combination with active backplane bus No
● Isochronous mode No Yes Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V15.1 with HSP 187 V16 with HSP 308 V14 or higher with HSP 0223 / integrated with V15 or higher
● STEP 7 configurable/integrated from version V5.5 SP3 / – V5.5 SP3 / – GSDML V2.32
● PROFINET from GSD version/GSD revision V2.3 / – V2.3 / – V2.3 / –
Configuration control
via user data No No No
via dataset No Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V
Reverse polarity protection Yes Yes Yes
Short-circuit protection Yes Yes Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms 5 ms 10 ms
Input current
Current consumption (rated value) 1 A 0.2 A 0.2 A
Current consumption, max. 1.7 A 1.2 A 1.2 A
Inrush current, max. 2.8 A 9 A 9 A
I²t 0.04 A²·s 0.09 A²·s 0.09 A²·s
Power
Infeed power to the backplane bus 14 W 14 W 14 W
Power available from the backplane bus 2.3 W 2.3 W
Power loss
Power loss, typ. 3 W 4.5 W 4.5 W
Address area
Address space per module
● Address space per module, max. 64 byte; per input / output 256 byte; per input / output 256 byte; per input / output
Address space per station
● Address space per station, max. 64 byte; per input / output 512 byte; per input / output 512 byte; per input / output
Hardware configuration
Integrated power supply Yes Yes Yes
System power supply can be plugged in to left of IM No Yes; only with design with U-connectors Yes
Number of permissible power segments 1 3 3
Rack
● Modules per rack, max. 12; I/O modules 30; I/O modules 30; I/O modules
Submodules
● Number of submodules per station, max. 108; 9 submodules / I/O modules 256
Interfaces
Number of PROFINET interfaces 1; 2 ports (switch) RJ45 1 1
1. Interface
Interface types
● RJ 45 (Ethernet) Yes Yes Yes
● Number of ports 2 2 2
● integrated switch Yes Yes Yes
● BusAdapter (PROFINET) No
Protocols
● PROFINET IO Device Yes Yes Yes
● Open IE communication Yes Yes Yes
● Media redundancy Yes Yes Yes; PROFINET MRP
Interface types
RJ 45 (Ethernet)
● Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● 100 Mbps Yes Yes Yes
● Autonegotiation Yes Yes Yes
● Autocrossing Yes Yes Yes
Protocols
PROFINET IO Device
Services
— IRT No Yes Yes
— PROFIenergy No No No
— Prioritized startup No Yes Yes
— Shared device Yes Yes Yes
— Number of IO Controllers with shared device, max. 2 4 2
Redundancy mode
● PROFINET system redundancy (S2) No Yes No
— on S7-1500R/H Yes
— on S7-400H Yes; With GSDML file as of STEP 7 V5.5 SP3
● PROFINET system redundancy (R1) No No
● H-Sync forwarding Yes
Media redundancy
— MRP Yes Yes Yes
— MRPD No Yes No
Open IE communication
● TCP/IP Yes Yes Yes
● SNMP Yes Yes Yes
● LLDP Yes Yes Yes
Isochronous mode
Equidistance No Yes Yes
shortest clock pulse 250 µs 250 µs
max. cycle 4 ms 4 ms
Interrupts/diagnostics/status information
Status indicator Yes Yes Yes
Alarms Yes Yes Yes
Diagnostics function Yes Yes Yes
Diagnostics indication LED
● RUN LED Yes; green LED Yes; green LED Yes; green LED
● ERROR LED Yes; red LED Yes; red LED Yes; red LED
● MAINT LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED
● Connection display LINK TX/RX Yes; 2x green-yellow LEDs Yes; 2x green-yellow LEDs Yes; 2x green-yellow LEDs
Potential separation
between backplane bus and electronics No No No
between PROFINET and all other circuits Yes; 1 500 V AC Yes; 1 500 V AC Yes
between supply and all other circuits No No No
Permissible potential difference
between different circuits Safety extra low voltage SELV
Isolation
Isolation tested with 707 V DC (type test) 707 V DC (type test) 707 V DC (type test)
Standards, approvals, certificates
Network loading class 2
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -30 °C; From FS03 -25 °C; from FS04 -25 °C; From FS03
● horizontal installation, max. 60 °C 60 °C 60 °C
● vertical installation, min. -30 °C; From FS03 -25 °C; from FS04 -25 °C; From FS03
● vertical installation, max. 40 °C 40 °C 40 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
connection method / header
ET-Connection
● via BU/BA Send No No
Dimensions
Width 35 mm 35 mm 35 mm
Height 147 mm 147 mm 147 mm
Depth 129 mm 129 mm 129 mm
Weights
Weight, approx. 236 g 350 g
Weight N/A
Dimensions N/A
Model

6ES7155-5AA00-0AA0, 6ES7155-5AA00-0AC0, 6ES7155-5AA01-0AB0