$ 399.52 – $ 774.62
The IM 155-5 PN interface module enables the connection of ET 200MP to PROFINET and handles the communication between the modules and the higher-level I/O controller autonomously.
Article number | 6ES7155-5AA00-0AA0 | 6ES7155-5AA00-0AC0 | 6ES7155-5AA01-0AB0 | |
ET 200MP, IM 155-5 PN BA | ET 200MP, IM 155-5 PN HF | ET 200MP, IM 155-5 PN ST | ||
General information | ||||
Product type designation | IM 155-5 PN BA | IM 155-5 PN HF | IM 155-5 PN ST | |
HW functional status | From FS02 | From FS03 | From FS01 | |
Firmware version | V4.3.0 | V4.4 | V4.1.0 | |
● FW update possible | Yes | |||
Vendor identification (VendorID) | 0x002A | 002AH | 0x002A | |
Device identifier (DeviceID) | 0X0312 | 0X0312 | 0X0312 | |
Product function | ||||
● I&M data | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | |
● Module swapping during operation (hot swapping) | No | Yes; In combination with active backplane bus | No | |
● Isochronous mode | No | Yes | Yes | |
Engineering with | ||||
● STEP 7 TIA Portal configurable/integrated from version | V15.1 with HSP 187 | V16 with HSP 308 | V14 or higher with HSP 0223 / integrated with V15 or higher | |
● STEP 7 configurable/integrated from version | V5.5 SP3 / – | V5.5 SP3 / – | GSDML V2.32 | |
● PROFINET from GSD version/GSD revision | V2.3 / – | V2.3 / – | V2.3 / – | |
Configuration control | ||||
via user data | No | No | No | |
via dataset | No | Yes | Yes | |
Supply voltage | ||||
Rated value (DC) | 24 V | 24 V | 24 V | |
permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | |
Reverse polarity protection | Yes | Yes | Yes | |
Short-circuit protection | Yes | Yes | Yes | |
Mains buffering | ||||
● Mains/voltage failure stored energy time | 5 ms | 5 ms | 10 ms | |
Input current | ||||
Current consumption (rated value) | 1 A | 0.2 A | 0.2 A | |
Current consumption, max. | 1.7 A | 1.2 A | 1.2 A | |
Inrush current, max. | 2.8 A | 9 A | 9 A | |
I²t | 0.04 A²·s | 0.09 A²·s | 0.09 A²·s | |
Power | ||||
Infeed power to the backplane bus | 14 W | 14 W | 14 W | |
Power available from the backplane bus | 2.3 W | 2.3 W | ||
Power loss | ||||
Power loss, typ. | 3 W | 4.5 W | 4.5 W | |
Address area | ||||
Address space per module | ||||
● Address space per module, max. | 64 byte; per input / output | 256 byte; per input / output | 256 byte; per input / output | |
Address space per station | ||||
● Address space per station, max. | 64 byte; per input / output | 512 byte; per input / output | 512 byte; per input / output | |
Hardware configuration | ||||
Integrated power supply | Yes | Yes | Yes | |
System power supply can be plugged in to left of IM | No | Yes; only with design with U-connectors | Yes | |
Number of permissible power segments | 1 | 3 | 3 | |
Rack | ||||
● Modules per rack, max. | 12; I/O modules | 30; I/O modules | 30; I/O modules | |
Submodules | ||||
● Number of submodules per station, max. | 108; 9 submodules / I/O modules | 256 | ||
Interfaces | ||||
Number of PROFINET interfaces | 1; 2 ports (switch) RJ45 | 1 | 1 | |
1. Interface | ||||
Interface types | ||||
● RJ 45 (Ethernet) | Yes | Yes | Yes | |
● Number of ports | 2 | 2 | 2 | |
● integrated switch | Yes | Yes | Yes | |
● BusAdapter (PROFINET) | No | |||
Protocols | ||||
● PROFINET IO Device | Yes | Yes | Yes | |
● Open IE communication | Yes | Yes | Yes | |
● Media redundancy | Yes | Yes | Yes; PROFINET MRP | |
Interface types | ||||
RJ 45 (Ethernet) | ||||
● Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
● 100 Mbps | Yes | Yes | Yes | |
● Autonegotiation | Yes | Yes | Yes | |
● Autocrossing | Yes | Yes | Yes | |
Protocols | ||||
PROFINET IO Device | ||||
Services | ||||
— IRT | No | Yes | Yes | |
— PROFIenergy | No | No | No | |
— Prioritized startup | No | Yes | Yes | |
— Shared device | Yes | Yes | Yes | |
— Number of IO Controllers with shared device, max. | 2 | 4 | 2 | |
Redundancy mode | ||||
● PROFINET system redundancy (S2) | No | Yes | No | |
— on S7-1500R/H | Yes | |||
— on S7-400H | Yes; With GSDML file as of STEP 7 V5.5 SP3 | |||
● PROFINET system redundancy (R1) | No | No | ||
● H-Sync forwarding | Yes | |||
Media redundancy | ||||
— MRP | Yes | Yes | Yes | |
— MRPD | No | Yes | No | |
Open IE communication | ||||
● TCP/IP | Yes | Yes | Yes | |
● SNMP | Yes | Yes | Yes | |
● LLDP | Yes | Yes | Yes | |
Isochronous mode | ||||
Equidistance | No | Yes | Yes | |
shortest clock pulse | 250 µs | 250 µs | ||
max. cycle | 4 ms | 4 ms | ||
Interrupts/diagnostics/status information | ||||
Status indicator | Yes | Yes | Yes | |
Alarms | Yes | Yes | Yes | |
Diagnostics function | Yes | Yes | Yes | |
Diagnostics indication LED | ||||
● RUN LED | Yes; green LED | Yes; green LED | Yes; green LED | |
● ERROR LED | Yes; red LED | Yes; red LED | Yes; red LED | |
● MAINT LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED | |
● Connection display LINK TX/RX | Yes; 2x green-yellow LEDs | Yes; 2x green-yellow LEDs | Yes; 2x green-yellow LEDs | |
Potential separation | ||||
between backplane bus and electronics | No | No | No | |
between PROFINET and all other circuits | Yes; 1 500 V AC | Yes; 1 500 V AC | Yes | |
between supply and all other circuits | No | No | No | |
Permissible potential difference | ||||
between different circuits | Safety extra low voltage SELV | |||
Isolation | ||||
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | |
Standards, approvals, certificates | ||||
Network loading class | 2 | |||
Ambient conditions | ||||
Ambient temperature during operation | ||||
● horizontal installation, min. | -30 °C; From FS03 | -25 °C; from FS04 | -25 °C; From FS03 | |
● horizontal installation, max. | 60 °C | 60 °C | 60 °C | |
● vertical installation, min. | -30 °C; From FS03 | -25 °C; from FS04 | -25 °C; From FS03 | |
● vertical installation, max. | 40 °C | 40 °C | 40 °C | |
Altitude during operation relating to sea level | ||||
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | |
connection method / header | ||||
ET-Connection | ||||
● via BU/BA Send | No | No | ||
Dimensions | ||||
Width | 35 mm | 35 mm | 35 mm | |
Height | 147 mm | 147 mm | 147 mm | |
Depth | 129 mm | 129 mm | 129 mm | |
Weights | ||||
Weight, approx. | 236 g | 350 g |
Weight | N/A |
---|---|
Dimensions | N/A |