$ 404.52
The IM 155-5 DP ST interface module enables the connection of ET 200MP to PROFIBUS and handles the communication between the modules and the higher-level PROFIBUS master autonomously in the PLC.
| Article number | 6ES7155-5BA00-0AB0 | |
| ET 200MP, IM155-5 DP ST | ||
| General information | ||
| Product type designation | IM 155-5 DP ST | |
| HW functional status | From FS01 | |
| Firmware version | V2.0.0 | |
| Vendor identification (VendorID) | 81AAh | |
| Product function | ||
| ● I&M data | Yes; I&M0 to I&M3 | |
| ● Module swapping during operation (hot swapping) | No | |
| ● Isochronous mode | No | |
| Engineering with | ||
| ● STEP 7 TIA Portal configurable/integrated from version | V13 / V13 | |
| ● STEP 7 configurable/integrated from version | V5.5 SP3 / – | |
| ● PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 | |
| Configuration control | ||
| via user data | No | |
| via dataset | No | |
| Supply voltage | ||
| Rated value (DC) | 24 V | |
| permissible range, lower limit (DC) | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes | |
| Short-circuit protection | Yes | |
| Mains buffering | ||
| ● Mains/voltage failure stored energy time | 5 ms | |
| Input current | ||
| Current consumption (rated value) | 0.2 A; at 24 V DC and without load | |
| Current consumption, max. | 1.2 A; at 20.4 V DC and max. load | |
| Inrush current, max. | 4 A | |
| I²t | 0.09 A²·s | |
| from interface 5 V DC, max. | 80 mA | |
| Power | ||
| Infeed power to the backplane bus | 14 W | |
| Power loss | ||
| Power loss, typ. | 4 W | |
| Address area | ||
| Address space per module | ||
| ● Address space per module, max. | 32 byte; per input / output | |
| Address space per station | ||
| ● Address space per station, max. | 244 byte; per input / output | |
| Hardware configuration | ||
| Integrated power supply | Yes | |
| System power supply can be plugged in to left of IM | No | |
| Number of permissible power segments | 1 | |
| Rack | ||
| ● Modules per rack, max. | 12; I/O modules | |
| Interfaces | ||
| Number of PROFIBUS interfaces | 1 | |
| 1. Interface | ||
| Interface types | ||
| ● RS 485 | Yes | |
| Protocols | ||
| ● PROFIBUS DP slave | Yes | |
| Interface types | ||
| RS 485 | ||
| ● Transmission rate, max. | 12 Mbit/s | |
| Protocols | ||
| Open IE communication | ||
| ● TCP/IP | No | |
| PROFIBUS DP | ||
| Services | ||
| — SYNC capability | Yes | |
| — FREEZE capability | Yes | |
| — DPV1 | Yes | |
| Interrupts/diagnostics/status information | ||
| Status indicator | Yes | |
| Alarms | Yes | |
| Diagnostics function | Yes | |
| Diagnostics indication LED | ||
| ● RUN LED | Yes; green LED | |
| ● ERROR LED | Yes; red LED | |
| ● MAINT LED | Yes; Yellow LED | |
| ● Connection display DP | Yes; green LED | |
| Potential separation | ||
| between backplane bus and electronics | No | |
| between PROFIBUS DP and all other circuit components | Yes | |
| between supply and all other circuits | No | |
| Isolation | ||
| Isolation tested with | 707 V DC (type test) | |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● horizontal installation, min. | -25 °C; from FS04 | |
| ● horizontal installation, max. | 60 °C | |
| ● vertical installation, min. | -25 °C; from FS04 | |
| ● vertical installation, max. | 40 °C | |
| Altitude during operation relating to sea level | ||
| ● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | |
| connection method / header | ||
| ET-Connection | ||
| ● via BU/BA Send | No | |
| Dimensions | ||
| Width | 35 mm | |
| Height | 147 mm | |
| Depth | 129 mm | |
| Weights | ||
| Weight, approx. | 360 g | |