The IM 153-1/153-2 interface module serves as the head module (IM; Interface Module) of the ET 200M. Up to 8 or 12 I/O modules from the module product range of the S7-300 automation system can be connected to the interface module.
The interface module and the necessary I/O modules are assembled on a DIN rail for the S7-300. During assembly, the I/O modules are connected to one another using bus connectors and using the IM 153 interface modules.
Article number | 6ES7153-1AA03-0XB0 |
ET200M, Interface Module IM153-1 | |
General information | |
Product type designation | IM 153-1 DP ST |
Firmware version | |
Vendor identification (VendorID) | 801Dh |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
external protection for power supply lines (recommendation) | not necessary |
Mains buffering | |
● Mains/voltage failure stored energy time | 5 ms |
Input current | |
Current consumption, max. | 350 mA; At 24 V DC |
Inrush current, typ. | 2.5 A |
I²t | 0.1 A²·s |
output voltage / header | |
Rated value (DC) | 5 V |
Output current | |
for backplane bus (5 V DC), max. | 1 A |
Power loss | |
Power loss, typ. | 3 W |
Address area | |
Addressing volume | |
● Inputs | 128 byte |
● Outputs | 128 byte |
Hardware configuration | |
Number of modules per DP slave interface, max. | 8 |
Time stamping | |
Accuracy | |
Number of message buffers | |
Messages per message buffer | |
Number of stampable digital inputs, max. | |
Time format | |
Time resolution | |
Time interval for transmitting the message buffer if a message is present | |
Time stamp on signal change | |
Interfaces | |
Transmission procedure | RS 485 |
Transmission rate, max. | 12 Mbit/s |
1. Interface | |
automatic detection of transmission rate | Yes |
Interface types | |
● Output current of the interface, max. | 90 mA |
● Design of the connection | 9-pin sub D socket |
PROFIBUS DP slave | |
● GSD file | (for DPV1) SIEM801D.GSD; SI01801D.GSG |
● automatic baud rate search | Yes |
Protocols | |
Bus protocol/transmission protocol | PROFIBUS DP to EN 50170 |
Protocols (Ethernet) | |
● TCP/IP | No |
PROFIBUS DP | |
● Number of node addresses, max. | 1 to 125 permitted |
Services | |
— SYNC capability | Yes |
— FREEZE capability | Yes |
— Direct data exchange (slave-to-slave communication) | Yes; Sender |
Potential separation | |
Potential separation exists | Yes |
Isolation | |
Isolation tested with | Isolation voltage 500 V |
Degree and class of protection | |
IP degree of protection | IP20 |
Ambient conditions | |
Ambient temperature during operation | |
● min. | 0 °C |
● max. | 60 °C |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 40 °C |
Altitude during operation relating to sea level | |
● Installation altitude above sea level, max. | 3 000 m |
configuration / header | |
Configuration software | |
● STEP 7 | STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file |
Dimensions | |
Width | 40 mm |
Height | 125 mm |
Depth | 117 mm |
Weights | |
Weight, approx. | 360 g |
Weight | 0.268 kg |
---|---|
Dimensions | 13.1 × 15.2 × 5.2 cm |