The CM IO-Link communication module enables data exchange with up to 4 IO-Link devices.
IO-Link devices (e.g. sensors) with a Class A port are connected using a 3-wire cable. IO-Link devices that require additional supply voltage and have a Class B port (e.g. actuators) are connected using a 5-wire cable.
Thanks to the compatibility of IO-Link with standard sensors, commercially available sensors in accordance with IEC 61131 Type 1 can also be operated on the IO-Link master.
The 30 mm wide I/O modules are especially suitable for use in extremely confined spaces, have settable parameters and diagnostic functions and can thus be adapted flexibly to the respective process requirements.
Article number | 6ES7147-5JD00-0BA0 |
ET 200AL, cm 4x IO-Link, 4xM12 | |
General information | |
Product type designation | CM 4x IO-Link |
HW functional status | FS05 |
Firmware version | V1.2.x |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | STEP 7 V13 SP1 or higher |
● STEP 7 configurable/integrated from version | From V5.5 SP4 Hotfix 3 |
● PROFIBUS from GSD version/GSD revision | GSD as of Revision 5 |
● PROFINET from GSD version/GSD revision | GSDML V2.3.1 |
Supply voltage | |
power supply according to NEC Class 2 required | No |
Load voltage 1L+ | |
● Rated value (DC) | 24 V |
● permissible range, lower limit (DC) | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V |
● Reverse polarity protection | Yes |
Load voltage 2L+ | |
● Rated value (DC) | 24 V |
● permissible range, lower limit (DC) | 20.4 V |
● permissible range, upper limit (DC) | 28.8 V |
● Reverse polarity protection | Yes; against destruction; load increasing |
Input current | |
Current consumption (rated value) | 40 mA; without load |
from load voltage 1L+ (unswitched voltage) | 4 A; Maximum value |
from load voltage 2L+, max. | 4 A; Maximum value |
Encoder supply | |
Number of outputs | 4 |
24 V encoder supply | |
● Short-circuit protection | Yes; per module, electronic |
● Output current, max. | 1.4 A; Total current of all ports |
Power loss | |
Power loss, typ. | 2.6 W |
IO-Link | |
Number of ports | 4 |
● of which simultaneously controllable | 4 |
IO-Link protocol 1.0 | Yes |
IO-Link protocol 1.1 | Yes |
Transmission rate | 4.8 kBaud (COM1); 38.4 kBaud (COM2), 230 kBaud (COM3) |
Size of process data, input per port | 32 byte |
Size of process data, input per module | 132 byte |
Size of process data, output per port | 32 byte |
Size of process data, output per module | 128 byte |
Memory size for device parameter | 2 kbyte; for each port |
Master backup | Possible with function block IO_LINK_MASTER |
Configuration without S7-PCT | Possible; autostart/manual function |
Cable length unshielded, max. | 20 m |
Operating modes | |
● IO-Link | Yes |
● DI | Yes |
● DQ | Yes; max. 100 mA |
Connection of IO-Link devices | |
● Port type A | Yes; via 3-core cable |
● Port type B | Yes; Additional device supply: 1.6 A total current of all ports |
Interrupts/diagnostics/status information | |
Alarms | |
● Diagnostic alarm | Yes; Parameterizable |
Diagnoses | |
● Monitoring the supply voltage | Yes |
● Wire-break | Yes |
● Short-circuit | Yes |
Diagnostics indication LED | |
● Channel status display | Yes; green LED |
● for module diagnostics | Yes; green/red LED |
● For load voltage monitoring | Yes; green LED |
Potential separation | |
between the load voltages | Yes |
Potential separation channels | |
● between the channels | No |
● between the channels and backplane bus | Yes |
● between the channels and the power supply of the electronics | No |
Isolation | |
Isolation tested with | 707 V DC (type test) |
Degree and class of protection | |
IP degree of protection | IP65/67 |
Standards, approvals, certificates | |
Suitable for safety-related tripping of standard modules | Yes; From FS01 |
Highest safety class achievable for safety-related tripping of standard modules | |
● Performance level according to ISO 13849-1 | PL d |
● Category according to ISO 13849-1 | Cat. 3 |
● SILCL according to IEC 62061 | SILCL 2 |
Ambient conditions | |
Ambient temperature during operation | |
● min. | -30 °C |
● max. | 55 °C |
connection method / header | |
Design of electrical connection for the inputs and outputs | M12, 5-pole |
Design of electrical connection for supply voltage | M8, 4-pole |
ET-Connection | |
● ET-Connection | M8, 4-pin, shielded |
Dimensions | |
Width | 30 mm |
Height | 159 mm |
Depth | 40 mm |
Weights | |
Weight, approx. | 145 g |
Weight | 0.169 kg |
---|---|
Dimensions | 4.5 × 17.6 × 4 cm |