SFAH-1U-Q4S-PNLK-PNVBA-M8 – Festo Flow Sensors
$ 234.96
Manufacturer Part Number: Festo 8058466
Festo Flow Sensors: SFAH-1U-Q4S-PNLK-PNVBA-M8
OEM Spec Ref
The Festo SFAH-1U-Q4S-PNLK-PNVBA-M8, with the MPN 8058466, is a state-of-the-art flow sensor designed for precise and efficient monitoring of fluid dynamics within industrial systems. Engineered by Festo, a global leader in automation technology, this sensor embodies innovation and reliability, ensuring optimal performance in a variety of applications. With its advanced features and robust design, the SFAH-1U-Q4S-PNLK-PNVBA-M8 is a pivotal component for enhancing system monitoring and operational efficiency across multiple industries.
Key Features:
- Accurate Flow Measurement: This sensor provides exact flow rate detection, facilitating the meticulous monitoring and control of fluid dynamics, critical for maintaining system efficiency and performance.
- High Compatibility: Designed with a universal M8 connector, it ensures seamless integration with a wide range of industrial equipment, making it highly adaptable to various operational setups.
- Durability in Industrial Environments: The sensor’s construction is tailored for longevity and reliability, capable of withstanding the harsh conditions typically found in industrial settings.
- Easy Installation and Maintenance: Its design prioritizes user-friendliness, featuring plug-and-play installation and minimal maintenance requirements, significantly reducing downtime.
- Versatile Application: Whether it’s in water treatment, chemical processing, or HVAC systems, the SFAH-1U-Q4S-PNLK-PNVBA-M8 adapts effortlessly, providing critical data for system optimization.
Benefits:
- Enhanced System Efficiency: By offering precise flow monitoring, it aids in the optimization of fluid dynamics, leading to improved system performance and energy efficiency.
- Reduced Operational Costs: The sensor’s accuracy and reliability contribute to decreased waste and lower maintenance expenses, offering a cost-effective solution for businesses.
- Increased System Reliability: With its durable build and precise monitoring capabilities, the sensor ensures consistent operation and longevity of industrial systems.
- Simplified System Integration: Its compatibility and ease of installation make it a straightforward addition to existing systems, ensuring a hassle-free upgrade path.
Applications:
- Process Automation: Ideal for automating fluid monitoring in manufacturing processes, ensuring consistent quality and operational efficiency.
- Water Management Systems: Crucial for monitoring and managing water flow in treatment facilities, irrigation systems, and distribution networks, optimizing resource use.
- Industrial Cooling Systems: Enhances the performance and efficiency of cooling systems by providing accurate flow data, essential for maintaining optimal operating conditions.
- Pharmaceutical Production: Ensures precise control of fluid flow in pharmaceutical manufacturing, critical for product quality and compliance.
The Festo SFAH-1U-Q4S-PNLK-PNVBA-M8 flow sensor represents a leap forward in fluid monitoring technology. Its precision, adaptability, and robustness make it an indispensable tool for industries looking to enhance their operations through accurate flow measurement. Its integration promises not only operational excellence but also substantial cost savings and improved system reliability, marking it as a key asset for any sector reliant on fluid management.
Technical Data
Feature | Specification |
---|---|
Symbol | 00995794 |
Certification | RCM compliance mark c UL us – Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive As per EU RoHS directive |
UKCA marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions |
Certificate issuing authority | UL E322346 |
Note on materials | RoHS-compliant |
Measured variable | Mass flow rate Volumetric flow rate |
Flow direction | Unidirectional |
Measuring principle | Thermal |
Method of measurement | Heat transfer |
Flow measuring range start value | 0.02 l/min |
Flow measuring range end value | 1 l/min |
Operating pressure | -0.9 bar … 10 bar |
Operating medium | Argon Compressed air as per ISO 8573-1:2010 [6:4:4] Nitrogen |
Temperature of medium | 0 °C to 50 °C |
Ambient temperature | 0 °C to 50 °C |
Nominal temperature | 23 °C |
Accuracy of flow rate | ± (2% o.m.v. + 1% FS) |
Zero point repetition accuracy | 0.2 %FS |
Repetition accuracy margin | 0.8 %FS |
Temperature co-efficient margin | typ. 0.15% FS/K |
Pressure influence margin | 1 %FS/b. |
Switching output | 2 x PNP or 2 x NPN switchable |
Switching function | Window comparator Threshold value comparator Auto difference monitoring |
Switching element function | N/C contact/N/O contact switchable |
Max. output current | 100 mA |
Analog output | 0 – 10 V 4 – 20 mA 1 – 5 V |
Flow characteristic curve, start value | 0 l/min |
Flow characteristic curve, end value | 1 l/min |
Max. load resistance of current output | 500 Ohm |
Min. load resistance of voltage output | 20 kOhm |
Short-circuit protection | yes |
Overload protection | Available |
Protocol | IO-Link® |
IO-Link®, protocol version | Device V 1.1 |
IO-Link®, profile | Smart sensor profile |
IO-Link®, function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel |
IO-Link®, communication mode | COM2 (38,4 kBd) |
IO-Link®, SIO mode support | Yes |
IO-Link®, port class | A |
IO-Link®, process data width IN | 3 Byte |
IO-Link®, process data content IN | 1 bit BDC (volume monitoring) 14 bit PDV (flow measurement) 2 bit BDC (flow monitoring) |
IO-Link®, service data contents IN | 32 bit volume/mass measurement |
IO-Link®, minimum cycle time | 4 ms |
IO-Link®, data memory required | <500 byte |
DC operating voltage range | 22 V to 26 V |
Idle current | ≤25 mA |
Reverse polarity protection | For all electrical connections |
Electrical connection 1, connection type | Plug |
Electrical connection 1, connection technology | M8x1 A-coded as per EN 61076-2-104 |
Electrical connection 1, number of pins/wires | 4 |
Electrical connection for input 1, connection pattern | 00991171 |
Type of mounting | With accessories |
Mounting position | Any |
Pneumatic connection | For pneumatic tubing outside diameter 4 mm |
Pneumatic connection, outlet direction | Straight |
Product weight | 60 g |
Housing material | PA-reinforced |
Materials in contact with the media | Wrought aluminum alloy, anodized Epoxy NBR PA-reinforced Silicon Silicon nitride High-alloy stainless steel |
Display type | Illuminated LCD, multi-color |
Displayable unit(s) | g g/min l l/h l/min scft scft/h |
Setting options | IO-Link® Teach-in Via display and pushbuttons |
Protection against tampering | IO-Link® PIN code |
Degree of protection | IP40 |
Pressure drop | <5 mbar |
Protection class | III |
Corrosion resistance class (CRC) | 2 – Moderate corrosion stress |
LABS (PWIS) conformity | VDMA24364-B2-L |