SFAB-600U-WQ12-2SA-M12 – Festo Flow Sensors
$ 1,110.56
Manufacturer Part Number: Festo 563795
Festo Flow Sensors: SFAB-200U-WQ8-2SA-M12
OEM Spec Ref
The Festo SFAB-200U-WQ8-2SA-M12, with its MPN 563795, is a state-of-the-art flow sensor that sets a new standard in monitoring and controlling fluid dynamics within various industrial applications. This Festo flow sensor stands at the forefront of precision engineering, designed to deliver unparalleled accuracy, efficiency, and reliability in the most demanding environments.
Key Features:
- Exceptional Accuracy and Sensitivity: Designed to detect even minute changes in flow rates, ensuring optimal control and monitoring of fluid dynamics.
- Robust Construction: Built to withstand harsh industrial conditions, ensuring long-term reliability and performance.
- Compact and Versatile Design: Its sleek form factor allows for flexible installation options, making it suitable for a wide range of applications.
- Easy Integration: Equipped with M12 connectors, it ensures seamless integration into existing systems, enhancing operational efficiency without the need for extensive modifications.
Benefits:
- Enhanced Operational Efficiency: By providing precise flow measurements, it helps optimize processes, reduce waste, and improve output quality.
- Reduced Downtime and Maintenance: Durable construction and reliable performance translate to fewer interruptions and lower maintenance costs.
- Energy Savings: Efficient monitoring and control contribute to reduced energy consumption, aligning with sustainability goals.
Applications:
- Process Control: Essential for industries requiring precise fluid management, such as chemical, pharmaceutical, and food processing.
- Water Treatment: Optimizes water flow and treatment processes, ensuring efficiency and environmental compliance.
- Automotive Manufacturing: Enhances precision in coolant systems, painting, and coating applications, contributing to superior product quality.
The Festo SFAB-200U-WQ8-2SA-M12 redefines flow monitoring, offering a blend of precision, durability, and efficiency that elevates operational standards across multiple industries. Its integration promises not only to streamline processes but also to achieve significant cost savings and sustainability objectives, marking it as an indispensable tool for modern industrial applications.
Technical Data
Feature | Specification |
---|---|
Symbol | 00992242 00992243 00995566 |
Certification | RCM compliance mark c UL us – Recognized (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive as per EU explosion protection directive (ATEX) As per EU RoHS directive |
UKCA marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions |
Explosion prevention and protection | Zone 2 (ATEX) Zone 22 (ATEX) |
ATEX category gas | II 3G |
Type of ignition protection for gas | Ex nA IIC T5 X Gc |
ATEX category for dust | II 3D |
Type of (ignition) protection for dust | Ex tc IIIB T80°C X Dc IP54 |
Explosive ambient temperature | 0°C <= Ta <= +50°C |
Certificate issuing authority | UL E322346 |
Note on materials | RoHS-compliant |
Measured variable | Mass flow rate Temperature Volume Volumetric flow rate |
Flow direction | Unidirectional P1 -> P2 |
Measuring principle | Thermal |
Method of measurement | Heat loss |
Flow measuring range start value | 0.1 l/min … 10 l/min |
Flow measuring range end value | 3 l/min … 1000 l/min |
Temperature measuring range start value | 0 °C |
Temperature measuring range end value | 50 °C |
Operating pressure | 0 MPa … 1 MPa |
Operating pressure | 0 bar … 10 bar |
Operating medium | Argon Compressed air as per ISO 8573-1:2010 [6:4:4] Compressed air as per ISO 8573-1:2010 [7:4:4] Carbon dioxide Nitrogen |
Temperature of medium | 0 °C … 50 °C |
Ambient temperature | 0 °C … 50 °C |
Nominal temperature | 23 °C |
Accuracy of flow rate | ± (3% o.m.v. + 0.3% FS) |
Accuracy of temperature in ± °C | 5 °C |
Zero point repetition accuracy in ± %FS | 0.2 %FS |
Repetition accuracy margin in ± %FS | 0.8 %FS |
Temperature co-efficient margin in ± %FS/K | typ. 0. 1%FS/K |
Pressure influence of margin in ±%FS/bar | 0.5 %FS/b. |
Switching output | 2 x PNP or 2 x NPN switchable |
Switching function | Window comparator Threshold value comparator |
Switching element function | N/C contact/N/O contact switchable |
On time | 10 ms |
Switch-off time | 10 ms |
Max. output current | 100 mA |
Analog output | 0 – 10 V 4 – 20 mA 1 – 5 V |
Flow characteristic curve, start value | 0 l/min … |
Flow characteristic curve, end value | 10 l/min … 1000 l/min |
Temperature characteristic curve start value | 0 °C |
Temperature characteristic curve end value | 100 °C |
Output characteristic curve initial value | 0 V |
End value output characteristic curve | 10 V |
Output characteristic curve initial value | 4 mA |
End value output characteristic curve | 20 mA |
Max. load resistance of current output | 500 Ohm |
Min. load resistance of voltage output | 10 kOhm |
Short-circuit protection | Yes |
Overload protection | Available |
Protocol | IO-Link® |
IO-Link, revision ID | V1.1 |
IO-Link, device profile | Function Extended identification Function Measurement data, standard resolution Function Multiple switching signal Firmware update Function Locator Function Product URI Function Teach single value Identification and diagnosis Smart Sensor – SSP 4.1.2 |
IO-Link, transmission rate | COM3 |
IO-Link®, SIO mode support | Yes |
IO-Link, port type | Class A |
IO-Link, process data length (output) | 0 bit |
IO-Link, process data length (input) | 64 bit |
IO-Link®, process data content IN | Flow rate measured value 16-bit MDC Flow rate monitoring 2-bit SSC Temperature measured value 16-bit MDC Temperature monitoring 2-bit SSC Volume / mass pulse 1 bit SSC |
IO-Link®, service data contents IN | Volume / mass measured value 32-bit |
IO-Link®, minimum cycle time | 1.2 ms |
IO-Link®, data memory required | 500 byte |
DC operating voltage range | 15 V … 30 V |
Idle current | 90 mA … 120 mA |