Product name | Safety control unit | |
---|---|---|
Model No. | SF-C21 | |
Applicable standards |
Safety | IEC 61508-1 to 3, EN 61508-1 to 3(SIL3), ISO 13849-1:2015 (Category 4, PLe), IEC 61131-2, IEC 61010-2-201, IEC 62061(SILCL3), UL 61010-1, UL 61010-2-201, UL 1998, KS C 9811 : 2019(EN 55011), KS C 9610-6-2 : 2019(EN 61000-6-2) |
EMC | IEC 61000-6-2, IEC 61326-3-1, EN 55011 | |
Related standards | IEC 60947-1, IEC 60947-5-1, IEC 60947-5-2, IEC 60947-5-5 IEC 60947-5-8, IEC 61496-1, IEC TS 62046, ISO 13851 |
|
Applicable regulations and certifications | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations), TÜV SÜD certification, TÜV SÜD certification (USA, Canada), Korea’s Radio Waves Act conformity registration | |
Supply voltage (Note 1, 2) |
Power supply for internal |
24 V DC +10-15% Ripple P-P10 % or less |
Power supply for external |
24 V DC +10-15% Ripple P-P10 % or less | |
Current consumption (Note 1, 2) |
Power supply for internal |
200 mA or less |
Power supply for external |
100 mA or less | |
Safety input (IN1 to IN8) | 2×4 inputs, Rated voltage: Same as the voltage of the power supply for internal | |
ON level / OFF level |
Input voltage: 18 V, Input current: 3.5 mA / Input voltage: 5 V, Input current: 1.0 mA | |
Rated input current / Input impedance |
5 mA approx. / 4.7 K Ω approx. | |
Duration of detectable ON state |
10 ms or more | |
Duration of undetectable OFF state |
0.7 ms or less | |
Control output (OUT1 to OUT4) |
PNP open-collector transistor with 2 outputs × 2 • Maximum source current: 300 mA / output • Applied voltage: Same as the voltage of the power supply for external • Residual voltage: 2.5 V or less • Leakage current: 100 μA or less (Including power supply OFF condition) |
|
Output mode | True : ON, False : OFF | |
ON delay function / OFF delay function |
Incorporated / Incorporated | |
Short-circuit protection / Response time |
Incorporated / OFF response: 10 ms or less, ON response: 100 ms or less | |
Auxiliary output (AUX1 to AUX4) (Non-safety output) |
PNP open-collector transistor with 1 output × 4 • Maximum source current: 60 mA / output • Applied voltage: Same as the voltage of the power supply for external • Residual voltage: 2.5 V or less • Leakage current: 100 μA or less (Including power supply OFF condition) |
|
Output mode (Factory defaults) |
AUX1: Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF) AUX2: Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF) AUX3: Reset trigger output (ON under reset release wait condition) AUX4: Lockout output (OFF when lockout) |
|
Output mode (Any of the auxiliary outputs can be customized using the software tool) |
Negative logic of OUT1 / OUT2(ON when OUT1 / OUT2 is OFF) Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF) Positive logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is ON) Positive logic of OUT3 / OUT4(ON when OUT3 / OUT4 is ON) Outputs A, B, C, and D of diagnosis results of input blocks (ON when logic is true) Outputs E, F, and G of internal logic circuit diagnostic results (ON when logic is true) Reset trigger output (ON under reset release wait condition) Lockout output (OFF when lockout) Muting indicator output (ON when muting / override) Monitor output in response to IN1 to IN8 (ON when input) No output (normally OFF) |
|
Short-circuit protection / Response time |
Incorporated / 10 ms or less | |
Muting indicator output | Semiconductor photo MOS relay output × 1 • Maximum load current: 60 mA • Supply voltage: Same as the voltage of the power supply for internal • Residual voltage: 2.5 V or less • Leakage current: 100 μA or less (Including power supply OFF condition) |
|
Output mode | ON when muting / override | |
Short-circuit protection / Response time |
Incorporated / 10 ms or less | |
Interlock function / Lockout release function |
Incorporated / Incorporated | |
External device monitor function |
Incorporated | |
Communication function (MODBUS RTU) |
Interface: RS-485 Protocol: MODBUS RTU Maximum transmission distance: 100 m 328.084 ft Maximum number of units that can be connected: 8 units (slaves) |
|
Logic selection function | No.0: Customization control No.1: Overall stop control No.2: Parallel muting control No.3: Sequential muting control No.4: Partial stop control 1 No.5: Partial stop control 2 No.6: Two-hand control No.7: OR control No.8: Operation mode selection control |
|
Logic setting function | Input mode, control mode, output mode, reset mode, auxiliary output mode | |
Pollution degree / Excess voltage category |
2 / II | |
Usable altitude (Note 3) | 2,000 m 6561.680 ft or less | |
Startup time after power on |
2 sec. or less | |
PFHD(Note 4) / MTTFD (Note 4) | 9.73 × 10−10 / 100 years or more | |
Protection | IP20 (IEC) (must be installed in a control panel with protection IP54 or higher) | |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉ |
|
Ambient humidity | 30 to 85% RH, Storage: 30 to 85% RH | |
Dielectric strength voltage / Insulation resistance |
1,000 V AC for one min. / 20 MΩ, or more, with 500 V DC megger. (All inputs connected together – USB port, all inputs connected together – RS-485 port, USB port – RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together – all input connected together, all outputs connected together – USB port, all outputs connected together – RS-485 port) |
|
Vibration resistance | 5 to 8.4 Hz frequency, 3.5 mm 0.138 in half amplitude, 8.4 to 150 Hz frequency, Max. acceleration 9.8 m/s2 (1 G), in X, Y and Z directions for two hours each (IEC / EN 60068-2-6) |
|
Shock resistance | 147 m/s2 (15 G) 11 ms in X, Y and Z directions three times each (IEC / EN 60068-2-27) | |
Connection method | Input / output and power supply: Detachable spring cage terminal blocks, RS-485: Detachable spring-cage terminal block, USB: Mini-B male |
|
Maximum cable length | 100 m 328.084 ft or less | |
Material | Main unit enclosure: Polycarbonate / ABS polymer alloy, Enclosure: Polycarbonate |
|
Weight | Net weight: 190 g approx., Gross weight: 320 g approx. |
Notes:
1) “Power supply for internal” is the power supply for safety input. “Power supply for external” is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.
2) The power supply unit connected to this device must satisfy the conditions below.
• Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10% or less.)
• Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)
• Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less
• Power supply unit with an output holding time of 20 ms or more.
• Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)
• Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
3) Do not use or store this device in a pressurized environment beyond the atmospheric pressure at sea level.
4) PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)
With built-in RS-485, SF-C21 can read out its status, error history, etc. to an external device such as a general-purpose PLC, using the MODBUS RTU protocol.
Up to eight SF-C21 units can communicate with the external device as the master station.
The communication preference of MODBUS RTU is set with the DIP switch on the main unit or the software tool “Configurator SF-C”.
Types of data that can be read out
• Status (HIGH, LOW) of safety input and reset / EDM output
• Status (HIGH, LOW) of control output, auxiliary output, and muting indicator output
• Lockout history
• Logic No. change history
■ MODBUS RTU SPECIFICATIONS
Interface | RS-485 |
---|---|
Max. transmission distance | 100m 328.084 ft |
Communication address | 1-247 |
Data length | 8 bits(fixed) |
Parity bit | Without / Odd / Even |
Stop bit | 1 bit / 2 bits |
Communication speed | 9,600 bps 19,200 bps 38,400 bps 57,600 bps 115,200 bps |
■ MAIN BODY DIP SWITCH SPECIFICATIONS
Switch NO. |
Setting item | Input status | |
---|---|---|---|
OFF | ON | ||
1 | Communication preference settings |
DIP switches take precedence | Software tools take precedence |
2 | Parity bit presence | With | Without |
3 | Parity bit type | Odd | Even |
4 | Stop bit | 1 | 2 |
5 | Communication address 1 | SW5:OFF, SW6:OFF | |
Communication address 2 | SW5:ON, SW6:OFF | ||
6 | Communication address 3 | SW5:OFF, SW6:ON | |
Communication address 4 | SW5:ON, SW6:ON | ||
7 | Communication speed | 9,600 bps | 19,200 bps |
8 | Reserved | – | – |
9 | Reserved | – | – |
10 | Reserved | – | – |
Note: The SF-C21 cannot be controlled by an external device.
Weight | 0.320 kg |
---|