$ 831.60 – $ 4,779.94
The new 3VA circuit breakers set new standards in terms of flexibility and variety of modular accessories. Standardized accessories suitable for use with several sizes of circuit breaker from all the 3VA ranges help to cut costs and save installation time.
Article Number | 3VA1112-5GF46-0AA0 |
Product Brand Name | SENTRON |
Product Designation | Molded case circuit breaker |
Product Version | Line protection |
Design of the Over-current Release | TM240 |
Protection Function of the Over-current Release | LI |
Number of Poles | 4 |
General Technical Data | |
Insulation Voltage / Rated Value | 800 V |
Max. Rated Operational Voltage Ue with DC | 600 V |
Operating Voltage / at AC / Rated Value | 690 V |
Power Loss [W] / Maximum | 28.1 W |
Mechanical Service Life (Switching Cycles) / Typical | 20 000 |
Electrical Endurance (Switching Cycles) / at AC-1 / at 380/415 V 50/60 Hz | 9 000 |
Electrical Endurance (Switching Cycles) / at AC-1 / at 690 V 50/60 Hz | 6 300 |
Neutral Conductors / Upgradeable/Retrofittable | No |
Ground-Fault Monitoring Version | Without |
Product Function | |
● Communication Function | No |
● Other Measurement Function | No |
Net Weight | 1.375 kg |
Article Number | 3VA1163-5GF46-0AA0 |
Product Brand Name | SENTRON |
Product Designation | Molded case circuit breaker |
Product Version | Line protection |
Design of the Over-current Release | TM240 |
Protection Function of the Over-current Release | LI |
Number of Poles | 4 |
General Technical Data | |
Insulation Voltage / Rated Value | 800 V |
Max. Rated Operational Voltage Ue with DC | 600 V |
Operating Voltage / at AC / Rated Value | 690 V |
Power Loss [W] / Maximum | 17.3 W |
Active Power Loss / for Rated Value of the Current / at AC / in Hot Operating State / Per Pole | 5.77 W |
Mechanical Service Life (Switching Cycles) / Typical 380/415 V 50/60 Hz | 20 000 |
Electrical Endurance (Switching Cycles) / at AC-1 / at 380/415 V 50/60 Hz | 9 000 |
Electrical Endurance (Switching Cycles) / at AC-1 / at 690 V 50/60 Hz | 6 300 |
Neutral Conductors / Upgradeable/Retrofittable | No |
Ground-Fault Monitoring Version | Without |
Product Function | |
● Communication Function | No |
● Other Measurement Function | No |
Net Weight | Net Weight 1.17 k |
Article Number | 3VA2463-5HL42-0AA0 |
Product Brand Name | SENTRON |
Product Designation | Molded case circuit breaker |
Product Version | Line protection |
Design of the Over-current Release | ETU320 |
Protection Function of the Over-current Release | LI |
Number of Poles | 4 |
General Technical Data | |
Insulation Voltage / Rated Value | 800 V |
Operating Voltage / at AC / Rated Value | 690 V |
Power Loss [W] / Maximum | 162 W |
Active Power Loss / for Rated Value of the Current / at AC / in Hot Operating State / Per Pole | 54 W |
Mechanical Service Life (Switching Cycles) / Typical | 20 000 |
Electrical Endurance (Switching Cycles) / at AC-1 / at 380/415 V 50/60 Hz | 5 000 |
Electrical Endurance (Switching Cycles) / at AC-1 / at 690 V 50/60 Hz | 3 500 |
Neutral Conductors / Upgradeable/Retrofittable | No |
Ground-Fault Monitoring Version | Without |
Product Function | |
● Communication Function | No |
● Other Measurement Function | No |
Net Weight | 6.797 kg |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)