S8FS-C – S8FS-C075[][]J – Omron Switch Mode Power Supply
$ 28.75 – $ 29.67
SKU: N/A
Power rating |
Input voltage | Output voltage (VDC) |
Output current |
Built- in fan |
Model with terminal block facing forward |
---|---|---|---|---|---|
75 W | 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC *1) |
5 V | 14 A | None | S8FS-C07505J |
12 V | 6.2 A | S8FS-C07512J | |||
15 V | 5 A | S8FS-C07515J | |||
24 V | 3.2 A | S8FS-C07524J | |||
48 V | 1.6 A | S8FS-C07548J |
Note: You can use brackets that are sold separately to mount the Power Supplies to DIN Rail. Refer to Mounting Brackets
(Order Separately) on Data Sheet.
*1. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC.
*2. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 120 VAC, 200 to 240 VAC.
Ratings, Characteristics, and Functions
Power rating | 75 W | ||||||
---|---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | 48 V | ||
Efficiency * | 115 VAC input | 75% typ. | 83% typ. | 84% typ. | 87% typ. | 87% typ. | |
230 VAC input | 77% typ. | 83% typ. | 84% typ. | 87% typ. | 87% typ. | ||
Input | Voltage range * | Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
|||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | ||||||
Current * | 115 VAC input | 1.4 A typ. | |||||
230 VAC input | 0.83 A typ. | ||||||
Power factor | — | ||||||
Leakage current |
115 VAC input | 0.25 mA | 0.25 mA | 0.25 mA | 0.25 mA | 0.25 mA | |
230 VAC input | 0.60 mA | 0.60 mA | 0.60 mA | 0.60 mA | 0.60 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | |||||
230 VAC input | 32 A typ. | ||||||
Output | Rated Output Current | 14 A | 6.2 A | 5 A | 3.2 A | 1.6 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | ||||||
Ripple & Noise voltage * |
100 to 240 VAC input |
80 mVp-p max. |
110 mVp-p max. |
90 mVp-p max. |
110 mVp-p max. |
140 mVp-p max. |
|
Input variation influence * | 0.5% max. | ||||||
Load variation influence * | 1.0% max. | ||||||
Temperature variation influence |
100 to 240 VAC input |
0.03%/°C max. | |||||
Startup time * |
115 VAC input | 750 ms typ. | 720 ms typ. | 730 ms typ. | 750 ms typ. | 700 ms typ. | |
230 VAC input | 710 ms typ. | 680 ms typ. | 690 ms typ. | 690 ms typ. | 730 ms typ. | ||
Hold time * | 115 VAC input | 12 ms typ. | 13 ms typ. | 13 ms typ. | 14 ms typ. | 15 ms typ. | |
230 VAC input | 75 ms typ. | 74 ms typ. | 74 ms typ. | 76 ms typ. | 78 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | |||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
||||||
Overheat protection | No | ||||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | ||||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | ||||||
Remote sensing | No | ||||||
Remote control | No | ||||||
Output indicator | Yes (LED: Green) | ||||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
|||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
|||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
|||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
||||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
|||||
Storage temperature | -40 to 85°C (with no condensation or icing) | ||||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | ||||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
||||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | ||||||
Relia- bility |
MTBF | 135,000 hrs min. | |||||
Life expectancy * | 10 years min. | ||||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | |||||
Weight | 350 g max. | ||||||
Cooling fan | No | ||||||
Degree of protection | — | ||||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | |||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||||
EMS | Conforms to EN 61204-3 high severity levels | ||||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) |
||||||
Marine Standards | No | ||||||
SEMI | No |
Weight | N/A |
---|---|
Model | S8FS-C07505J, S8FS-C07512J |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details