S8FS-C – S8FS-C025[][] – Omron Switch Mode Power Supply
$ 16.72 – $ 19.14
SKU: N/A
Power rating |
Input voltage | Output voltage (VDC) |
Output current |
Built- in fan |
Model with terminal block facing upward |
---|---|---|---|---|---|
25 W | 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC *1) |
5 V | 5 A | None | S8FS-C02505 |
12 V | 2.1 A | S8FS-C02512 | |||
15 V | 1.7 A | S8FS-C02515 | |||
24 V | 1.1 A | S8FS-C02524 |
Note: You can use brackets that are sold separately to mount the Power Supplies to DIN Rail. Refer to Mounting Brackets
(Order Separately) on Data Sheet.
*1. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC.
*2. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 120 VAC, 200 to 240 VAC.
Ratings, Characteristics, and Functions
Power rating | 25 W | |||||
---|---|---|---|---|---|---|
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | ||
Efficiency * | 115 VAC input | 80% typ. | 84% typ. | 85% typ. | 86% typ. | |
230 VAC input | 82% typ. | 86% typ. | 88% typ. | 88% typ. | ||
Input | Voltage range * | Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
||||
Frequency * | 50 /60 Hz (47 to 450 Hz) | |||||
Current * | 115 VAC input | 0.49 A typ. | ||||
230 VAC input | 0.3 A typ. | |||||
Power factor | — | |||||
Leakage current |
115 VAC input | 0.10 mA | 0.10 mA | 0.10 mA | 0.10 mA | |
230 VAC input | 0.20 mA | 0.20 mA | 0.20 mA | 0.20 mA | ||
Inrush current * (for a cold start at 25°) |
115 VAC input | 16 A typ. | ||||
230 VAC input | 32 A typ. | |||||
Output | Rated Output Current | 5 A | 2.1 A | 1.7 A | 1.1 A | |
Voltage adjustment range * | -10% to 10% (with V. ADJ) | |||||
Ripple & Noise voltage * |
100 to 240 VAC input |
20 mVp-p max. | 20 mVp-p max. | 30 mVp-p max. | 40 mVp-p max. | |
Input variation influence * | 0.5% max. | |||||
Load variation influence * | 1.0% max. | |||||
Temperature variation influence |
100 to 240 VAC input |
0.03%/°C max. | ||||
Startup time * |
115 VAC input | 390 ms typ. | 340 ms typ. | 400 ms typ. | 360 ms typ. | |
230 VAC input | 360 ms typ. | 350 ms typ. | 400 ms typ. | 360 ms typ. | ||
Hold time * | 115 VAC input | 17 ms typ. | 22 ms typ. | 23 ms typ. | 21 ms typ. | |
230 VAC input | 103 ms typ. | 113 ms typ. | 117 ms typ. | 112 ms typ. | ||
Addi- tional func- tions |
Overload protection | Yes, automatic reset | ||||
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||
Overheat protection | No | |||||
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) | |||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | |||||
Remote sensing | No | |||||
Remote control | No | |||||
Output indicator | Yes (LED: Green) | |||||
Insula- tion |
Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||
Envi- ron- ment |
Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
||||
Storage temperature | -40 to 85°C (with no condensation or icing) | |||||
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) | |||||
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
|||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||||
Relia- bility |
MTBF | 135,000 hrs min. | ||||
Life expectancy * | 10 years min. | |||||
Con- struc- tion |
Dimensions (W × H × D) | Refer to Dimensions. | ||||
Weight | 250 g max. | |||||
Cooling fan | No | |||||
Degree of protection | — | |||||
Stan- dards |
Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 | ||||
EMI | Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | ||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 | |||||
EMS | Conforms to EN 61204-3 high severity levels | |||||
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) |
|||||
Marine Standards | No | |||||
SEMI | No |
Weight | N/A |
---|---|
Model | S8FS-C02505, S8FS-C02512 |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details