The original SIMATIC power supplies harmonize perfectly with the PLC network in terms of their design and functionality. This ensures that controller and power supply are perfectly matched. In addition, the startup and power reserves of the power supply units meet the requirements of the respective controllers. The mounting options of both components are the same. The issued certifications and the permitted temperature range allow the components to be used together in almost all areas. The system test that was performed for each of the SITOP power supply units in SIMATIC design together with the respective SIMATIC controller is particularly noteworthy.
In addition to the following SIMATIC systems, the SITOP power supply units in SIMATIC design also supply further consumers reliably with 24 V.
Article number | 6EP1332-1SH71 | |
Product | S7-1200 PM1207 | |
Power supply, type | 24 V/2.5 A | |
Input | ||
type of the power supply network | 1-phase AC | |
supply voltage at AC | ||
● initial value | Automatic range selection | |
supply voltage | ||
● 1 at AC rated value | 120 V | |
● 2 at AC rated value | 230 V | |
input voltage | ||
● 1 at AC | 85 … 132 V | |
● 2 at AC | 176 … 264 V | |
design of input wide range input | No | |
overvoltage overload capability | 2.3 × Vin rated, 1.3 ms | |
operating condition of the mains buffering | at Vin = 93/187 V | |
buffering time for rated value of the output current in the event of power failure minimum | 20 ms | |
operating condition of the mains buffering | at Vin = 93/187 V | |
line frequency | ||
● 1 rated value | 50 Hz | |
● 2 rated value | 60 Hz | |
line frequency | 47 … 63 Hz | |
input current | ||
● at rated input voltage 120 V | 1.2 A | |
● at rated input voltage 230 V | 0.67 A | |
current limitation of inrush current at 25 °C maximum | 13 A | |
duration of inrush current limiting at 25 °C | ||
● maximum | 3 ms | |
I2t value maximum | 0.5 A²·s | |
fuse protection type | T 3,15 A/250 V (not accessible) | |
● in the feeder | Recommended miniature circuit breaker: 16 A characteristic B or 10 A characteristic C | |
Output | ||
voltage curve at output | Controlled, isolated DC voltage | |
output voltage at DC rated value | 24 V | |
output voltage | ||
● at output 1 at DC rated value | 24 V | |
relative overall tolerance of the voltage | 3 % | |
relative control precision of the output voltage | ||
● on slow fluctuation of input voltage | 0.1 % | |
● on slow fluctuation of ohm loading | 0.2 % | |
residual ripple | ||
● maximum | 150 mV | |
voltage peak | ||
● maximum | 240 mV | |
product function output voltage adjustable | No | |
type of output voltage setting | – | |
display version for normal operation | Green LED for 24 V OK | |
behavior of the output voltage when switching on | No overshoot of Vout (soft start) | |
response delay maximum | 6 s; 2 s at 230 V, 6 s at 120 V | |
voltage increase time of the output voltage | ||
● typical | 10 ms | |
output current | ||
● rated value | 2.5 A | |
● rated range | 0 … 2.5 A | |
supplied active power typical | 60 W | |
short-term overload current | ||
● on short-circuiting during the start-up typical | 6 A | |
● at short-circuit during operation typical | 6 A | |
duration of overloading capability for excess current | ||
● on short-circuiting during the start-up | 100 ms | |
● at short-circuit during operation | 100 ms | |
product feature | ||
● bridging of equipment | Yes | |
number of parallel-switched equipment resources for increasing the power | 2 | |
Efficiency | ||
efficiency in percent | 83 % | |
power loss [W] | ||
● at rated output voltage for rated value of the output current typical | 12 W | |
Closed-loop control | ||
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical | 0.3 % | |
relative control precision of the output voltage load step of resistive load 50/100/50 % typical | 3 % | |
setting time | ||
● load step 50 to 100% typical | 5 ms | |
● load step 100 to 50% typical | 5 ms | |
setting time | ||
● maximum | 5 ms | |
Protection and monitoring | ||
design of the overvoltage protection | < 33 V | |
response value current limitation typical | 2.65 A | |
property of the output short-circuit proof | Yes | |
design of short-circuit protection | Constant current characteristic | |
enduring short circuit current RMS value | ||
● typical | 2.7 A | |
display version for overload and short circuit | – | |
Safety | ||
galvanic isolation between input and output | Yes | |
galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | |
operating resource protection class | Class I | |
leakage current | ||
● maximum | 3.5 mA | |
protection class IP | IP20 | |
Approvals | ||
certificate of suitability | ||
● CE marking | Yes | |
● UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950-1, CSA C22.2 No. 60950-1) File E151273 | |
● CSA approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950-1, CSA C22.2 No. 60950-1) File E151273 | |
● cCSAus, Class 1, Division 2 | No | |
● ATEX | Yes; ATEX (EX) II 3G Ex nA nC IIC T4 Gc | |
certificate of suitability | ||
● relating to ATEX | IECEx Ex nA nC IIC T4 Gc; ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cULus (ISA 12.12.01, CSA C22.2 No.213) Class I, Div. 2, Group ABCD, T4, File E330455 | |
● IECEx | Yes; IECEx Ex nA nC IIC T4 Gc | |
● NEC Class 2 | No | |
● ULhazloc approval | Yes | |
● FM registration | Yes; Class I, Div. 2, Group ABCD, T4 | |
type of certification CB-certificate | Yes | |
certificate of suitability | ||
● EAC approval | Yes | |
certificate of suitability shipbuilding approval | Yes | |
shipbuilding approval | ABS, BV, DNV GL, LRS, NK | |
Marine classification association | ||
● American Bureau of Shipping Europe Ltd. (ABS) | Yes | |
● French marine classification society (BV) | Yes | |
● DNV GL | Yes | |
● Lloyds Register of Shipping (LRS) | Yes | |
● Nippon Kaiji Kyokai (NK) | Yes | |
EMC | ||
standard | ||
● for emitted interference | EN 55022 Class B | |
● for mains harmonics limitation | not applicable | |
● for interference immunity | EN 61000-6-2 | |
environmental conditions | ||
ambient temperature | ||
● during operation | 0 … 60 °C; with natural convection | |
● during transport | -40 … +85 °C | |
● during storage | -40 … +85 °C | |
environmental category according to IEC 60721 | Climate class 3K3, 5 … 95% no condensation | |
Mechanics | ||
type of electrical connection | screw-type terminals | |
● at input | L, N, PE: 1 screw terminal each for 0.5 … 2.5 mm² | |
● at output | L+, M: 2 screw terminals each for 0.5 … 2.5 mm² | |
● for auxiliary contacts | – | |
width of the enclosure | 70 mm | |
height of the enclosure | 100 mm | |
depth of the enclosure | 75 mm | |
required spacing | ||
● top | 20 mm | |
● bottom | 20 mm | |
● left | 0 mm | |
● right | 0 mm | |
net weight | 0.3 kg | |
product feature of the enclosure housing can be lined up | Yes | |
fastening method | Snaps onto DIN rail EN 60715 35×7.5/15, wall mounting | |
MTBF at 40 °C | 1 492 537 h | |
other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
Weight | 0.3 kg |
---|---|
Dimensions | 8 × 10.5 × 7.5 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)