$ 110.66
Inosaki – Your Trusted Phoenix Contact Distributor
Inosaki proudly stands as one of the largest distributors of Phoenix Contact products, offering a comprehensive range of terminal blocks, interface modules, power supplies, and relays.
Series Models: PT Series, ST Series, TB Series, UT Series, and UK Series, PTV Series, UKH Series, Micro Series.
Discover industry-leading Phoenix Contact power supplies, such as:
Get Your Phoenix Contact Catalog Today
Need detailed product information? Contact us at sales@inosaki.com to request your Phoenix Contact catalog.
In the power range of up to 100 W, QUINT POWER provides superior system availability in the smallest size. Preventative function monitoring and exceptional power reserves are available for applications in the low-power range.
Article Number | 2904598 |
---|---|
Width | 32 mm |
Height | 99 mm |
Depth | 90 mm |
Installation distance right/left (passive) | 5 mm / 5 mm (POut ≥50% ) |
Installation distance right/left (active) | 15 mm / 15 mm (POut ≥50% ) |
Installation distance top/bottom (active, passive) | 30 mm / 30 mm (POut ≤50 %) |
Installation distance top/bottom (passive) | 30 mm / 30 mm (POut ≥50% ) |
Installation distance top/bottom (active) | 30 mm / 30 mm (POut ≥50% ) |
Degree of protection | IP20 |
---|---|
Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 |
Ambient temperature (operation) | -25 °C … 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | ≤ 5000 m (> 2000 m, observe derating) |
Input voltage range | 100 V AC … 240 V AC -15 % … +10 % |
---|---|
110 V DC … 250 V DC -20 % … +40 % | |
Dielectric strength maximum | 300 V AC 30 s |
Frequency range (fN) | 50 Hz … 60 Hz -10 % … +10 % |
Discharge current to PE | < 0.25 mA (264 V AC, 60 Hz) |
Current consumption | 0.85 A (100 V AC) |
0.7 A (120 V AC) | |
0.39 A (230 V AC) | |
0.37 A (240 V AC) | |
Nominal power consumption | 71 VA |
Inrush current | typ. 10 A (at 25 °C) |
Mains buffering time | typ. 54 ms (120 V AC) |
typ. 54 ms (230 V AC) | |
Input fuse | 3.15 A (slow-blow, internal) |
Recommended breaker for input protection | 6 A … 16 A (Characteristic B, C or comparable) |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Nominal output voltage | 24 V DC |
---|---|
Setting range of the output voltage (USet) | 24 V DC … 28 V DC (constant capacity) |
Nominal output current (IN) | 2.5 A |
Static Boost (IStat.Boost) | 3.125 A (≤ 40 °C) |
Dynamic Boost (IDyn.Boost) | 5 A (≤60 °C (5 s), Input <150 V AC Derating 0.5 %/V) |
Derating | > 60 °C (2.5%/K) |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback voltage resistance | ≤ 35 V DC |
Protection against overvoltage at the output (OVP) | ≤ 32 V DC |
Control deviation | < 0.5 % (Static load change 10 % … 90 %) |
< 2 % (Dynamic load change 10 % … 90 %, (10 Hz)) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 40 mVPP (with nominal values) |
Output power | 60 W |
Typical response time | 500 ms |
Maximum power dissipation in no-load condition | < 1 W (230 V AC) |
< 1 W (120 V AC) | |
Power loss nominal load max. | < 5 W (230 V AC) |
< 5 W (120 V AC) |
Net weight | 0.244 kg |
---|---|
Environmental protection directive | RoHS Directive 2011/65/EU |
WEEE | |
Reach | |
Efficiency | typ. 91.9 % (120 V AC) |
typ. 92.6 % (230 V AC) | |
MTBF (IEC 61709, SN 29500) | > 1347000 h (25 °C) |
> 734000 h (40 °C) | |
> 295000 h (60 °C) | |
Insulation voltage input/output | 4 kV AC (type test) |
3 kV AC (routine test) | |
Degree of protection | IP20 |
Protection class | II |
Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 |
Assembly instructions | DIN rail mounting |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.14 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.14 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 26 |
Conductor cross section AWG max. | 14 |
Stripping length | 8 mm |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.14 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.14 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 26 |
Conductor cross section AWG max. | 14 |
Stripping length | 8 mm |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.14 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.14 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 26 |
Conductor cross section AWG max. | 14 |
Stripping length | 8 mm |
EMC requirements for noise immunity | EN 61000-6-1 |
---|---|
EN 61000-6-2 | |
EMC requirements for noise emission | EN 61000-6-3 |
EN 61000-6-4 | |
EMC requirements, power plant | IEC 61850-3 |
EN 61000-6-5 | |
Standard – Safety of transformers | EN 61558-2-16 |
Standard – Electrical safety | IEC 61010-2-201 (SELV) |
Standard – safety for equipment for measurement, control, and laboratory use | IEC 61010-1 |
Standard – Safety extra-low voltage | IEC 61010-1 (SELV) |
IEC 61010-2-201 (PELV) | |
Standard – Safe isolation | IEC 61558-2-16 |
Standard – power supply devices for low voltage with DC output | EN 61204-3 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Overvoltage category EN 61010-1 | II (≤ 5000 m) |
Overvoltage category EN 62477-1 | III (≤ 2000 m) |
UL approvals | UL Listed UL 61010-1 |
---|---|
UL Listed UL 61010-2-201 | |
UL 1310 Class 2 Power Units | |
ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
SIQ | CB-Scheme (IEC 61010-1, IEC 61010-2-201) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Conducted noise emission | EN 55016 |
EN 61000-6-3 (Class B) | |
Noise emission | EN 55016 |
EN 61000-6-3 (Class B) | |
Electrostatic discharge | EN 61000-4-2 |
Contact discharge | 8 kV (Test Level 4) |
Discharge in air | 8 kV (Test Level 3) |
Electromagnetic HF field | EN 61000-4-3 |
Frequency range | 80 MHz … 1 GHz |
Test field strength | 20 V/m |
Frequency range | 1 GHz … 6 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst) | EN 61000-4-4 |
Input | 4 kV (Test Level 4 – asymmetrical) |
Output | 4 kV (Test Level 4 – asymmetrical) |
Signal | 4 kV (Test Level 4 – asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge) | EN 61000-4-5 |
Input | 2 kV (Test Level 4 – symmetrical) |
4 kV (Test Level 4 – asymmetrical) | |
Output | 1 kV (Test Level 3 – symmetrical) |
2 kV (Test Level 3 – asymmetrical) | |
Signal | 2 kV (Test Level 4 – symmetrical) |
Comments | Criterion A |
Conducted interference | EN 61000-4-6 |
I/O/S | asymmetrical |
Frequency range | 0.15 MHz … 80 MHz |
Voltage | 10 V (Test Level 3) |
Comments | Criterion A |
Power frequency magnetic field | EN 61000-4-8 |
Frequency | 16.67 Hz |
50 Hz | |
60 Hz | |
Test field strength | 100 A/m |
Additional text | 60 s |
Comments | Criterion A |
Frequency | 50 Hz |
60 Hz | |
Frequency range | 50 Hz … 60 Hz |
Test field strength | 1 kA/m |
Additional text | 3 s |
Frequency | 0 Hz |
Test field strength | 300 A/m |
Additional text | DC, 60 s |
Voltage dips | EN 61000-4-11 |
Voltage | 100 V AC |
Frequency | 60 Hz |
Voltage dip | 70 % |
Number of periods | 0.5 / 1 / 25 periods |
Additional text | Test Level 2 |
Comments | Criterion B |
Voltage dip | 40 % |
Number of periods | 5 / 10 / 50 periods |
Additional text | Test Level 2 |
Comments | Criterion B |
Voltage dip | 0 % |
Number of periods | 0.5 / 1 / 5 / 50 periods |
Additional text | Test Level 2 |
Comments | Criterion B |
Pulse-shape magnetic field | EN 61000-4-9 |
Test field strength | 1000 A/m |
Comments | Criterion A |
Attenuated sinusoidal oscillations (ring wave) | EN 61000-4-12 |
Input | 2 kV (symmetrical) |
4 kV (asymmetrical) | |
Comments | Criterion B |
Asymmetrical conducted disturbance variables | EN 61000-4-16 |
Test level 1 | 16.67 Hz 50 Hz 60 Hz (Test Level 3) |
Voltage | 30 V (Permanent) |
Test level 2 | 16.67 Hz 50 Hz 60 Hz (Test Level 4) |
Voltage | 300 V (1 s) |
Comments | Criterion A |
Attenuated oscillating wave | EN 61000-4-18 |
Comments | Criterion B |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 25; |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)