Contact Us:
sales@inosaki.com

QUINT-PS/3AC/24DC/10 – 2866705 – Phoenix Contact Power Supply

$ 417.78

SKU Phoenix Contact 2866705 Category

Inosaki – Your Trusted Phoenix Contact Distributor
Inosaki proudly stands as one of the largest distributors of Phoenix Contact products, offering a comprehensive range of terminal blocks, interface modules, power supplies, and relays.

Our Best-Selling Terminal Blocks: Feed-Through, Fuse Modular, Spring Cage, Double Level, Multi-Level

Series Models: PT Series, ST Series, TB Series, UT Series, and UK Series, PTV Series, UKH Series, Micro Series.

Reliable Power Supply Solutions

Discover industry-leading Phoenix Contact power supplies, such as:

  • QUINT Power – Premium performance for critical systems
  • STEP Power – Compact design for space-saving applications
  • Trio Power – Rugged and reliable for industrial needs
  • UNO Power – Cost-effective and efficient

Get Your Phoenix Contact Catalog Today
Need detailed product information? Contact us at sales@inosaki.com to request your Phoenix Contact catalog.

Product Description

QUINT POWER power supplies with maximum functionality
QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur.
Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V DC … 56 V DC are covered.

 

Dimensions

Width 60 mm
Height 130 mm
Depth 125 mm
Installation dimensions
Installation distance right/left (active) 15 mm / 15 mm
Installation distance top/bottom (active) 50 mm / 50 mm

 

Alternative assembly

Width 122 mm
Height 130 mm
Depth 63 mm

 

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C … 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport) -40 °C … 85 °C
Ambient temperature (start-up type tested) -40 °C
Maximum altitude 4500 m
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz … 150 Hz, 2.3g, 90 min.

 

Input data

Nominal input voltage range 3x 400 V AC … 500 V AC
Input voltage range 3x 320 V AC … 575 V AC
2x 360 V AC … 575 V AC
450 V DC … 800 V DC
Input voltage range DC 450 V DC … 800 V DC
Voltage type of supply voltage AC/DC
Inrush current < 15 A (typical)
Inrush current integral (I2t) < 1.5 A2s
AC frequency range 45 Hz … 65 Hz
Frequency range DC 0 Hz
Mains buffering time > 30 ms (400 V AC)
> 46 ms (500 V AC)
Current consumption 3x 1.2 A (400 V AC)
3x 1 A (500 V AC)
0.4 A (600 V DC)
Nominal power consumption 411 VA
Protective circuit Transient surge protection; Varistor, gas-filled surge arrester
Power factor (cos phi) 0.62
Typical response time < 0.45 s
Permissible backup fuse B6 B10 B16 AC:
Permissible DC backup fuse DC: Connect a suitable fuse upstream
Recommended breaker for input protection 6 A … 16 A (AC: Characteristics B, C, D, K)
Discharge current to PE < 3.5 mA

 

Output data

Efficiency > 93 % (at 400 V AC and nominal values)
Output characteristic U/I
Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 18 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN) 10 A (-25 °C … 60 °C, UOUT = 24 V DC)
POWER BOOST (IBoost) 15 A (-25 °C … 40 °C permanent, UOUT = 24 V DC )
Selective Fuse Breaking (ISFB) 60 A (12 ms)
Magnetic circuit breaker tripping B2 / B4 / B6 / C2 / C4
Derating 60 °C … 70 °C (2.5%/K)
Feedback voltage resistance max. 35 V DC
Protection against overvoltage at the output (OVP) < 35 V DC
Control deviation < 1 % (change in load, static 10 % … 90 %)
< 3 % (change in load, dynamic 10 % … 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 20 mVPP (with nominal values)
Output power 240 W
Peak switching voltages nominal load < 20 mVPP (at nominal values, 20 MHz)
Maximum no-load power dissipation 7 W
Power loss nominal load max. 19 W
Rise time < 0.15 s (UOUT (10 % … 90 %))
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes

 

Signal: DC OK active

Output description UOUT > 0.9 x UN: High signal
Maximum switching voltage + 24 V DC
Switching voltage range 18 V DC … 24 V DC
Output voltage + 24 V DC
Maximum inrush current ≤ 20 mA (short-circuit-proof)
Continuous load current ≤ 20 mA

 

Signal: DC OK floating

Output description Relay contact, UOUT > 0.9 x UN: Contact closed
Maximum switching voltage 30 V AC/DC
24 V DC
Maximum inrush current 0.5 A
1 A
Continuous load current ≤ 1 A

 

Signal: POWER BOOST, active

Output description IOUT < IN: High signal
Maximum switching voltage + 24 V DC
Switching voltage range 18 V DC … 24 V DC
Output voltage + 24 V DC
Maximum inrush current ≤ 20 mA (short-circuit-proof)
Continuous load current ≤ 20 mA

 

Connection data, input

Connection method Pluggable screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 16
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

 

Connection data, output

Connection method Pluggable screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 16
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

 

Connection data for signaling

Connection method Pluggable screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 16
Conductor cross section AWG max. 12
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

 

Standards and Regulations

Rail applications EN 50121-4
EN 50121-3-2
Standard – Limitation of mains harmonic currents EN 61000-3-2
Standard – Electrical safety IEC 61010-2-201 (SELV)
Standard – Equipment safety GS (tested safety)
Standard – Approval for medical use IEC 60601-1, 2 x MOOP
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Safety extra-low voltage IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard – Safe isolation IEC 61010-2-201
Standard – safety for equipment for measurement, control, and laboratory use IEC 61010-1
Standard – surge resistance VDE 0160 (curve W2)
Approval – requirement of the semiconductor industry with regard to mains voltage dips SEMI F47-0706 Compliance Certificate
Overvoltage category
EN 62477-1 III

 

EMC Data

Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Comments Criterion A
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz … 1 GHz
Test field strength 20 V/m (Test Level 3)
Frequency range 1 GHz … 2 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 2 GHz … 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input 4 kV (Test Level 4 – asymmetrical)
Output 2 kV (Test Level 3 – asymmetrical)
Signal 2 kV (Test Level 4 – asymmetrical)
Comments Criterion A
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Input 3 kV (Test Level 3 – symmetrical)
6 kV (Test Level 4 – asymmetrical)
Output 1 kV (Test Level 2 – symmetrical)
2 kV (Test Level 3 – asymmetrical)
Signal 1 kV (Test Level 2 – asymmetrical)
Comments Criterion A
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
I/O/S asymmetrical
Frequency range 0.15 MHz … 80 MHz
Comments Criterion A
Voltage 10 V (Test Level 3)
Emitted interference
Standards/regulations EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.

Additional information

Weight 1.100 kg
Dimensions 12.50 × 6.0 × 13.00 cm

Related Products

c-mount_lens_25mm_tamron_6megapixel_ids_ueye-3
SICK_Compact Photoelectric Sensors-WTB9-3N2461
SIEMENS_SINAMICS V20 Basic Converter-Frame Sze FSAC
Omron_End Cover_NX-END01
$ 16.72 - $ 17.82
camera-ueye-se-usb3
IDS_10G POE+ PCie Card, 1 Port, RJ45
Select your currency