Contact Us:
sales@inosaki.com

QUINT-DIODE/12-24DC/2X20/1X40 – 2320157 – Phoenix Contact Redundancy Modules

$ 140.14

SKU Phoenix Contact 2320157 Category

Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.

Product Description

A safe redundant system is the result of the parallel connection of two power supply units which are decoupled from one another. To further increase system availability, QUINT DIODE provides the solution: decoupling with diode.

Dimensions

Width 50 mm
Height 130 mm
Depth 125 mm
Horizontal pitch 2.8 Div.
Installation dimensions
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm

Ambient Conditions

Degree of protection IP20
Ambient temperature (operation) -40 °C … 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport) -40 °C … 85 °C
Maximum altitude ≤ 5000 m
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz … 150 Hz, 2.3g, 90 min.

Input Data

Nominal input voltage range 12 V DC … 24 V DC
Input voltage range 10 V DC … 30 V DC
Voltage type of supply voltage DC
Reverse polarity protection < yes60 V
Nominal input current (IN) 2x 20 A (-25 °C … 60 °C)
1x 40 A (-25 °C … 60 °C)
Maximum current Imax 2x 30 A (-25°C … 40°C)
1x 60 A (-25°C … 40°C)
Transient surge protection Varistor
Voltage drop, input/output typ. 0.5 V
Nominal input voltage range 12 V DC … 24 V DC
Input voltage range 10 V DC … 30 V DC
Input voltage range DC 10 V DC … 30 V DC

Output Data

Efficiency > 97 %
> 97 %
Output voltage UIn 
Nominal output current (IN) 40 A (Increasing power)
20 A (Redundancy)
Derating 60 °C … 70 °C (2.5%/K)
Power loss nominal load max. 10 W (IOUT = 20 A)
Connection in series No
Derating 60 °C … 70 °C 2.5 %/K

Commercial Data

Item number 2320157
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key C15
Product Key CMRQ43
Catalog Page Page 212 (C-6-2015)
GTIN 4046356524766
Weight per Piece (including packing) 857.6 g
Weight per Piece (excluding packing) 750 g
Customs tariff number 85049090
Country of origin CN

Connection Data, Input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 12
Conductor cross section AWG max. 10
Stripping length 8 mm
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

Connection Data, Output

Connection method Screw connection
Conductor cross section solid min. 0.5 mm²
Conductor cross section solid max. 16 mm²
Conductor cross section flexible min. 0.5 mm²
Conductor cross section flexible max. 16 mm²
Conductor cross section AWG min. 10
Conductor cross section AWG max. 6
Stripping length 10 mm
Screw thread M4
Tightening torque, min 1.2 Nm
Tightening torque max 1.5 Nm

Standards and Regulations

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Safe isolation DIN VDE 0100-410

Conformance/Approvals

UL approvals UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Conformity/Approvals
ATEX  II 3 G Ex ec IIC T4 Gc
DEKRA 20ATEX0041 X
IECEx Ex ec IIC T4 Gc
IECEx DEK 20.0022X

EMC Data

Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
Electrostatic discharge
Standards/regulations EN 61000-4-2
Housing Level 4
Electrostatic discharge
Contact discharge 8 kV (Contact discharge)
Discharge in air 15 kV (Air discharge)
Comments Criterion A
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz … 1 GHz
Test field strength 20 V/m
Frequency range 1 GHz … 3 GHz
Test field strength 10 V/m
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input 2 kV (level 3 – asymmetrical: conductor to ground)
Output 2 kV (level 3 – asymmetrical: conductor to ground)
Comments Criterion A
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
Input/Output Level 3
Frequency range 0.15 MHz … 80 MHz
Comments Criterion A
Voltage 10 V
Emitted interference
Standards/regulations EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Additional information

Weight 0.8576 kg
Dimensions 12.5 × 5 × 13 cm

Related Products

SCHNEIDER_Maintaining Clamp,Harmony,for RXM Sockets,Metal
THK__LINEAR MOTION_SSR-XW Block
Festo_Pneumatic fittings _NPCK-C-D-G18-K6_1366257
Festo_Piston rod cylinders_ADN-20-42-I-PPS-A-536233-02
c-mount_lens_16mm_tamron_6megapixel_ids_ueye-3
M24 -1
Select your currency