Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
General | |
Rated control circuit supply voltage US | 24 V AC/DC -15 % / +10 % |
Power consumption at US | typ. 3.36 W (AC) |
typ. 1.56 W (DC) | |
Rated control supply current IS | typ. 140 mA AC |
typ. 65 mA DC | |
Inrush current | 2 A (Δt = 10 ms at Us) |
< 40 mA (with Us/Ix to S34) | |
Current consumption | < 50 mA (with Us/Ix to S12) |
0 mA (with Us/Ix to S34) | |
Voltage at input/start and feedback circuit | 24 V DC -15 % / +10 % |
Filter time | 2 ms (at A1 in the event of voltage dips at Us) |
max. 1.5 ms (at S12; test pulse width) | |
7.5 ms (at S12; test pulse rate) | |
Test pulse rate = 5 x Test pulse width | |
Typical response time | < 65 ms (automatic start) |
< 40 ms (manual start) | |
Typ. starting time with Us | < 65 ms (when controlled via A1) |
Typical release time | < 45 ms (when controlled via S12) |
< 200 ms (when controlled via A1) | |
Recovery time | < 1 s |
Maximum switching frequency | 1 Hz |
Protective circuit | Surge protection; Suppressor diode |
Protection against polarity reversal for rated control circuit supply voltage | |
Max. permissible overall conductor resistance | approx. 22 Ω (Input and start circuits at US) |
Operating voltage display | 1 x green LED |
Status display | 2 x green LEDs |
Contact type | 4 enabling current paths |
1 signaling current path | |
Contact material | AgSnO2 |
Maximum switching voltage | 250 V AC/DC (Observe the load curve) |
Minimum switching voltage | 5 V AC/DC |
Limiting continuous current | 6 A (N/O contact, pay attention to the derating) |
6 A (N/C contact) | |
Maximum inrush current | 20 A (Δt 100 ms) |
Inrush current, minimum | 10 mA |
Sq. Total current | 72 A2 (observe derating) |
Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
288 W (48 V DC, τ = 0 ms) | |
110 W (110 V DC, τ = 0 ms) | |
88 W (220 V DC, τ = 0 ms) | |
1500 VA (250 V AC, τ = 0 ms) | |
Maximum interrupting rating (inductive load) | 42 W (24 V DC, τ = 40 ms) |
42 W (48 V DC, τ = 40 ms) | |
42 W (110 V DC, τ = 40 ms) | |
42 W (220 V DC, τ = 40 ms) | |
Switching capacity min. | 50 mW |
Switching capacity (360/h cycles) | 4 A (24 V DC) |
4 A (230 V AC) | |
Switching capacity (3600/h cycles) | 2.5 A (24 V (DC13)) |
3 A (230 V (AC15)) | |
Output fuse | 10 A gL/gG (N/O contact) |
6 A gL/gG (N/C contact) |
Connection technology | |
pluggable | yes |
Conductor connection | |
Connection method | Screw connection |
Conductor cross section solid | 0.2 mm² … 2.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
Conductor cross-section AWG | 24 … 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Item number | 2963802 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product Key | DNA111 |
Catalog Page | Page 229 (C-6-2019) |
GTIN | 4017918892661 |
Weight per Piece (including packing) | 212.4 g |
Weight per Piece (excluding packing) | 210.5 g |
Customs tariff number | 85371098 |
Country of origin | DE |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient temperature (operation) | -20 °C … 65 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C … 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (operation) | 10 Hz … 150 Hz, 2g |
Weight | 212.4 kg |
---|---|
Dimensions | 11.45 × 2.25 × 9.9 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)