Main information |
Part Number |
XCSPR751 |
Product Series |
Telemecanique Safety switches XCS |
product type |
Guard switch |
component name |
XCSPR |
Material |
Plastic |
Control head type |
Hex head rotary shaft |
isolation |
Double insulation |
operator type |
Shaft 30mm |
Electrical connections |
Terminal |
Contact type and composition |
1 NC + 1 NC |
contact action |
Slow break |
locking force |
1 x 0.5…2 x 1.5 mm² with or without cable end |
cable entry hole |
1 Perforated cable entry for Pg 11 |
number of poles |
2 |
Additional information |
Cable outer diameter |
7…10mm |
force open |
With NC contact |
Trip angle |
5° |
Mechanical life |
1000000 times |
Minimum trigger torque |
0.1 Nm |
Force open minimum torque |
0.25 Nm |
Contact wire regulation grade |
A300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1 |
A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 |
Q300, DC-13 (Ue = 126 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1 Q300, |
DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 |
Conventional enclosed heating current [Ithe] |
10A |
Rated insulation voltage [Ui] |
300 V conforming to UL 508 |
300 V conforming to CSA C22.2 No 14 |
500 V (pollution degree 3) conforming to EN/IEC 60947-1 |
Rated impulse withstand voltage [Uimp] |
6 kV conforming to EN/IEC 60947-5-1 |
Maximum resistance across terminals |
30 mΩ conforming to EN/IEC 60947-5-4 |
Short circuit protection |
10 A fuse type gG (gl) |
Security Level |
Category 4 can be achieved with appropriate monitoring system and correct wiring according to EN/ISO 13849-1 |
PL = e can be achieved with appropriate monitoring system and correct wiring according to EN/ISO 13849-1 |
SIL 3 can be achieved with appropriate monitoring system and correct wiring according to IEC 61508 |
Safe and reliable data |
B10d = 5000000 Value determined by 20 years life time, limited by mechanical or contact wear |
Cabinet material |
Polyamide PA66 Glass fiber impregnated |
lever material |
Stainless steel |
width |
30 mm |
high |
96 mm |
depth |
60 mm |
product weight |
0.105kg |
Environment |
Standards compliant |
EN/IEC 60947-5-4 |
EN/IEC 60204-1 |
CSA C22.2 No 14 |
EN/ISO 12100 |
EN 1088/ISO 14119 |
EN/IEC 60947-5-1 |
UL 508 |
certified product |
CSA |
UL |
BG |
Protective treatment |
TC |
TH |
operating temperature |
-25…70°C |
storage environment temperature |
-40…70°C |
Anti-vibration |
50 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
impact resistance |
50 gn for 11 ms conforming to IEC 60068-2-27 |
Electric Shock Protection Level |
Class II conforms to EN/IEC 61140 |
IP protection class |
IP67 complies with screwed |
Packaging unit |
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
3.7cm |
Package 1 Width |
11.4 cm |
Package 1 Length |
11.4 cm |
Package 1 Weight |
137.0g |
Unit Type of Package 2 |
S02 |
Number of Units in Package 2 |
18 |
Package 2 Height |
15.0cm |
Package 2 Width |
30.0cm |
Package 2 Length |
40.0cm |
Package 2 Weight |
2.754 kg |
Contract warranty |
Warranty |
18 months |