Contact Us:
sales@inosaki.com

Preventa XPS – XPSAC – Safety Modules – Schneider Modules

$ 120.12

SKU XPSAC3721 Category

Specifications

Main
Part Number XPSAC3721
Product Series Preventa Security Automation
product type Preventa Security Module
Security module name XPSAC
Security Module Application Monitoring of emergency stops and switches
module function Emergency stop
switch monitoring
Security Level Can reach PL e/category 4 conforms to EN/ISO 13849-1
Can achieve SILCL 3 conforms to EN/IEC 62061
Safe and reliable data MTTFd = 210.4 years according to EN/ISO 13849-1
DC > 99 % according to EN/ISO 13849-1
PFHd = 3.56E-9 1/h according to EN/IEC 62061
startup type No monitoring
Wiring capacity Captive screw clamp terminal, 1 x 0.14…1 x 2.5 mm² flexible cable end with double frame
captive screw clamp terminal, 1 x 0.14…1 x 2.5 mm² rigid cable end with double frame captive
screw terminal Clamp terminal, 1 x 0.25…1 x 1.5 mm² flexible cable end with double frame
captive screw clamp terminal, 1 x 0.25…1 x 2.5 mm² flexible cable end with double frame
captive screw clamp terminal , 2 x 0.14…2 x0.75 mm² flexible with cable ends, with double frame
captive screw clamp terminals, 2 x 0.14…2 x0.75 mm² rigid with cable ends, with double frame
captive screw clamp terminals , 2 x 0.25…2 x 1 mm² flexible cord with cable end with double frame
captive screw clamp terminal, 2 x 0.5…2 x 1.5 mm² flexible cord with cable end with double frame
output type Relay Momentary Opening, 3 NO Circuits, Volt-free
Number of other loops 1 solid state output
Rated supply voltage [Us] 230V AC – 15…10 %
Additional information
power supply frequency 50/60Hz
Maximum power consumption in VA 6 VA AC
Control circuit voltage 230V
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA surge AC-15 C300 relay output
Breaking capacity 1.5 A at 24 V (DC-13) Time constant: 50 ms for relay output
output thermal current 6 A per relay for relay outputs
Conventional thermal current [Ith] 10.5A
Fuses for use with relays 4 A gG or gL for relay output acc. to EN/IEC 60947-5-1, DIN VDE 0660 part 2006
A fast fuse for relay output acc. to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA for relay output
Minimum output voltage 16 V for relay outputs
Maximum response time on input open 100ms
Rated insulation voltage [Ui] 300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
Rated impulse withstand voltage [Uimp] 4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1
local signal indication 2 leds
current consumption 25 mA on 230V AC mains
installation method 35 mm DIN rail
Product Weight 0.21kg
environment
Standards compliant EN/IEC 60947-5-1
EN/ISO 13850
EN 1088/ISO 14119
EN 60204-1
certified product TÜV
UL
CSA
IP protection class IP20 (screw terminals) conforming to EN/IEC 60529
IP40 (cabinet) conforming to EN/IEC 60529
operating temperature -10…55 °C
storage environment temperature -25…85°C
packaging unit
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.1 cm
Package 1 Width 2.8cm
Package 1 Length 10.5cm
Package 1 Weight 242.0g
Unit Type of Package 2 S01
Number of Units in Package 2 16
Package 2 Height 15.0cm
Package 2 Width 15.0cm
Package 2 Length 40.0cm
Package 2 Weight 4.204 kg
contract warranty
Warranty 18 months

 

Additional information

Weight 0.242 kg
Dimensions 10.5 × 2.8 × 12.1 cm

Related Products

Siemens_Buffer battery for Mobile Panel_6AV6671-5AD00-0AX0
QS18VN6LLPQ
SICK_sensor_Photoelectric_sensor_W12-2 Laser_WL12G-3V2572
Omron C200HW-COM03-V1
Festo_Shut off valves pneumatic_SE-1-2-B_9688
IDS_Camera_uEye_LE_MB_BoardLevel_C_Mount_1
Select your currency