$ 433.78
Boost system reliability with Phoenix Contact QUINT-ORING/24DC/2X40/1X80 redundancy module, ensuring balanced load, high efficiency, and nonstop operation.
The Phoenix Contact QUINT-ORING/24DC/2X40/1X80 redundancy module (2902879) is engineered to secure reliable power in demanding industrial applications. Designed for 24 V DC systems, it manages two inputs at 40 A each and provides a stable 80 A output. With its advanced Auto Current Balancing (ACB) function, the module ensures power supplies share the load evenly, extending their service life. High efficiency above 98% and continuous monitoring of system health make it ideal for preventing downtime. Compact DIN rail mounting and robust construction allow it to perform dependably in mission-critical environments.
The QUINT-ORING/24DC/2X40/1X80 redundancy module offers more than just power backup—it brings reliability, efficiency, and extended system longevity. Its ACB feature minimizes strain on individual power supplies, helping reduce maintenance and replacement costs. Built-in diagnostic monitoring quickly identifies issues, while selective fuse breaking technology safeguards downstream equipment during overloads. With durable housing and vibration-resistant design, it integrates smoothly into industrial cabinets. This solution is well suited for sectors such as automation, process control, and transportation where uninterrupted operation is essential. By combining energy efficiency with dependable protection, it helps businesses maintain safe and continuous production.
The Phoenix Contact QUINT-ORING/24DC/2X40/1X80 is the smart choice for industries that cannot afford downtime. It combines high current capability, compact DIN rail design, and Auto Current Balancing technology to keep power supplies running longer and more efficiently. With permanent system monitoring, it ensures engineers have peace of mind knowing critical equipment is always protected and operational.
This redundancy module tackles the common issue of uneven load sharing and sudden power failures in industrial systems. By balancing currents between power supplies and detecting faults before they cause disruption, it prevents unplanned downtime, costly repairs, and production losses. In short, it transforms fragile power setups into a robust, continuous, and maintenance-friendly energy supply system.
Feature | Details | Benefit |
---|---|---|
Input Voltage Range | 18–28 V DC | Flexible operation in varying supply conditions |
Nominal Input Current | 2x 40 A | Supports dual supply redundancy |
Nominal Output Current | 1x 80 A | High current capacity for critical loads |
Efficiency | >98% | Reduces energy loss and operating cost |
Auto Current Balancing (ACB) | Yes | Doubles power supply service life by even load sharing |
Redundancy Monitoring | Integrated with LED status | Early fault detection for maximum system availability |
Selective Fuse Breaking (SFB) | 430 A (12 ms) | Fast disconnection during short circuits for equipment protection |
Mounting Type | DIN rail, 35 mm | Quick and secure installation in control cabinets |
Housing Material | Aluminum/galvanized steel | Durable, vibration-resistant construction |
Operating Temperature | -25 °C to +70 °C (with derating above 60 °C) | Reliable performance in harsh environments |
Approvals | UL, cUL, DNV, NK, EAC, RINA | Meets international safety and quality standards |
Download QUINT-ORING/24DC/2X40/1X80 (2902879) Datasheet
Commercial Attribute | Details |
---|---|
GTIN (EAN) | 4046356698276 |
Customs Tariff Number | 85371091 |
Weight (Excl. Packaging) | 860 g |
Weight (Incl. Packaging) | 1,200 g |
Country of Origin | India |
In modern car manufacturing, production runs nonstop with robotic systems and automated conveyors. Any sudden power loss can bring the line to a halt, causing severe financial impact. By installing the QUINT-ORING/24DC/2X40/1X80 redundancy module, two power supplies can share the load equally, ensuring longer service life. If one unit fails, the other immediately maintains operation. The built-in monitoring features provide instant fault alerts, allowing technicians to address issues quickly without interrupting production. This guarantees stable power delivery to assembly robots, welding stations, and control systems, keeping manufacturing flow efficient and dependable.
Food and beverage facilities must carefully manage downtime since every stop requires rigorous cleaning and sanitization before restarting. A sudden power interruption could waste valuable ingredients and extend downtime. With the redundancy module, plants can create a secure N+1 setup where one supply continues operation while another is serviced or replaced. Auto Current Balancing ensures both units are used evenly, reducing the need for frequent replacements. The module’s diagnostic monitoring highlights early signs of imbalance or failure, enabling planned interventions during scheduled maintenance windows. This keeps production lines stable while ensuring compliance with hygiene and safety standards.
Traffic infrastructure such as tunnels, highways, and control rooms depends on uninterrupted power for lighting, sensors, and ventilation. Any disruption could compromise driver safety and traffic flow. Using the QUINT-ORING/24DC/2X40/1X80, operators can connect two independent power sources, ensuring that if one fails, the system instantly switches to the other without affecting service. The redundancy monitoring provides a clear indication of system status, allowing rapid troubleshooting. Its selective fuse breaking capability adds another layer of safety by protecting downstream circuits. This makes it a trusted choice for critical transportation infrastructure where reliability is non-negotiable.
In oil and gas refineries, control panels power essential instruments like programmable logic controllers, actuators, and safety interlocks. A single supply failure could lead to unplanned shutdowns, safety risks, and costly downtime. By integrating the QUINT-ORING/24DC/2X40/1X80, engineers achieve seamless redundancy where one supply compensates instantly for the other. Auto Current Balancing reduces thermal load on individual supplies, extending their operating life in harsh conditions. Continuous system monitoring ensures problems are detected early, enabling timely maintenance before failure occurs. The result is uninterrupted operation of sensitive processes where safety, compliance, and productivity are critical priorities.
Category | Model Name | Part Number | Benefit |
---|---|---|---|
DIN Rail Adapter | UTA 107 | 2853983 | Universal adapter for secure DIN rail mounting of the redundancy module. |
Mounting Adapter | UWA 182/52 | 2938235 | Wall adapter for stable mounting under strong vibration conditions. |
QUINT Power Supply | QUINT-PS/24DC/40 | 2866783 | High-performance 24 V DC, 40 A power supply for redundancy configurations. |
QUINT-PS/24DC/20 | 2866750 | 24 V DC, 20 A power supply—ideal for pairing in smaller redundant systems. | |
QUINT Diode Module | QUINT-DIODE/24DC/40 | 2861624 | Ensures decoupling of power supplies in simpler redundancy setups. |
QUINT Monitoring Relay | QUINT-RELAY/24DC | 2904920 | Provides additional monitoring and signaling for redundancy system health. |
For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.