$ 109.02
Compact Phoenix Contact MINI MCR-BL-I-2I ensures accurate 4–20 mA signal duplication with 4-way isolation for reliable industrial automation.
The Phoenix Contact MINI MCR-BL-I-2I Signal Duplicator (2810829) provides secure duplication and isolation of analog current signals in automation systems. Accepting a 4–20 mA input, it delivers two identical outputs with high accuracy, ensuring smooth integration into control and monitoring equipment. Its ultra-slim 6.2 mm housing saves valuable panel space while maintaining durability. Engineered for industrial environments, it minimizes the risk of interference and ensures stable operation. As part of Phoenix Contact’s essential series, this device combines reliability and affordability, making it a trusted choice for professionals who need dependable signal processing in compact installations.
The MINI MCR-BL-I-2I enhances process reliability by eliminating issues such as ground loops and noise interference, ensuring signals remain accurate and consistent. With fast response characteristics and a transmission error of less than 0.2%, it is well-suited for demanding applications where precision is critical. Its low power consumption, efficient design, and robust isolation up to 1.5 kV make it safe for use in sensitive systems. Designed for quick DIN rail installation, it streamlines setup while delivering long-term operational stability. Whether used to duplicate sensor outputs, interface with PLCs, or distribute signals across multiple devices, it guarantees clarity and continuity in signal transmission.
The MINI MCR-BL-I-2I is the ideal choice when you need reliable duplication of analog signals without compromising accuracy or safety. Its compact design saves space in crowded control cabinets, while advanced isolation prevents interference between devices. Built with precision and efficiency in mind, it ensures stable performance for process automation, monitoring, and instrumentation, making it a trusted solution for engineers demanding both dependability and cost-effectiveness.
This signal duplicator solves the common challenge of splitting one analog current signal into two stable, interference-free outputs. In complex automation setups, direct signal sharing often introduces ground loops, noise, and measurement errors. The MINI MCR-BL-I-2I eliminates these issues through robust 4-way isolation, ensuring each output is accurate and safe. By protecting sensitive equipment and preserving signal integrity, it supports smooth system integration and long-term operational reliability.
Feature | Details | Benefit |
---|---|---|
Input Signal | 4–20 mA | Compatible with standard industrial sensors |
Output Signal | 2 × 4–20 mA | Enables safe signal duplication for multiple devices |
Electrical Isolation | 4-way isolation | Protects against ground loops and interference |
Transmission Error | ≤0.2% (typical <0.1%) | Guarantees precise and stable measurements |
Step Response | 500 ms | Reliable for process control with moderate signal changes |
Nominal Supply Voltage | 24 V DC (19.2–30 V DC range) | Flexible power compatibility in industrial systems |
Power Consumption | <600 mW | Low energy use reduces operating costs |
Load Resistance | ≤250 Ω at 20 mA | Ensures consistent signal quality across outputs |
Housing Width | 6.2 mm | Space-saving design for dense DIN rail mounting |
Dimensions (H × D) | 93.1 × 102.5 mm | Fits compact control cabinet layouts |
Ambient Temperature | –10 °C … +60 °C | Suitable for a wide range of industrial environments |
Protection Rating | IP20 | Ensures safe operation in control cabinets |
Approvals | CE, UKCA, EMC compliant | Meets international safety and quality standards |
Protective Circuit | Transient protection | Safeguards against voltage spikes and surges |
Mounting | DIN rail, any position | Simplifies installation in different cabinet layouts |
Download MINI MCR-BL-I-2I 2810829 Datasheet
Attribute | Details |
---|---|
GTIN Number | 4046356672573 |
Traffic Number | DKA131 |
Weight | 63 g (without packaging) |
Country of Origin | Germany (DE) |
In process plants, a single sensor often needs to communicate with both a main controller and a separate monitoring unit. Directly connecting both devices can cause noise or uneven readings. The MINI MCR-BL-I-2I solves this by duplicating one 4–20 mA input into two identical outputs, each electrically isolated. This ensures the PLC and local display both receive the same stable measurement. By preventing cross-interference, it removes the need for installing extra sensors, reducing wiring complexity and maintenance costs while keeping measurements consistent across different control points.
Gas detectors are critical in hazardous areas, and their signals must reach safety systems as well as auxiliary alarms. Directly splitting the signal can compromise accuracy and potentially disturb the safety loop. With the MINI MCR-BL-I-2I, one detector output is safely duplicated into two isolated loops, keeping the integrity of the primary safety system intact. The second output can then be used for event logging or alarm activation without risk. Its isolation design and low transmission error make it a reliable safeguard in environments where compliance and quick detection are vital.
When flow meters measure liquids or gases for trade purposes, both supplier and customer often require the same measurement data. Installing two separate meters is costly and can introduce discrepancies. The MINI MCR-BL-I-2I enables one flow signal to be duplicated accurately, sending one output to process control and another to billing or verification systems. This guarantees both parties receive identical, trustworthy information. Its high precision and four-way isolation prevent drift or interference, ensuring fair and transparent measurement. This approach improves efficiency, saves installation expenses, and maintains confidence in the recorded flow values.
In large industrial facilities such as wastewater plants or power stations, sensors may be installed far from the control cabinet. Long cable runs expose signals to voltage drops, electromagnetic interference, and ground loops. By placing the MINI MCR-BL-I-2I near the sensor, the input signal is stabilized and safely duplicated into two isolated outputs. Each output maintains accuracy even when transmitted across extended wiring. Its protective design prevents noise from affecting downstream systems and ensures the control system receives consistent data. This is especially valuable in environments where real-time monitoring and reliability are critical for operations.
Product | Article Number | Description | Purpose / Benefit |
---|---|---|---|
MINI MCR DKL – Transparent Cover | 2308111 | Fold-up transparent protective cover for MINI MCR modules with option for labeling | Protects device and allows easy identification with labeling strips |
MINI MCR-DKL-LABEL – Marking Label | 2810272 | Extended labeling accessory for use with MINI MCR modules and transparent cover | Enables clear module labeling and simplified maintenance |
SZS 0.6X3.5 – Screwdriver Tool | 1205053 | Insulated screwdriver, 0.6 × 3.5 mm, suitable for MINI MCR terminals | Ensures safe and accurate wiring during installation |
MINI Analog Modules – MCR Series | Various | Other signal conditioners, converters, and isolators in the MINI MCR range | Expand functionality for isolation, conversion, and signal conditioning |
For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.