Phoenix Contact MACX MCR-UI-UI-UP-SP-NC Signal Conditioner

$ 297.16

Reliable Phoenix Contact MACX MCR-UI-UI-UP-SP-NC signal conditioner with 3-way isolation, 1600+ configurations, and SIL 2 safety for industrial automation.

Product Description

Phoenix Contact MACX MCR-UI-UI-UP-SP-NC Signal Conditioner

The Phoenix Contact MACX MCR-UI-UI-UP-SP-NC signal conditioner is designed to provide safe isolation, accurate amplification, and versatile conversion of analog signals in industrial applications. It supports a wide variety of voltage and current ranges, offering more than 1,600 configuration possibilities through front-mounted DIP switches. With a universal supply input ranging from 24 V to 230 V AC/DC and robust three-way electrical isolation, it enhances system safety and stability. Certified for use in hazardous environments and compliant with SIL 2 safety standards, it is a dependable choice for applications where signal reliability and operational security are essential.

This Phoenix Contact MACX MCR-UI-UI-UP-SP-NC isolating amplifier combines flexibility and safety for modern automation systems. It allows both active and passive output operation, enabling integration into diverse control architectures. Its compact 12.5 mm profile saves space on DIN rails, while push-in terminal connections simplify wiring and reduce installation time. Operators benefit from built-in supply voltage indicators and transient protection, ensuring quicker troubleshooting and minimal downtime. Designed for long-term durability in operating temperatures between –20 °C and +70 °C, and holding multiple international certifications, it ensures consistent performance across industries such as energy, manufacturing, and process automation.

Why Phoenix Contact MACX MCR-UI-UI-UP-SP-NC?

The Phoenix Contact MACX MCR-UI-UI-UP-SP-NC is the go-to solution for engineers who need maximum flexibility in handling analog signals. With over 1,600 configurable signal conversions, it adapts to virtually any process requirement. Its wide supply range and three-way isolation provide robust protection, while its slim design saves panel space. This model is chosen because it combines safety, efficiency, and adaptability in one compact device, making it a trusted tool in demanding automation environments.

What Problem Does It Solve?

In industrial systems, mismatched or unstable analog signals can lead to inaccurate measurements, downtime, and equipment failure. The MACX MCR-UI-UI-UP-SP-NC solves this by isolating, filtering, and converting signals reliably across different ranges. It eliminates ground loops, reduces interference, and ensures consistent data transmission between sensors and control units. By doing so, it protects sensitive equipment, improves measurement accuracy, and helps operators maintain process stability, even in hazardous or high-demand applications.

 


Key Features & Specifications – Phoenix Contact MACX MCR-UI-UI-UP-SP-NC: 2811569

Feature Details Benefit
Signal Configurations 1600+ via DIP switches High flexibility for multiple voltage and current ranges
Isolation 3-way electrical isolation, up to 2.5 kV test voltage Protects sensitive devices from interference and ground loops
Supply Voltage Range 24–230 V AC/DC (19.2–253 V) Wide power compatibility for diverse installations
Output Options Active and passive current/voltage outputs Adaptable to various control system requirements
Accuracy ≤0.1% transmission error Reliable measurement with minimal signal distortion
Limit Frequency Switchable 30 Hz / 10 kHz Adjustable for fast or noise-sensitive applications
Housing Width 12.5 mm DIN rail mount Saves valuable control cabinet space
Temperature Range –20 °C to +70 °C Stable operation in demanding environments
Safety Level SIL 2 (EN 61508) Meets functional safety standards for critical applications
Certifications CE, UL, ATEX, IECEx, DNV, CCC Approved for global industrial and hazardous area use
Connections Push-in spring cage terminals Faster wiring and reduced installation time
Status Indicator LED supply monitoring Quick diagnostics to reduce downtime

Download Phoenix Contact MACX MCR-UI-UI-UP-SP-NC 2811569 Datasheet

 


Commercial Data – Phoenix Contact MACX MCR-UI-UI-UP-SP-NC: 2811569

Commercial Data Details
GTIN Number 4046356466998
Tariff Number 85437090
Weight 150 g (net), 183 g (with packaging)
Country of Origin Germany

 


The Applications of Phoenix Contact MACX MCR-UI-UI-UP-SP-NC

1. Precision Current Monitoring in Heavy Equipment
In heavy industrial machinery such as turbines and large motors, accurate current monitoring is critical to prevent overheating and to optimize performance. Shunt resistors generate very small signals that need stable conversion before being processed by a control system. The MACX MCR-UI-UI-UP-SP-NC takes these low-level inputs, isolates them, and outputs standard signals that controllers can easily interpret. Its three-way electrical isolation shields against transients and interference from high-power circuits. By ensuring clean, reliable signals, this module reduces maintenance costs and safeguards both equipment and operators.

2. Reliable Tank Level Measurement in Process Plants
In chemical and water treatment facilities, liquid level sensors often transmit signals over long distances, where interference and voltage drops can distort readings. The MACX MCR-UI-UI-UP-SP-NC isolates and conditions these signals, delivering a stable output to control systems. With switchable frequency response, it can be tuned for steady-state monitoring or fast response when alarms are needed. This ensures accurate tank level measurement, which is vital for dosing chemicals, preventing spills, and maintaining safe operations. The device’s compact form also saves cabinet space, making it practical for large-scale installations.

3. Safe Signal Conditioning in Power Substations
Power substations must handle a variety of analog signals from current and voltage transformers that operate under extreme electrical conditions. The MACX MCR-UI-UI-UP-SP-NC is capable of handling wide input ranges and provides secure isolation between measurement and control systems. Its fast step response helps capture sudden changes, such as fault currents, allowing protective relays to act quickly. With its SIL 2 certification, the module adds an extra layer of safety assurance in environments where quick reaction time and secure data transmission are essential to prevent outages or equipment damage.

4. Structural Monitoring with Load Cells and Strain Sensors
Bridges, storage silos, and large industrial frames often use strain gauges or load cells to measure stress and load distribution. These sensors produce small millivolt signals that are highly vulnerable to electrical noise. The MACX MCR-UI-UI-UP-SP-NC amplifies and isolates these delicate signals, converting them into robust analog outputs for data acquisition systems. Its DIP switch configuration makes it easy to adjust settings on-site without additional programming tools. By ensuring stable and accurate readings, it helps engineers detect early signs of structural fatigue, improving long-term safety and reducing unplanned maintenance.

 


Related Products & Accessories – Phoenix Contact MACX MCR-UI-UI-UP-SP-NC

Category Model Name Part Number Benefit
Separating Plate MCR-DP 1430594 Maintains safe isolation distances on DIN rail when combining Ex i and non-Ex i devices
Insulating Sleeve (White) MPS-IH WH 0201663 Provides additional insulation protection for terminals
Insulating Sleeve (Red) MPS-IH RD 0201676 Color-coded insulation sleeve for safer wiring and identification
Insulating Sleeve (Blue) MPS-IH BU 0201689 Enhances safety with quick visual identification of connections
Insulating Sleeve (Yellow) MPS-IH YE 0201692 Provides reliable electrical insulation in compact spaces
Insulating Sleeve (Green) MPS-IH GN 0201702 Color marking for organized wiring and safety compliance
Insulating Sleeve (Gray) MPS-IH GY 0201728 Simplifies maintenance by clear terminal marking
Insulating Sleeve (Black) MPS-IH BK 0201731 Standard protection for general applications
Test Plug MPS-MT 0201744 Allows easy testing and troubleshooting of connected circuits
Plastic Label (White) UC-EMLP (11×9) 0819291 Customizable marking label for clear identification of modules
Plastic Label (Yellow) UC-EMLP (11×9) YE 0822602 Provides durable labeling with improved visibility
Plastic Label (Silver) UC-EMLP (11×9) SR 0828094 Metallic look for professional equipment marking
Device Marker (White) LS-EMLP (11×9) WH 0831678 Adhesive marker for quick equipment labeling
Power & Error Module MACX MCR-PTB 2865625 Enables power supply distribution and fault signaling for MACX modules
Power & Error Module (Push-in) MACX MCR-PTB-SP 2924184 Simplifies connection with push-in terminals and error signaling
Power Supply QUINT4-SYS-PS/1AC/24DC/2.5/SC 2904614 Reliable 24 V DC supply for MACX modules, with protective coating
Tool SZS 0.6×3.5 Screwdriver 1205053 Suitable for actuating terminals and general wiring
Connector Set MACX SET-TVFKC 2-POLE 1584383 Provides secure plug connection for non-Ex i MACX devices

 