Phoenix Contact MACX MCR-UI-UI-SP-NC Signal Conditioner – Configurable 3-Way Isolation

The Phoenix Contact MACX MCR-UI-UI-SP-NC (2811556) is a compact signal conditioner designed to deliver precise analog signal conversion and safe galvanic isolation. Engineered with front-accessible DIP switches, it offers more than 1600 conversion settings, allowing users to adapt both current and voltage signals for various process requirements. Measuring only 12.5 mm wide, it saves valuable space in control cabinets while still ensuring high performance. Certified up to SIL 2 safety levels, the device addresses the challenge of accurate signal transmission and reliable isolation in industrial environments where protection and compliance are essential.

This signal conditioner provides engineers with flexibility and assurance in demanding automation systems. By using three-way electrical isolation, it safeguards input, output, and power supply channels against interference and faults. A frequency limit of up to 10 kHz ensures fast response for time-sensitive tasks, while push-in connection technology reduces installation time and maintenance effort. Operators can configure both unipolar and bipolar current or voltage ranges, making the device highly versatile across measurement and control tasks. Its suitability for Zone 2 installations further enhances reliability in hazardous areas, giving users confidence in safety and compliance without compromising performance.

Why Phoenix Contact MACX MCR-UI-UI-SP-NC?

Because it combines compact design, over 1600 configurable conversions, and SIL 2 safety in a single unit. The MACX MCR-UI-UI-SP-NC brings unmatched flexibility, enabling engineers to adapt signals quickly while ensuring reliable isolation. Its space-saving housing and easy DIP switch setup make it the perfect choice for modern, efficient control cabinets.

What problem does it solve?

It eliminates the challenges of inaccurate signal transmission and electrical interference between devices. By isolating, filtering, amplifying, and converting analog signals, the MACX MCR-UI-UI-SP-NC protects sensitive equipment, reduces downtime, and ensures stable process operation—even in hazardous or noise-prone industrial environments.

 


Key Features & Specifications – Phoenix Contact MACX MCR-UI-UI-SP-NC: 2811556

Feature Details Benefit
Input Signal Range ±50 mV … ±100 V / ±1 mA … ±100 mA Wide compatibility with voltage and current signals
Output Signal Range 0–10 V / 0–20 mA (configurable) Flexible conversion for various control systems
Configuration DIP switches, >1600 settings Quick on-site adaptability without extra tools
Isolation 3-way galvanic isolation Protects equipment from interference and faults
Frequency Response 10 kHz (switchable to 30 Hz) Reliable for both fast and slow processes
Safety Integrity Level Up to SIL 2 (EN 61508) Certified safety for critical applications
Installation Zone Zone 2 / Div. 2 approved Safe operation in hazardous areas
Operating Temperature -20 °C to +70 °C Suitable for harsh industrial environments
Connections Push-in spring cage Faster wiring, reduced maintenance time
Housing Width 12.5 mm Space-saving design for compact control cabinets

Download Phoenix Contact MACX MCR-UI-UI-SP-NC 2811556 Datasheet

 

 


Commercial Information – Phoenix Contact MACX MCR-UI-UI-SP-NC: 2811556

Commercial Data Details
GTIN Number 4046356467001
Customs Tariff Number 85437090
Weight (Excluding Packing) 96 g
Weight (Including Packing) 169.5 g
Country of Origin Germany (DE)

 


The Applications

1. Reliable Measurement in High-Noise Manufacturing Plants

In heavy industrial workshops, equipment such as welding stations and large motors create constant electromagnetic interference that often distorts analog signals. By using a three-way isolating amplifier, sensitive sensor outputs remain stable and protected from ground loops or electrical noise. The configurable ranges allow the same module to adapt to multiple sensor types, ensuring smooth integration without the need for additional converters. As a result, process values like temperature, current, or voltage remain accurate, reducing downtime and minimizing costly recalibration work.

2. Flexible Signal Conversion in Process Control Networks

Process industries, such as water treatment or chemical plants, rely on sensors distributed across wide areas that often deliver signals in different formats. The MACX signal conditioner helps unify these signals into a consistent output that the PLC or DCS can easily read. Its wide configurability means one unit can cover many applications, lowering the need for varied hardware. Engineers benefit from simplified wiring and easier maintenance, especially in remote field stations, while control systems receive accurate and reliable data for stable operation.

3. Safe Monitoring in Hazardous and Explosive Zones

Oil, gas, and petrochemical facilities often place instrumentation in areas where explosive gases may be present. This signal conditioner, approved for Zone 2 installation, ensures that measurements remain dependable even in such environments. The three-way isolation prevents faults from spreading to the control system, while its compact size and push-in connections make installation straightforward. With safety certifications up to SIL 2, operators gain confidence that critical instrumentation will function reliably, protecting both equipment and personnel in high-risk areas.

4. Precision Energy Monitoring in Utility Applications

In electrical substations and power distribution centers, energy meters and transformers produce signals that must travel long distances to supervisory systems. Weak or noisy signals risk being misread if transmitted directly. By isolating and amplifying these inputs, the signal conditioner ensures precise values reach the monitoring system. Its adjustable voltage and current ranges allow connection to a variety of sensors, while the high frequency response captures rapid fluctuations. This leads to better energy accounting, early fault detection, and more efficient management of power infrastructure.

 


Related Products & Accessories – Phoenix Contact MACX MCR-UI-UI-SP-NC

Category Model / Accessory Part Number Benefit
DIN Rail Bus Connector ME 6,2 TBUS-2 1,5/5-ST-3,81 GY 2695439 Bridges supply voltage across devices, simplifies power distribution
Separating Plate MCR-DP 1430594 Maintains safe isolating distances when mounting Ex i and non-Ex i units side by side
Module Carrier TC-D37SUB-AIO16-EX-PS-UNI 2902932 Connects 16 MACX Analog Ex i conditioners to I/O cards with HART multiplexer
Module Carrier TC-D37SUB-ADIO16-EX-P-UNI 2924854 Universal termination carrier for connecting 16 MACX Analog Ex i conditioners to I/O cards
Insulating Sleeve (White) MPS-IH WH 0201663 Provides secure insulation for wiring
Insulating Sleeve (Red) MPS-IH RD 0201676 Color-coded insulation for easy circuit identification
Insulating Sleeve (Blue) MPS-IH BU 0201689 Enhances wiring safety with clear color marking
Insulating Sleeve (Yellow) MPS-IH YE 0201692 Supports system labeling with yellow insulation
Insulating Sleeve (Green) MPS-IH GN 0201702 Provides protective insulation with green marking
Insulating Sleeve (Gray) MPS-IH GY 0201728 Insulation accessory for structured wiring
Insulating Sleeve (Black) MPS-IH BK 0201731 Durable black sleeve for general use
Test Plug MPS-MT 0201744 Allows testing and signal monitoring in circuits
Plastic Label (White) UC-EMLP (11X9) 0819291 Adhesive label for clear device identification
Plastic Label (Yellow) UC-EMLP (11X9) YE 0822602 Provides durable marking with yellow visibility
Custom Label (White) UC-EMLP (11X9) CUS 0824547 Tailored customer-specific labeling
Custom Label (Yellow) UC-EMLP (11X9) YE CUS 0824548 Customer-specific adhesive labeling in yellow
Plastic Label (Silver) UC-EMLP (11X9) SR 0828094 Silver label sheet for equipment identification
Custom Label (Silver) UC-EMLP (11X9) SR CUS 0828098 Custom-printed silver device markers
Device Marker (White) LS-EMLP (11X9) WH 0831678 Adhesive marker for device labeling
Device Marker (Silver) LS-EMLP (11X9) SR 0831705 Silver adhesive device marker for clear identification
Device Marker (Yellow) LS-EMLP (11X9) YE 0831732 Yellow adhesive marker for labeling
Power & Error Module MACX MCR-PTB 2865625 Provides power supply and error message signaling
Power & Error Module (Push-in) MACX MCR-PTB-SP 2924184 Same as above with push-in connection convenience
Power Supply QUINT4-SYS-PS/1AC/24DC/2.5/SC 2904614 DIN rail power supply for stable 24 V DC output
Tool SZS 0,6X3,5 Screwdriver 1205053 Suitable tool for terminal block and module installation
Connector Set MACX SET-TVFKC 2-POLE 1584383 Plug set for MACX modules, simplifies connection setup

 


Contact Us

For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.

Select your currency