Reliable 2-channel NAMUR isolation amplifier with 3-way isolation, SIL 2 safety, and fault detection for safe signal transmission in automation systems.
The Phoenix Contact MACX MCR-SL-2NAM-T isolation amplifier is a compact two-channel device designed to safely transmit signals from NAMUR sensors and floating contacts to the control system. Featuring robust three-way electrical isolation, it shields sensitive equipment from electrical interference while supporting fast switching up to 5 kHz. Its narrow 12.5 mm housing saves valuable DIN rail space, making it suitable for modern, high-density panels. With integrated monitoring functions, selectable operating modes, and compliance with international safety standards, it offers a dependable solution for industries requiring precise and secure signal processing in hazardous or demanding environments.
The MACX MCR-SL-2NAM-T is built to improve reliability and reduce downtime in automation systems. Its error detection instantly identifies open circuits or short faults, while LED indicators give quick status feedback to maintenance teams. Engineers can configure the amplifier easily via DIP switches, ensuring flexibility for different system requirements. Certified for use in Zone 2 hazardous areas, it guarantees safe performance in chemical processing, manufacturing plants, and maritime applications. By combining durability, simplified troubleshooting, and safety compliance, the amplifier helps operators cut costs, extend equipment life, and achieve higher operational efficiency in critical control and monitoring tasks.
The MACX MCR-SL-2NAM-T stands out because it delivers safe signal isolation with intelligent monitoring, all in an ultra-slim housing. It ensures reliable transmission of sensor signals even in challenging industrial zones, while saving panel space and simplifying integration. With flexible operation modes, clear LED diagnostics, and SIL 2 safety certification, it’s a trusted choice for engineers who value precision, safety, and long-term performance.
In industrial environments, uncontrolled interference, wiring errors, and hazardous conditions often disrupt signal integrity. The MACX MCR-SL-2NAM-T solves this by providing three-way isolation, built-in line fault detection, and fast response switching. It transforms unreliable field signals into dependable outputs, shielding control systems from damage. This reduces downtime, prevents costly failures, and ensures continuous, safe monitoring in process automation, energy systems, and shipboard applications.
Feature | Details | Benefit |
---|---|---|
Number of Channels | 2 | Enables dual-sensor signal transmission |
Electrical Isolation | 3-way isolation, 2.5 kV test voltage | Protects control systems from interference and surges |
Input Compatibility | NAMUR sensors, floating contacts, resistance circuits | Flexible connection options for process automation |
Switching Frequency | Up to 5 kHz | Suitable for fast signal transmission and dynamic applications |
Line Fault Detection (LFD) | Configurable via DIP switch | Early detection of open or short circuits prevents downtime |
Output Type | Passive transistor outputs | Reliable switching with low power consumption |
Supply Voltage | 24 V DC (19.2 … 30 V range) | Wide supply range for stable operation |
Operating Temperature | -40 °C to +60 °C | Suitable for harsh environments |
Safety Certification | SIL 2 (IEC 61508), ATEX, IECEx, UL, DNV GL | Certified for global use in hazardous and safety-critical areas |
Housing Width | 12.5 mm DIN rail mount | Compact design saves valuable panel space |
Status Indicators | LEDs for supply, switching state, and errors | Clear diagnostics for faster maintenance |
Download MACX MCR-SL-2NAM-T 2865036 Datasheet
Commercial Data | Details |
---|---|
GTIN Number | 4046356491969 |
Tariff Number | 85365019 |
Weight | 143 g (net), 180 g (with pack) |
Country of Origin | Germany (DE) |
In oil and gas facilities, valve positions must be monitored continuously to ensure safe operation of pipelines and storage tanks. Proximity sensors with NAMUR outputs are often mounted directly on valve stems to provide open or closed feedback. The MACX MCR-SL-2NAM-T safely transmits these weak signals to the control room, even across hazardous zones. Its three-way isolation prevents interference, while SIL 2 certification ensures reliable performance in safety shutdown systems. Built-in fault detection instantly highlights wiring failures, reducing risks of false valve status reports and helping operators maintain safe and uninterrupted flow control.
Large manufacturing plants rely on long conveyor systems where downtime can halt production. NAMUR sensors detect belt movement, blockages, or breaks, but the signals must remain clean and reliable under dust and vibration. The MACX MCR-SL-2NAM-T ensures interference-free transmission of these signals into the control system, isolating the fragile sensor circuits from electrical noise. Its slim DIN-rail housing saves valuable space in control cabinets. Maintenance teams benefit from the amplifier’s LED indicators, which quickly show operational status or faults, reducing troubleshooting time and ensuring production lines stay efficient and protected.
In wastewater treatment facilities, tank levels are monitored with NAMUR-based level switches to prevent overflow or pump dry-running. These sensors are exposed to corrosive and damp environments, making signal integrity critical. The MACX MCR-SL-2NAM-T isolates and conditions these signals, ensuring dependable alarms reach the control system. Fault detection warns of broken or shorted wiring before a process disruption occurs. Its SIL 2 compliance provides added assurance in safety-critical zones, while flexible configuration allows engineers to set alarms as normally open or normally closed depending on system logic. This improves operational reliability in demanding plant conditions.
Chemical and process plants often operate pumps, mixers, or agitators that need precise monitoring. NAMUR sensors can detect rotation or guard door positions, but harsh conditions require robust signal handling. The MACX MCR-SL-2NAM-T transmits these signals with full electrical isolation, protecting the control system from surges and interference. Its fast switching capability ensures that safety shutdowns occur immediately when abnormal conditions are detected. Diagnostic LEDs provide instant visual status, helping technicians identify problems quickly. This combination of safety, speed, and reliability reduces the risk of mechanical damage, chemical leaks, or operator injury.
Category | Model Name | Part Number | Description |
---|---|---|---|
DIN Rail Bus Connector | ME 6,2 TBUS-2 1,5/5-ST-3,81 GY | 2695439 | 5-position connector for bridging supply voltage on DIN rail. |
Power Rail Adapter | ME 6,2 TBUS-PR-ADAPTER | 1136500 | Adapter enabling MACX modules to connect to universal power rails. |
Separating Plate | MCR-DP | 1430594 | Partition plate for safe spacing between Ex i and non-Ex i devices. |
Module Carrier | TC-2D37SUB-ADIO32-2EX-P-UNI | 2904684 | Termination carrier for connecting multiple MACX signal conditioners to I/O cards. |
Cover Accessory | EA-MSTB 2,5/5 | 1831016 | Cover for screw shafts of connectors, adjustable to positions. |
Insulating Sleeves | MPS-IH WH (White) | 0201663 | Insulating sleeve for wiring protection and identification. |
MPS-IH RD (Red) | 0201676 | Insulating sleeve, red color. | |
MPS-IH BU (Blue) | 0201689 | Insulating sleeve, blue color. | |
MPS-IH YE (Yellow) | 0201692 | Insulating sleeve, yellow color. | |
MPS-IH GN (Green) | 0201702 | Insulating sleeve, green color. | |
MPS-IH GY (Gray) | 0201728 | Insulating sleeve, gray color. | |
MPS-IH BK (Black) | 0201731 | Insulating sleeve, black color. | |
Test Plug | MPS-MT | 0201744 | Test plug for signal measurement with solder connection. |
Device Markers | LS-EMLP WH (White) | 0831678 | Adhesive device marker, unmarked, for equipment labeling. |
LS-EMLP SR (Silver) | 0831705 | Device marker, silver sheet for clear labeling. | |
LS-EMLP YE (Yellow) | 0831732 | Device marker, yellow sheet for equipment marking. | |
Plastic Labels | UC-EMLP / US-EMLP Series | Multiple (0822602, 0824547, 0824548, 0828094, 0828098, 0828789, 0828871, 0828872) | Plastic labeling sheets, customizable for identification. |
Power & Error Module | MACX MCR-PTB | 2865625 | Power and fault signaling module with screw connection. |
MACX MCR-PTB-SP | 2924184 | Power and fault signaling module with push-in connection. | |
Power Supply Unit | QUINT4-SYS-PS/1AC/24DC/2.5/SC | 2904614 | 24 V DC power supply unit, DIN rail mounting. |
End Covers | D-UKK 3/5 (Gray) | 2770024 | Gray end cover for terminal block assemblies. |
D-UKK 3/5 BU (Blue) | 2770105 | Blue end cover for terminal block assemblies. | |
Terminal Block | UKK 5-2R/NAMUR | 2941662 | Screw connection terminal block for NAMUR circuits. |
Tool | SZS 0,6X3,5 | 1205053 | Screwdriver/actuation tool for terminal blocks. |
Resistor Networks | FA MCR-FMR Series | 1642714, 1642715, 1642716, 1642820 | Networks for monitoring floating contacts and proximity switches. |
For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.