$ 215.74
Enhance safety and reliability with Phoenix Contact MACX MCR-SL-2NAM-RO-SP isolating switch amplifier, featuring SIL 2 and advanced line fault detection.
The Phoenix Contact MACX MCR-SL-2NAM-RO-SP isolating switch amplifier is a compact, 2-channel solution designed to process signals from NAMUR proximity sensors and switches. It reliably converts these signals into relay outputs while maintaining 3-way electrical isolation for safe system integration. Built for safety-critical tasks, it meets SIL 2 functional safety requirements, helping engineers achieve dependable signal transfer in industrial automation. With features such as line fault detection, LED status indication, and suitability for Zone 2 installation, this device addresses the common challenge of ensuring stable and interference-free communication between field devices and control systems.
The MACX MCR-SL-2NAM-RO-SP isolating switch amplifier delivers clear advantages in everyday industrial use. It minimizes downtime through quick fault identification, thanks to its built-in monitoring of cable breaks and short circuits. Flexible configuration allows it to adapt to different operating conditions, while push-in connections make wiring straightforward and efficient. Its slim DIN rail design saves valuable panel space, and the robust build ensures stable performance even under demanding conditions. Recognized by international safety approvals, it can be confidently deployed in industries such as chemical processing, oil and gas, and power generation, where accurate and isolated signal transmission is vital for smooth and safe operations.
The MACX MCR-SL-2NAM-RO-SP stands out as a precision-engineered isolating switch amplifier that merges safety, reliability, and flexibility. Its dual-channel design, SIL 2 compliance, and compact housing make it an ideal choice for industries demanding both functional safety and space efficiency. With seamless integration and rapid fault indication, it transforms complex sensor data into dependable relay outputs.
In industrial environments, inaccurate or unstable sensor signals can lead to costly downtime and safety risks. The MACX MCR-SL-2NAM-RO-SP eliminates this challenge by providing 3-way electrical isolation, robust line fault detection, and universal compatibility with NAMUR sensors. It ensures that even in harsh or hazardous zones, signals remain clear, reliable, and safe for process control systems.
Feature | Details | Benefit |
---|---|---|
Channels | 2-channel NAMUR input | Operates multiple sensors with one device |
Isolation | 3-way electrical isolation | Prevents interference and ensures signal integrity |
Functional Safety | SIL 2 certified (EN 61508) | Supports use in safety-related systems |
Line Fault Detection | Active/Deactive with LED indication | Rapid troubleshooting reduces downtime |
Outputs | Relay, 1 N/O contact per channel | Provides reliable switching for control integration |
Supply Voltage | 24 V DC (19.2–30 V DC range) | Standardized supply for easy integration |
Switching Capacity | Up to 250 V AC, 2 A | Handles industrial-grade loads with reliability |
Indicators | Green (power), Yellow (switching), Red (fault) | Visual feedback for quick status checks |
Mounting | DIN rail, 12.5 mm width | Compact installation saves cabinet space |
Approvals | ATEX, IECEx, UL, CE, DNV | Certified for hazardous and marine environments |
Operating Temp. | -40 °C to +60 °C | Reliable operation in harsh industrial conditions |
Download Phoenix Contact MACX MCR-SL-2NAM-RO-SP 2924294 Datasheet
Commercial Data | Details |
---|---|
GTIN Number | 4046356492096 |
Tariff Number | 85365019 |
Weight | 140 g (net), 179 g (with packaging) |
Country of Origin | Germany (DE) |
In petrochemical operations, pumps are critical assets that often run in explosive or hazardous areas. NAMUR proximity sensors mounted on pump shafts provide status signals that are routed through the isolating switch amplifier. The amplifier strengthens these weak signals, applies 3-way isolation, and instantly highlights faults such as cable breaks or short circuits. This ensures reliable condition monitoring, reduces false trips, and helps operators prevent costly downtime. By maintaining stable communication between field devices and control systems, plant safety and efficiency are greatly improved.
Industrial plants rely on precise valve control to regulate flow and pressure in pipelines. Sensors positioned on valves generate low-level NAMUR signals that need reliable transmission to safety systems. By using the isolating switch amplifier, these signals are safely converted into robust relay outputs, ready for integration into control logic. Its SIL 2 certification and built-in error detection guarantee that misaligned valves or wiring faults are promptly recognized. This capability improves operational reliability, avoids leaks or process disturbances, and enhances overall plant safety compliance.
In wastewater treatment facilities, level monitoring devices are often exposed to harsh and wet environments where sensor signals can easily degrade. The isolating switch amplifier ensures these weak NAMUR outputs are reliably translated into control room alarms. Its fault detection and LED indication simplify maintenance, allowing staff to identify issues without dismantling equipment. With its robust build and safe isolation, the amplifier ensures critical level alarms are not missed, preventing overflow, equipment damage, and environmental hazards.
In modern production lines, proximity sensors on conveyors and machines detect the presence, position, or speed of components. Because NAMUR outputs are inherently low power, they require amplification and reliable isolation before being processed by a PLC. The isolating switch amplifier converts these signals into strong relay outputs, ensuring dependable system response. Its selectable operating modes provide flexibility for different automation tasks, while its compact DIN rail design saves valuable cabinet space. This combination helps reduce downtime, improve accuracy, and keep manufacturing systems running smoothly.
Category | Model Name | Part Number | Benefits |
---|---|---|---|
DIN Rail Bus Connector | ME 6,2 TBUS-2 1,5/5-ST-3,81 GY | 2695439 | Bridges supply voltage across modules, easy DIN rail installation |
DIN Rail Adapter | ME 6,2 TBUS-PR-ADAPTER | 1136500 | Enables MACX modules to connect with universal power rail systems |
Partition Plate | MCR-DP | 1430594 | Maintains safe isolating distance between Ex i and non-Ex i devices |
Module Carrier | TC-2D37SUB-ADIO32-2EX-P-UNI | 2904684 | Connects up to 16 two-channel MACX modules to I/O cards |
Insulating Sleeves | MPS-IH (WH/RD/BU/YE/GN/GY/BK) | 0201663 – 0201731 | Provides safe insulation, available in multiple colors for coding |
Test Plug | MPS-MT | 0201744 | Allows simple connection checks during commissioning or maintenance |
Device Markers | UC-EMLP / US-EMLP / LS-EMLP (various colors) | 0819291 – 0831732 | Labeling solutions for clear module identification |
Power & Error Modules | MACX MCR-PTB / MACX MCR-PTB-SP | 2865625 / 2924184 | Provides collective power supply and central fault signaling |
Power Supply | QUINT4-SYS-PS/1AC/24DC/2.5/SC | 2904614 | Reliable 24 V DC supply with protective coating |
End Covers | D-UKK 3/5 / D-UKK 3/5 BU | 2770024 / 2770105 | Covers open terminals for safety and insulation |
Terminal Block | UKK 5-2R/NAMUR | 2941662 | Screw terminal block designed for NAMUR applications |
Tools | SZS 0,6X3,5 Screwdriver | 1205053 | Insulated tool for terminal actuation and adjustments |
Connector Set | MACX SET-TVFKC 2-POLE | 1584383 | Plug set for secure connection of MACX modules |
Resistor Networks | FA MCR-FMR Series | 1642714 – 1642820 | Monitors floating contacts and supports NAMUR sensor signal conditioning |
For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.