Features

  • The thin and light body of 85 x 22.5 mm (D x W) can be mounted in a low-profile control panel and mounted on aluminum rails.
  • Easily replace removable terminal blocks to simplify maintenance.
  • 50 ms high-speed sampling for high-speed heating applications.
  • The PLC can be easily connected using the programless communication function.
  • The model is equipped with the full basic functions of 2 auxiliary outputs and 1 event input.
  • The white PV display (height: 8.5 mm) is easy to read when setting and checking alarms and setting in the control panel.

 

Lineup

Screw terminal type E5DC-800 type
22.5 × 96 mm

Control the output Auxiliary output communication The heater is disconnected Event input Supply voltage Model *2
Relay output ── RS-485 ── ── 100~240 VAC E5DC-RX0ASM-815
E5DC-RX0AUM-815
Voltage output E5DC-QX0ASM-815
E5DC-QX0AUM-815
Linear current output*1 E5DC-CX0ASM-815
E5DC-CX0AUM-815
Relay output 24 VAC/VDC E5DC-RX0DSM-815
E5DC-RX0DUM-815
Voltage output E5DC-QX0DSM-815
E5DC-QX0DUM-815
Linear current output*1 E5DC-CX0DSM-815
E5DC-CX0DUM-815
Relay output 2 pcs ── 100~240 VAC E5DC-RX2ASM-800
E5DC-RX2AUM-800
Voltage output E5DC-QX2ASM-800
E5DC-QX2AUM-800
Linear current output*1 E5DC-CX2ASM-800
E5DC-CX2AUM-800
Relay output 24 VAC/VDC E5DC-RX2DSM-800
E5DC-RX2DUM-800
Voltage output E5DC-QX2DSM-800
E5DC-QX2DUM-800
Linear current output*1 E5DC-CX2DSM-800
E5DC-CX2DUM-800
Relay output RS-485 Single-phase heater detection function 100~240 VAC E5DC-RX2ASM-802
E5DC-RX2AUM-802
Voltage output E5DC-QX2ASM-802
E5DC-QX2AUM-802
Linear current output*1 ── E5DC-CX2ASM-815
E5DC-CX2AUM-815
Relay output Single-phase heater detection function 24 VAC/VDC E5DC-RX2DSM-802
E5DC-RX2DUM-802
Voltage output E5DC-QX2DSM-802
E5DC-QX2DUM-802
Linear current output*1 ── E5DC-CX2DSM-815
E5DC-CX2DUM-815
Relay output ── Single-phase heater detection function 1 pcs 100~240 VAC E5DC-RX2ASM-817
E5DC-RX2AUM-817
Voltage output E5DC-QX2ASM-817
E5DC-QX2AUM-817
Linear current output*1 ── E5DC-CX2ASM-816
E5DC-CX2AUM-816
Relay output Single-phase heater detection function 24 VAC/VDC E5DC-RX2DSM-817
E5DC-RX2DUM-817
Voltage output E5DC-QX2DSM-817
E5DC-QX2DUM-817
Linear current output*1 ── E5DC-CX2DSM-816
E5DC-CX2DUM-816

*1. The control output can be used as a simple transfer output for digital temperature controllers manufactured in July 2014 or later.
*7. If you select two auxiliary outputs, you can only select the optional product 2.
If the control output is a relay output or a voltage output and two auxiliary outputs are selected, only optional products 000 and 002 can be selected.
If the control output is a relay output or a voltage output and two auxiliary outputs are selected, the optional product 017 cannot be selected.
If the control output is a linear current output and two auxiliary outputs are selected, only the optional product 015 can be selected.

Heating/cooling control

Use heating/cooling control (1) Control output distribution
<> auxiliary output can be used as a cooling control
output.
(<>) Control
If PID control is used, PID control can be set separately for heating and cooling.
Allows you to set the control system to have different heating and cooling reaction characteristics.