$ 744.75
Optimize quality control with the SICK OD1-B035H15U25 (6050506) OD Mini sensor. Precise 20–50mm laser measurement, stainless steel housing, and 0–10V analog output.
The SICK OD1-B035H15U25 (Part No. 6050506) is a high-precision laser displacement sensor from the renowned OD Mini series, designed for demanding industrial environments where space is at a premium. Encased in a rugged, corrosion-resistant stainless steel housing, this sensor utilizes advanced CMOS receiver technology to provide stable and accurate distance measurements regardless of the target’s color or surface texture.
With a measuring range of 20 mm to 50 mm, the OD Mini Prime offers exceptional linearity of ± 30 µm and a repeatability of 6 µm, ensuring consistent performance in high-stakes quality control tasks. Its integrated controller and user-friendly 4-digit display allow for stand-alone operation without the need for an external evaluation unit. The device features a versatile 0–10 V analog output for continuous distance monitoring and a selectable PNP/NPN digital output for limit detection. Its Laser Class 1 rating ensures operator safety while providing a highly visible light spot for easy alignment. Whether used for checking tolerances, positioning robot arms, or monitoring material thickness, the 6050506 delivers a cost-effective, precise, and durable solution for modern factory automation.
| Supply voltage Vs | DC 12 V (–5 %) … DC 24 V (+10 %) |
| Power consumption | ≤ 1.92 W 1) |
| Warm-up time | ≤ 5 min |
| Housing material | Stainless steel |
| Window material | Plastic (PPSU) |
| Connection type | Cable with male connector, M12, 5-pin, 30 cm |
| Indication | 4-digit 7-segment display (plus 4 LEDs for status display) |
| Control elements | 4 buttons |
| Weight | 70 g |
| Dimensions (W x H x D) | 17.8 mm x 44.4 mm x 31 mm |
| Enclosure rating | IP67 |
| Protection class | III |
| Measuring range | 20 mm … 50 mm |
| Target | Natural objects |
| Repeatability | 6 µm 1) 2) |
| Linearity | ± 30 µm 3) |
| Response time | ≥ 2 ms 4) |
| Measuring frequency | ≤ 2 kHz |
| Output time | ≥ 0.5 ms |
| Light source | Laser, red visible red light |
| Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) 5) |
| Typ. light spot size (distance) | 800 µm x 450 µm (35 mm) |
| Additional function | Averaging 1 … 512x, automatic or manual sensitivity adjustment, Analog outputs can be taught in, digital outputs can be taught in, invertable digital output, switching mode: window (Wnd), switching mode: distance to object (DtO), switiching mode: object between sensor and background (ObSB), multifunctional input: laser-off / external teach-in / trigger |
|
|||||||||||
|
|||||||||||
| Multifunctional input (MF) | 1 x 1) | ||||||||||
| Ambient temperature, operation | –10 °C … +50 °C |
| Ambient temperature, storage | –20 °C … +60 °C |
| Min. rel. humidity (not condensing) | 35 % |
| Max. rel. humidity (not condensing) | 95 % |
| Temperature drift | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
| Typ. Ambient light immunity | Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx |
| Vibration resistance | 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
| Shock resistance | 50 G (x, y, z axis 3 times each) |