$ 1,663.48
Optimize your precision with the SICK OD1-B035C15I25 (6050524). A compact OD Mini displacement sensor featuring 20–50mm range, CMOS technology, and IP67 protection.
The SICK OD1-B035C15I25, part number 6050524, is a high-performance displacement measurement sensor from the renowned OD Mini product family. Engineered for precision in compact spaces, this sensor utilizes advanced CMOS receiver technology to deliver highly accurate distance measurements ranging from 20 mm to 50 mm. Its integrated amplifier unit allows for stand-alone operation, making it an efficient and cost-effective solution for various industrial environments.
Constructed with a rugged aluminum housing and rated at IP67, the OD1-B035C15I25 is designed to withstand harsh operating conditions while maintaining a lightweight profile of only 40g. The device features an intuitive 4-digit 7-segment display with four status LEDs, simplifying the commissioning and monitoring process. Whether measuring on dark, bright, or varying surfaces, the sensor ensures high machine throughput and reliability. Its versatile interface, including a selectable PNP/NPN digital output and a 4-20mA analog output, provides seamless integration into existing control systems and industrial networks.
| Supply voltage Vs | DC 12 V (–5 %) … DC 24 V (+10 %) |
| Power consumption | ≤ 1.92 W 1) |
| Warm-up time | ≤ 5 min |
| Housing material | Metal (Aluminum) |
| Window material | Plastic (PPSU) |
| Connection type | Cable with male connector, M12, 5-pin, 30 cm |
| Indication | 4-digit 7-segment display (plus 4 LEDs for status display) |
| Control elements | 4 buttons |
| Weight | 40 g |
| Dimensions (W x H x D) | 17.8 mm x 44.4 mm x 31 mm |
| Enclosure rating | IP67 |
| Protection class | III |
| Measuring range | 20 mm … 50 mm |
| Target | Natural objects |
| Repeatability | 6 µm 1) 2) |
| Linearity | ± 30 µm 3) |
| Response time | ≥ 2 ms 4) |
| Measuring frequency | ≤ 2 kHz |
| Output time | ≥ 0.5 ms |
| Light source | Laser, red visible red light |
| Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) 5) |
| Typ. light spot size (distance) | 800 µm x 450 µm (35 mm) |
| Additional function | Averaging 1 … 512x, automatic or manual sensitivity adjustment, Analog outputs can be taught in, digital outputs can be taught in, invertable digital output, switching mode: window (Wnd), switching mode: distance to object (DtO), switiching mode: object between sensor and background (ObSB), multifunctional input: laser-off / external teach-in / trigger |
|
|||||||||||
|
|||||||||||
| Multifunctional input (MF) | 1 x 1) | ||||||||||
| Ambient temperature, operation | –10 °C … +50 °C |
| Ambient temperature, storage | –20 °C … +60 °C |
| Min. rel. humidity (not condensing) | 35 % |
| Max. rel. humidity (not condensing) | 95 % |
| Temperature drift | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
| Typ. Ambient light immunity | Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx |
| Vibration resistance | 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
| Shock resistance | 50 G (x, y, z axis 3 times each) |