NX-PD / PF / PC / TBX – NX-series – Omron System Unit

$ 42.46$ 90.42

SKU N/A Category

SYSTEM Units

Product name Specifications Model
Additional NX Unit
Power Supply Unit

Power supply voltage: 24 VDC (20.4 to 28.8 VDC)
NX Bus power supply capacity: 10 W max.
NX-PD1000
Additional I/O
Power Supply Unit

Power supply voltage: 5 to 24 VDC (4.5 to 28.8 VDC)
I/O power feed maximum current: 4 A
NX-PF0630
Power supply voltage: 5 to 24 VDC (4.5 to 28.8 VDC)
I/O power feed maximum current: 10 A
NX-PF0730
I/O Power Supply
Connection Unit

Number of I/O power terminals: IOG: 16 terminals
Current capacity of I/O power terminal: 4 A/terminal max.
NX-PC0010
Number of I/O power terminals: IOV: 16 terminals
Current capacity of I/O power terminal: 4 A/terminal max.
NX-PC0020
Number of I/O power terminals: IOV: 8 terminals, IOG: 8 terminals
Current capacity of I/O power terminal: 4 A/terminal max
NX-PC0030
Shield Connection
Unit

Number of shield terminals: 14 terminals
(The lower two terminals are functional ground terminals.)
NX-TBX01

 

 

General Specification

Item Specification
Enclosure Mounted in a panel
Grounding method Ground to 100 Ω or less
Operating
environment
Ambient operating
temperature
0 to 55°C
Ambient operating
humidity
10% to 95% (with no condensation or icing)
Atmosphere Must be free from corrosive gases.
Ambient storage
temperature
-25 to 70°C (with no condensation or icing)
Altitude 2,000 m max.
Pollution degree 2 or less: Meets IEC 61010-2-201.
Noise immunity 2 kV on power supply line (Conforms to IEC61000-4-4.)
Overvoltage category Category II: Meets IEC 61010-2-201.
EMC immunity level Zone B
Vibration resistance Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2,
100 min each in X, Y, and Z directions
(10 sweeps of 10 min each = 100 min total)
Shock resistance Conforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and Z
directions
Applicable standards * cULus: Listed (UL508), ANSI/ISA 12.12.01, EU: EN 61131-2, C-Tick or RCM,
KC Registration, NK, and LR

 

* Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each model.

 

Specification

Additional NX Unit Power Supply Unit NX-PD1000

Unit name Additional NX Unit Power Supply Unit
Model NX-PD1000
External connection
terminals
Screwless push-in terminal block (8 terminals)
Power supply voltage 24 VDC (20.4 to 28.8 VDC)
NX Bus power supply
capacity
10 W max. (Refer to Installation orientation and restrictions for details.)
NX Unit power supply
efficiency
70%
Unwired terminal
current capacity
4 A max. (Including the current of through-wiring)
Dimensions 12 (W) × 100 (H) 71 × (D)
Isolation method No-isolation
Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
NX Unit power
consumption
• Connected to a CPU Unit or Communication Control Unit
0.85 W max.
• Connected to a Communications Coupler Unit
0.45 W max.
I/O current
consumption
No consumption
Weight 65g max.
Circuit layout 3193_sp_2_1
Installation orientation
and restrictions
3193_sp_2_2
Terminal connection
diagram
3193_sp_2_3

 

*1. You can use the unwired terminals of the Unit power supply terminals (UV/UG) for through-wiring of the Additional NX
Unit Power Supply Unit or the Unit power supply terminals on the EtherCAT Coupler Unit.
*2. The NC terminal is not connected to the internal circuit.

 

Additional I/O Power Supply Units NX-PF0[]30

Unit name Additional I/O Power Supply Unit
Model NX-PF0630 NX-PF0730
External connection
terminals
Screwless push-in terminal block (8 terminals)
Power supply voltage 5 to 24 VDC (4.5 to 28.8 VDC) *
I/O power supply
maximum current
4 A 10 A
Current capacity of I/O
power supply terminal
4 A max. 10 A max.
Dimensions 12 (W) × 100 (H) 71 × (D)
Isolation method No-isolation
Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
NX Unit power
consumption
• Connected to a CPU Unit or Communication Control Unit
0.85 W max.
• Connected to a Communications Coupler Unit
0.45 W max.
I/O current
consumption
10 mA max.
Weight 65 g max.
Circuit layout 3193_sp_3_1
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: No restrictions
Terminal connection
diagram
3193_sp_3_2
Overload/low voltage
detection
Not supported
Protective function Not supported.

 

* Use an output voltage that is appropriate for the I/O circuits of the NX Units and the connected external devices.

 

I/O Power Supply Connection Unit IOG terminal type NX-PC0010

Unit name I/O Power Supply Connection Unit
Model NX-PC0010
External connection
terminals
Screwless push-in terminal block (16 terminals)
Number of I/O power
supply terminals
IOG: 16 terminals
Current capacity of I/O
power supply terminal
4 A/terminal max.
Dimensions 12 (W) × 100 (H) 71 ×(D)
Isolation method No-isolation
Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
NX Unit power
consumption
• Connected to a CPU Unit or Communication Control Unit
0.85 W max.
• Connected to a Communications Coupler Unit
0.45 W max.
I/O current
consumption
No consumption
Weight 65 g max.
Circuit layout 3193_sp_4_1
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: No restrictions
Terminal connection
diagram
3193_sp_4_2

 

 

I/O Power Supply Connection Unit IOV terminal type NX-PC0020

Unit name I/O Power Supply Connection Unit
Model NX-PC0020
External connection
terminals
Screwless push-in terminal block (16 terminals)
Number of I/O power
supply terminals
IOV: 16 terminals
Current capacity of I/O
power supply terminal
4 A/terminal max.
Dimensions 12 (W) × 100 (H) 71 × (D)
Isolation method No-isolation
Isolation resistance 20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
NX Unit power
consumption
• Connected to a CPU Unit or Communication Control Unit
0.85 W max.
• Connected to a Communications Coupler Unit
0.45 W max.
I/O current
consumption
No consumption
Weight 65 g max.
Circuit layout 3193_sp_5_1
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: No restrictions
Terminal connection
diagram
3193_sp_5_2

 

I/O Power Supply Connection Unit IOV/IOG terminal type NX-PC0030

Unit name I/O Power Supply Connection Unit
Model NX-PC0030
External connection
terminals
Screwless push-in terminal block (16 terminals)
Number of I/O power
supply terminals
IOV: 8 terminals
IOG: 8 terminals
Current capacity of I/O
power supply terminal
4 A/terminal max.
Dimensions 12 (W) × 100 (H) 71 × (D)
Isolation method No-isolation
Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
NX Unit power
consumption
• Connected to a CPU Unit or Communication Control Unit
0.85 W max.
• Connected to a Communications Coupler Unit
0.45 W max.
I/O current
consumption
No consumption
Weight 65 g max.
Circuit layout 3193_sp_6_1
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: No restrictions
Terminal connection
diagram
3193_sp_6_2

 

Shield Connection Unit NX-TBX01

Unit name Shield Connection Unit
Model NX-TBX01
External connection
terminals
Screwless push-in terminal block (16 terminals)
Number of shield
terminals
14 terminals (The following two terminals are functional ground terminals.)
Dimensions 12 (W) × 100 (H) 71 × (D)
Isolation method Isolation between the SHLD functional ground terminal, and internal circuit: No-isolation
Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC)
Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max.
NX Unit power
consumption
• Connected to a CPU Unit or Communication Control Unit
0.85 W max.
• Connected to a Communications Coupler Unit
0.45 W max.
I/O current
consumption
No consumption
Weight 65 g max.
Circuit layout 3193_sp_7_1
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit or Communication Control Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: No restrictions
Terminal connection
diagram