General specifications |
Switching function |
Normally closed (NC) |
Output type |
NAMUR |
Rated operating distance |
5 mm |
Installation |
flush |
Assured operating distance |
0 … 4.05 mm |
Actual operating distance |
4.5 … 5.5 mm typ. 5 mm |
Reduction factor rAl |
0.35 |
Reduction factor rCu |
0.3 |
Reduction factor r304 |
0.74 |
Output type |
2-wire |
Nominal ratings |
Nominal voltage |
8.2 V (Ri approx. 1 kΩ) |
Switching frequency |
0 … 400 Hz |
Hysteresis |
1 … 15 typ. 5 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
yes |
Current consumption |
|
Measuring plate not detected |
min. 3 mA |
Measuring plate detected |
≤ 1 mA |
Switching state indicator |
Multihole-LED, yellow |
Functional safety related parameters |
Safety Integrity Level (SIL) |
SIL 2 |
MTTFd |
1880 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Compliance with standards and directives |
Standard conformity |
|
NAMUR |
EN 60947-5-6:2000
IEC 60947-5-6:1999 |
Electromagnetic compatibility |
NE 21:2007 |
Standards |
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012 |
Approvals and certificates |
IECEx approval |
|
Equipment protection level Ga |
IECEx PTB 11.0037X |
Equipment protection level Gb |
IECEx PTB 11.0037X |
Equipment protection level Da |
IECEx PTB 11.0037X |
Equipment protection level Mb |
IECEx PTB 11.0037X |
ATEX approval |
|
Equipment protection level Ga |
PTB 00 ATEX 2048 X |
Equipment protection level Gb |
PTB 00 ATEX 2048 X |
Equipment protection level Da |
PTB 00 ATEX 2048 X |
UL approval |
|
Ordinary Location |
E87056 |
Hazardous Location |
E501628 |
Control drawing |
116-0452 |
CCC approval |
|
Hazardous Location |
2020322315002255 |
NEPSI approval |
|
NEPSI certificate |
GYJ16.1393X |
TIIS approval |
on request |
ANZEx |
18.3018X |
KCC approval |
|
Hazardous Location |
09-AV4BO-0226 |
Marine approval |
DNVGL TAA00001A5 |
Ambient conditions |
Ambient temperature |
-25 … 100 °C (-13 … 212 °F) |
Storage temperature |
-40 … 100 °C (-40 … 212 °F) |
Mechanical specifications |
Connection type |
Connector plug |
Housing material |
Stainless steel 1.4305 / AISI 303 |
Sensing face |
PBT |
Degree of protection |
IP66 / IP67 |
Connector |
|
Threading |
M12 x 1 |
Number of pins |
4 |
General information |
Use in the hazardous area |
see instruction manuals |