NA Series – Omron Programmable Terminal

USD $ 2,555.91USD $ 4,086.81

SKU: N/A

List of Models

Product name Specifications Model *1
NA5-15W 15.4 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color),
1280 × 800 dots, Frame color: Silver
NA5-15W101S-V1
15.4 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color),
1280 × 800 dots, Frame color: Black
NA5-15W101B-V1
NA5-12W 12.1 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color),
1280 × 800 dots, Frame color: Silver
NA5-12W101S-V1
12.1 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color),
1280 × 800 dots, Frame color: Black
NA5-12W101B-V1
NA5-9W 9 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color),
800 × 480 dots, Frame color: Silver
NA5-9W001S-V1
9 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color),
800 × 480 dots, Frame color: Black
NA5-9W001B-V1
NA5-7W 7 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color),
800 × 480 dots, Frame color: Silver
NA5-7W001S-V1
7 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color),
800 × 480 dots, Frame color: Black
NA5-7W001B-V1
High-pressure
Waterproof
Attachment
This metal frame is for high-pressure waterproofing. Install it to conform
to UL Type 4X standards.
UL Type 4X is the rating for high-pressure wash-down applications with
a flow rate of 246 liter/min.
NA-15WATW01
NA-12WATW01
NA-9WATW01
NA-7WATW01

 

Performance Specifications

Display

Item Specification
NA5-15W NA5-12W NA5-9W NA5-7W
Display panel
*1
Display device TFT LCD
Screen size 15.4 inches 12.1 inches 9.0 inches 7.0 inches
Resolution 1,280 × 800 dots (horizontal × vertical) 800 × 480 dots (horizontal × vertical)
Colors 16,770,000 colors (24 bit full colors)
Effective display
area
331 × 207 mm
(horizontal ×
vertical)
261 × 163 mm
(horizontal ×
vertical)
197 × 118 mm
(horizontal ×
vertical)
152 × 91 mm
(horizontal ×
vertical)
View angles Left: 60°, Right: 60°, Top: 60°, Bottom: 60°
Backlight *2 Life 50,000 hours min. *3
Brightness
adjustment
200 levels
Type LED
Front panel
indicators *4
RUN Lit green: Normal operation Lit red: Error

 

*1. There may be some defective pixels in the display. This is not a fault as long as the numbers of defective light and
dark pixels fall within the following standard ranges.

 

Model Standard range
NA5-15W[][][][]-V1
NA5-12W[][][][]-V1
NA5-9W[][][][]-V1
NA5-7W[][][][]-V1
Number of light and dark pixels: 10 or less. (There must not be 3 consecutive light/dark pixels.)

 

*2. The backlight can be replaced at an OMRON maintenance base.
*3. This is the estimated time before brightness is reduced by half at room temperature and humidity. The life expectancy
is drastically shortened if Programmable Terminal is used at high temperatures.
*4. The brightness of the front panel indicators is also adjustable when you adjust the brightness of the backlight.

 

Operation

Item Specification
NA5-15W NA5-12W NA5-9W NA5-7W
Touch panel Method: Analog resistive membrane type
Resolution: 16,384 × 16,384
Life: 1,000,000 operations
Function keys *1 3 inputs (capacitance inputs)

 

*1. Each function key has blue indicator. The brightness of the function key indicators is also adjustable when you adjust
the brightness of the backlight.

 

Data Capacity

Item Specification
NA5-15W NA5-12W NA5-9W NA5-7W
User data capacity 256 MB

 

External Interfaces

Item Specifications (Same for all models.)
Ethernet
ports
Applications Port 1: Connecting to anything other than the Sysmac Studio, e.g., device
connections and VNC clients
Port 2: Connecting to the Sysmac Studio in addition to the applications of port 1.
Number of ports 2 ports
Compliant standards IEEE 802.3i (10BASE-T), IEEE 802.3u (100BASE-TX), and IEEE 802.3ab
(1000Base-T)
Transmission media Shielded twisted-pair (STP) cable: Category 5, 5e, or higher
Transmission distance 100 m
Connector RJ-45 8P8C modular connector
USB host
ports *1 *2
Applications USB Memory Device, keyboard, or mouse
Number of ports 2 ports
Compliant standards USB 2.0
Transmission distance 5 m max.
Connector Type-A connector
USB slave
port *1
Applications Sysmac Studio connection
Number of ports 1 port
Compliant standards USB 2.0
Transmission distance 5 m max.
Connector Type-B connector
Serial port Applications Device Connection
Number of ports 1 port
Compliant standards RS-232C
Transmission distance 15 m max.
Connector D-DUB 9-pin female connector
SD Memory
Card slot
Applications To transfer or store the project or to store log data.
Number of slots 1 slot
Compliant standards SD/SDHC

 

*1. Connection to all USB 2.0-compliant devices is not guaranteed.
*2. Use a USB memory for temporary applications such as transferring data.
Note: 1. For information on the product whose model number does not end with -V1, refer to the Programmable Terminal NA Series Datasheet (Cat. No. V413).

 

General Specifications

Item Specification
NA5-15W NA5-12W NA5-9W NA5-7W
Rated supply voltage 24 VDC
Allowable power
supply voltage range
19.2 to 28.8 VDC (24 VDC ±20%)
Allowable
momentary power
interruption time
Operation for momentary power interruption is not specified.
Power consumption 29 W max. 25 W max. 23 W max. 19 W max.
Ambient operating
temperature
0 to 50°C *1 *2
Ambient storage
temperature
-20 to +60°C *3
Ambient operating
humidity
10 to 90% *2
Must be no condensation.
Atmosphere Must be free from corrosive gases.
Pollution degree 2 or less: Meets IEC 61010-2-201.
Noise immunity 2 kV on power supply line (Conforms to IEC 61000-4-4.)
Vibration resistance
(during operation)
Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5 mm half amplitude and 8.4 to 150 Hz with 9.8 m/s2 for 100 minutes each in
X, Y, and Z directions
(Time coefficient of 10 minutes × coefficient factor of 10 = total time of 100 min.)
Shock resistance
(during operation)
Conforms to IEC 60028-2-27.
147 m/s2 3 times each in X, Y, and Z directions
Dimensions 420 × 291 × 69 mm
(W × H × D)
340 × 244 × 69 mm
(W × H × D)
290 × 190 × 69 mm
(W × H × D)
236 × 165 × 69 mm
(W × H × D)
Panel cutout
dimensions
392 +1,0 ×
268 +1,0 mm
(horizontal × vertical)
Panel thickness:
1.6 to 6.0 mm *4
310 +1,0 ×
221 +1,0 mm
(horizontal × vertical)
Panel thickness:
1.6 to 6.0 mm *4
261 +1,0 ×
166 +1,0 mm
(horizontal × vertical)
Panel thickness:
1.6 to 6.0 mm *4
197 +0.5,0 ×
141 +0.5,0 mm
(horizontal × vertical)
Panel thickness:
1.6 to 6.0 mm *4
Weight 3.2 kg max. 2.4 kg max. 1.8 kg max. 1.4 kg max.
Degree of
protection
Front-panel controls: IP65 oil-proof type, UL Type 4X (at initial state)
To reinstall the NA Unit in a panel, contact your OMRON representative for replacement of the
rubber packing.
Battery life Battery life: 5 years at 25°C
The RTC will be backed up for 5 days after the battery runs low. The RTC will be backed up by a
super capacitor for 5 minutes after removing the old battery.
(This assumes that the power is first turned ON for at least 5 minutes and then turned OFF.)
International
standards *5
UL61010-2-201/CSA C22.2 NO.61010-2-201:14 *6
EMC Directive (2004/108/EC) EN 61131-2:2007
Shipbuilding standards LR, DNV, and NK
IP65 oil-proof, UL Type 4X *7(front panel only)
UL 121201, 9th Edition/CSA C22.2 NO.213-2017
EAC IEC61131-2:2007
KC Standards KN61131-2 2018
RCM EN61000-6-4:2007+A1:2011

 

*1. The ambient operating temperature is subject to the following restrictions, depending on the mounting angle.
• The ambient operating temperature is 0° to 40°C when the mounting angle is 0° or more and less than 45° to the horizontal.
• The ambient operating temperature is 0° to 50°C when the mounting angle is 45° or more and 90° or less to the horizontal.
• The ambient operating temperature is 0° to 50°C when the mounting angle is 90° or more and 135° or less to the horizontal.

*2. Use the Programmable Terminal within the following temperature and humidity ranges.

NA Series Specifications 13

*3. Store the Programmable Terminal within the following temperature and humidity ranges.

NA Series Specifications 14

*4. When the NA-[]WATW01 High-pressure Waterproof Attachment is used, the panel thickness is between 1.6 to 4.5 mm.
*5. Check with your OMRON representative or refer to the following OMRON website for the latest information on the
applicable standards for each model: www.ia.omron.com.
*6. Use power supply Class 2 to conform to UL Standards.
*7. Use the NA-[]WATW01 High-pressure Waterproof Attachment (sold separately) to conform to UL Type 4X.
Note: 1. For information on the product whose model number does not end with -V1, refer to the Programmable Terminal NA Series Datasheet (Cat. No. V413).

Weight N/A
Model

, , , , , , ,

Related products