$ 16.72 – $ 25.52
Product number | A9N22420 | A9N22421 | A9N22422 | A9N22423 |
Product family | Multi9 | Multi9 | Multi9 | Multi9 |
Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
Product name | C65-DC | C65-DC | C65-DC | C65-DC |
Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
Short name of the product | C65N-DC | C65N-DC | C65N-DC | C65N-DC |
Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
Number of poles | 2P | 2P | 2P | 2P |
Number of protection poles | 2 | 2 | 2 | 2 |
Rated current [In] | 1 A in… Up to 40 °C | 2 A in… Up to 40 °C | 4 A in… Up to 40 °C | 6 A in… Up to 40 °C |
Network type | DC | DC | DC | DC |
Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
Trip curve | C | C | C | C |
Breaking ability | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
Supplemental Information | ||||
Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
Magnetic trip restrictions | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % |
Using Breaking Capability [ICS] | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC |
Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
Rated impulse withstand voltage [UIMP] | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 |
Width (multiple of 9mm) | 4 | 4 | 4 | 4 |
height | 84 mm | 84 mm | 84 mm | 84 mm |
width | 36 mm | 36 mm | 36 mm | 36 mm |
depth | 73.5 mm | 73.5 mm | 73.5 mm | 73.5 mm |
Product net weight | 220 g | 220 g | 220 g | 220 g |
Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² |
Tightening torque | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: |
Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
environment | ||||
Compliance with standards | GB 14048.2 | IEC 60947-2 | GB 14048.2 | IEC 60947-2 |
IEC 60947-2 | GB 14048.2 | IEC 60947-2 | GB 14048.2 | |
Product certification | CCC | CCC | CCC | CCC |
IEC CB report | IEC CB report | IEC CB report | IEC CB report | |
Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 3.509 cm | 3.513 cm | 3.522 cm | 3.6 cm |
Package 1 Width | 7.378 cm | 7.4 cm | 7.4 cm | 7.3 cm |
Package 1 Length | 8.38 cm | 8.336 cm | 8.346 cm | 8.4 cm |
Package 1 Weight | 219.7 g | 214.1 g | 213.5 g | 208 g |
Unit Type of Package 2 | BB1 | BB1 | BB1 | BB1 |
Number of Units in Package 2 | 6 | 6 | 6 | 6 |
Package 2 Height | 7.818 cm | 8.128 cm | 8.264 cm | 8.048 cm |
Package 2 Width | 8.803 cm | 8.925 cm | 9.024 cm | 8.968 cm |
Package 2 Length | 21.963 cm | 22.211 cm | 22.184 cm | 22.092 cm |
Package 2 Weight | 1.367 kg | 1.33 kg | 1.326 kg | 1.297 kg |
Unit Type of Package 3 | CAR | CAR | CAR | CAR |
Number of Units in Package 3 | 48 | 48 | 48 | 48 |
Package 3 Height | 19.315 cm | 19.6 cm | 19.5 cm | 19.5 cm |
Package 3 Width | 30.015 cm | 30 cm | 29.8 cm | 29.5 cm |
Package 3 Length | 39 cm | 39.5 cm | 39.6 cm | 39.5 cm |
Package 3 Weight | 11.5 kg | 11 kg | 11 kg | 11 kg |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Product number | A9N22424 | A9N22425 | A9N22426 | A9N22427 |
Product family | Multi9 | Multi9 | Multi9 | Multi9 |
Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
Product name | C65-DC | C65-DC | C65-DC | C65-DC |
Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
Short name of the product | C65N-DC | C65N-DC | C65N-DC | C65N-DC |
Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
Number of poles | 2P | 2P | 2P | 2P |
Number of protection poles | 2 | 2 | 2 | 2 |
Rated current [In] | 10 A in… Up to 40 °C | 16 A in… Up to 40 °C | 20 A in… Up to 40 °C | 25 A in… Up to 40 °C |
Network type | DC | DC | DC | DC |
Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
Trip curve | C | C | C | C |
Breaking ability | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
Supplemental Information | ||||
Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
Magnetic trip restrictions | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % |
Using Breaking Capability [ICS] | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC |
Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
Rated impulse withstand voltage [UIMP] | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 |
Width (multiple of 9mm) | 4 | 4 | 4 | 4 |
height | 84 mm | 84 mm | 84 mm | 84 mm |
width | 36 mm | 36 mm | 36 mm | 36 mm |
depth | 73.5 mm | 73.5 mm | 73.5 mm | 73.5 mm |
Product net weight | 220 g | 220 g | 220 g | 220 g |
Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² |
Tightening torque | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: |
Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
environment | ||||
Compliance with standards | IEC 60947-2 | GB 14048.2 | IEC 60947-2 | GB 14048.2 |
GB 14048.2 | IEC 60947-2 | GB 14048.2 | IEC 60947-2 | |
Product certification | CCC | CCC | CCC | CCC |
IEC CB report | IEC CB report | IEC CB report | IEC CB report | |
Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 3.537 cm | 3.6 cm | 3.544 cm | 3.542 cm |
Package 1 Width | 7.411 cm | 7.3 cm | 7.412 cm | 7.356 cm |
Package 1 Length | 8.367 cm | 8.4 cm | 8.369 cm | 8.354 cm |
Package 1 Weight | 207 g | 206 g | 213 g | 216.6 g |
Unit Type of Package 2 | BB1 | BB1 | BB1 | BB1 |
Number of Units in Package 2 | 6 | 6 | 6 | 6 |
Package 2 Height | 8.5 cm | 8.5 cm | 8.4 cm | 7.847 cm |
Package 2 Width | 8.9 cm | 8.9 cm | 9.1 cm | 9.018 cm |
Package 2 Length | 22 cm | 22.2 cm | 21.8 cm | 22.223 cm |
Package 2 Weight | 1.284 kg | 1.312 kg | 1.321 kg | 1.351 kg |
Unit Type of Package 3 | CAR | CAR | CAR | CAR |
Number of Units in Package 3 | 48 | 48 | 48 | 48 |
Package 3 Height | 19.8 cm | 19.7 cm | 19.5 cm | 19.8 cm |
Package 3 Width | 29.3 cm | 29.2 cm | 29.5 cm | 29.7 cm |
Package 3 Length | 39.1 cm | 39.8 cm | 38.8 cm | 40 cm |
Package 3 Weight | 10.697 kg | 10.887 kg | 11.02 kg | 11 kg |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Product number | A9N22428 | A9N22429 | A9N22430 | A9N22431 |
Product family | Multi9 | Multi9 | Multi9 | Multi9 |
Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
Product name | C65-DC | C65-DC | C65-DC | C65-DC |
Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
Short name of the product | C65N-DC | C65N-DC | C65N-DC | C65N-DC |
Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
Number of poles | 2P | 2P | 2P | 2P |
Number of protection poles | 2 | 2 | 2 | 2 |
Rated current [In] | 32 A in… Up to 40 °C | 40 A in… Up to 40 °C | 50 A in… Up to 40 °C | 63 A in… Up to 40 °C |
Network type | DC | DC | DC | DC |
Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
Trip curve | C | C | C | C |
Breaking ability | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 6 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
Supplemental Information | ||||
Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
Magnetic trip restrictions | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % | 8.5 x In +/- 20 % |
Using Breaking Capability [ICS] | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC | 6 kA 100 % according to IEC 60947-2 – 126 V DC |
Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
Rated impulse withstand voltage [UIMP] | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 | 6 kV according to IEC 60947-2 |
Width (multiple of 9mm) | 4 | 4 | 4 | 4 |
height | 84 mm | 84 mm | 84 mm | 84 mm |
width | 36 mm | 36 mm | 36 mm | 36 mm |
depth | 73.5 mm | 73.5 mm | 73.5 mm | 73.5 mm |
Product net weight | 220 g | 220 g | 220 g | 220 g |
Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…35 mm² | Tunnel terminals (upper or lower wiring) – 1…35 mm² | Tunnel terminals (upper or lower wiring) – 1…35 mm² |
Tightening torque | 3.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: |
Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
environment | ||||
Compliance with standards | IEC 60947-2 | IEC 60947-2 | GB 14048.2 | GB 14048.2 |
GB 14048.2 | GB 14048.2 | IEC 60947-2 | IEC 60947-2 | |
Product certification | IEC CB reports | CCC | IEC CB reports | CCC |
CCC | IEC CB report | CCC | IEC CB report | |
Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 7.36 cm | 3.52 cm | 8 cm | 3.525 cm |
Package 1 Width | 8.36 cm | 7.324 cm | 3.7 cm | 7.394 cm |
Package 1 Length | 3.54 cm | 8.348 cm | 9 cm | 8.324 cm |
Package 1 Weight | 225 g | 234.3 g | 241.3 g | 240.6 g |
Unit Type of Package 2 | BB1 | BB1 | BB1 | BB1 |
Number of Units in Package 2 | 6 | 6 | 6 | 6 |
Package 2 Height | 8.4 cm | 8.067 cm | 22.2 cm | 7.965 cm |
Package 2 Width | 9.5 cm | 8.957 cm | 8.2 cm | 8.837 cm |
Package 2 Length | 22.4 cm | 22.292 cm | 9.2 cm | 22.056 cm |
Package 2 Weight | 1.383 kg | 1.452 kg | 1.49 kg | 1.493 kg |
Unit Type of Package 3 | CAR | CAR | CAR | CAR |
Number of Units in Package 3 | 48 | 48 | 48 | 48 |
Package 3 Height | 20 cm | 19.6 cm | 19.4 cm | 19.13 cm |
Package 3 Width | 29.5 cm | 30 cm | 30 cm | 29.717 cm |
Package 3 Length | 39.6 cm | 39.5 cm | 40 cm | 39.8 cm |
Package 3 Weight | 11.534 kg | 12 kg | 12.46 kg | 12.5 kg |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,