Product number | A9N22000 | A9N22001 | A9N22002 | A9N22003 |
Product family | Multi9 | Multi9 | Multi9 | Multi9 |
Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
Product name | C65-DC | C65-DC | C65-DC | C65-DC |
Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
Short name of the product | C65H-DC | C65H-DC | C65H-DC | C65H-DC |
Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
Number of poles | 1P | 1P | 1P | 1P |
Number of protection poles | 1 | 1 | 1 | 1 |
Rated current [In] | 1 A in… Up to 40 °C | 2 A in… Up to 40 °C | 3 A in… Up to 40 °C | 4 A in… Up to 40 °C |
Network type | DC | DC | DC | DC |
Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
Trip curve | B | B | B | B |
Breaking ability | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
Supplemental Information | ||||
Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
Magnetic trip restrictions | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % |
Using Breaking Capability [ICS] | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC |
Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
Rated impulse withstand voltage [UIMP] | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 |
Width (multiple of 9mm) | 2 | 2 | 2 | 2 |
height | 84 mm | 84 mm | 84 mm | 84 mm |
width | 18 mm | 18 mm | 18 mm | 18 mm |
depth | 71.5 mm | 71.5 mm | 71.5 mm | 71.5 mm |
Product net weight | 110 g | 110 g | 110 g | 110 g |
Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² |
Tightening torque | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: |
Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
environment | ||||
Compliance with standards | GB 14048.2 | IEC 60947-2 | GB 14048.2 | GB 14048.2 |
IEC 60947-2 | GB 14048.2 | IEC 60947-2 | IEC 60947-2 | |
Product certification | IEC CB reports | CCC | CCC | CCC |
CCC | IEC CB report | IEC CB report | IEC CB report | |
Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 8.0 cm | 8 cm | 8 cm | 8 cm |
Package 1 Width | 1.8 cm | 1.8 cm | 1.8 cm | 1.8 cm |
Package 1 Length | 9.0 cm | 9 cm | 9 cm | 9 cm |
Package 1 Weight | 110.0 g | 107.1 g | 107.9 g | 106.4 g |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Product number | A9N22004 | A9N22005 | A9N22006 | A9N22007 |
Product family | Multi9 | Multi9 | Multi9 | Multi9 |
Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
Product name | C65-DC | C65-DC | C65-DC | C65-DC |
Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
Short name of the product | C65H-DC | C65H-DC | C65H-DC | C65H-DC |
Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
Number of poles | 1P | 1P | 1P | 1P |
Number of protection poles | 1 | 1 | 1 | 1 |
Rated current [In] | 6 A in… Up to 40 °C | 10 A in… Up to 40 °C | 16 A in… Up to 40 °C | 20 A in… Up to 40 °C |
Network type | DC | DC | DC | DC |
Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
Trip curve | B | B | B | B |
Breaking ability | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
Supplemental Information | ||||
Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
Magnetic trip restrictions | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % |
Using Breaking Capability [ICS] | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC |
Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
Rated impulse withstand voltage [UIMP] | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 |
Width (multiple of 9mm) | 2 | 2 | 2 | 2 |
height | 84 mm | 84 mm | 84 mm | 84 mm |
width | 18 mm | 18 mm | 18 mm | 18 mm |
depth | 71.5 mm | 71.5 mm | 71.5 mm | 71.5 mm |
Product net weight | 110 g | 110 g | 110 g | 110 g |
Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² |
Tightening torque | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: |
Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
environment | ||||
Compliance with standards | IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | GB 14048.2 |
GB 14048.2 | GB 14048.2 | GB 14048.2 | IEC 60947-2 | |
Product certification | IEC CB reports | IEC CB reports | CCC | CCC |
CCC | CCC | IEC CB report | IEC CB report | |
Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 8 cm | 8 cm | 8 cm | 8 cm |
Package 1 Width | 1.8 cm | 1.8 cm | 1.8 cm | 1.8 cm |
Package 1 Length | 9 cm | 9 cm | 9 cm | 9 cm |
Package 1 Weight | 103.9 g | 106.5 g | 108.5 g | 109.7 g |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Product number | A9N22008 | A9N22009 | A9N22010 | A9N22012 |
Product family | Multi9 | Multi9 | Multi9 | Multi9 |
Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
Product name | C65-DC | C65-DC | C65-DC | C65-DC |
Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
Short name of the product | C65H-DC | C65H-DC | C65H-DC | C65H-DC |
Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
Number of poles | 1P | 1P | 1P | 1P |
Number of protection poles | 1 | 1 | 1 | 1 |
Rated current [In] | 25 A in… Up to 40 °C | 32 A in… Up to 40 °C | 40 A in… Up to 40 °C | 63 A in… Up to 40 °C |
Network type | DC | DC | DC | DC |
Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
Trip curve | B | B | B | B |
Breaking ability | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
Supplemental Information | ||||
Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
Magnetic trip restrictions | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % |
Using Breaking Capability [ICS] | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC |
Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
Rated impulse withstand voltage [UIMP] | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 |
Width (multiple of 9mm) | 2 | 2 | 2 | 2 |
height | 84 mm | 84 mm | 84 mm | 84 mm |
width | 18 mm | 18 mm | 18 mm | 18 mm |
depth | 71.5 mm | 71.5 mm | 71.5 mm | 71.5 mm |
Product net weight | 110 g | 110 g | 110 g | 110 g |
Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…35 mm² | Tunnel terminals (upper or lower wiring) – 1…35 mm² |
Tightening torque | 2.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: |
Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
environment | ||||
Compliance with standards | IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | GB 14048.2 |
GB 14048.2 | GB 14048.2 | GB 14048.2 | IEC 60947-2 | |
Product certification | CCC | IEC CB reports | CCC | IEC CB reports |
IEC CB report | CCC | IEC CB report | CCC | |
Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 8.0 cm | 8.0 cm | 8.0 cm | 8.0 cm |
Package 1 Width | 1.8 cm | 1.8 cm | 1.8 cm | 1.8 cm |
Package 1 Length | 9.0 cm | 9.0 cm | 9.0 cm | 9.0 cm |
Package 1 Weight | 111.8 g | 116.3 g | 118.5 g | 126.4 g |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details