| Product number | A9N22000 | A9N22001 | A9N22002 | A9N22003 |
| Product family | Multi9 | Multi9 | Multi9 | Multi9 |
| Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
| Product name | C65-DC | C65-DC | C65-DC | C65-DC |
| Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
| Short name of the product | C65H-DC | C65H-DC | C65H-DC | C65H-DC |
| Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
| Number of poles | 1P | 1P | 1P | 1P |
| Number of protection poles | 1 | 1 | 1 | 1 |
| Rated current [In] | 1 A in… Up to 40 °C | 2 A in… Up to 40 °C | 3 A in… Up to 40 °C | 4 A in… Up to 40 °C |
| Network type | DC | DC | DC | DC |
| Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
| Trip curve | B | B | B | B |
| Breaking ability | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
| Supplemental Information | ||||
| Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
| Magnetic trip restrictions | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % |
| Using Breaking Capability [ICS] | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC |
| Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
| Rated impulse withstand voltage [UIMP] | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 |
| Width (multiple of 9mm) | 2 | 2 | 2 | 2 |
| height | 84 mm | 84 mm | 84 mm | 84 mm |
| width | 18 mm | 18 mm | 18 mm | 18 mm |
| depth | 71.5 mm | 71.5 mm | 71.5 mm | 71.5 mm |
| Product net weight | 110 g | 110 g | 110 g | 110 g |
| Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
| Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
| Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² |
| Tightening torque | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: |
| Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
| environment | ||||
| Compliance with standards | GB 14048.2 | IEC 60947-2 | GB 14048.2 | GB 14048.2 |
| IEC 60947-2 | GB 14048.2 | IEC 60947-2 | IEC 60947-2 | |
| Product certification | IEC CB reports | CCC | CCC | CCC |
| CCC | IEC CB report | IEC CB report | IEC CB report | |
| Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
| relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
| Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
| Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
| Packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE |
| Number of Units in Package 1 | 1 | 1 | 1 | 1 |
| Package 1 Height | 8.0 cm | 8 cm | 8 cm | 8 cm |
| Package 1 Width | 1.8 cm | 1.8 cm | 1.8 cm | 1.8 cm |
| Package 1 Length | 9.0 cm | 9 cm | 9 cm | 9 cm |
| Package 1 Weight | 110.0 g | 107.1 g | 107.9 g | 106.4 g |
| Contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months |
| Product number | A9N22004 | A9N22005 | A9N22006 | A9N22007 |
| Product family | Multi9 | Multi9 | Multi9 | Multi9 |
| Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
| Product name | C65-DC | C65-DC | C65-DC | C65-DC |
| Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
| Short name of the product | C65H-DC | C65H-DC | C65H-DC | C65H-DC |
| Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
| Number of poles | 1P | 1P | 1P | 1P |
| Number of protection poles | 1 | 1 | 1 | 1 |
| Rated current [In] | 6 A in… Up to 40 °C | 10 A in… Up to 40 °C | 16 A in… Up to 40 °C | 20 A in… Up to 40 °C |
| Network type | DC | DC | DC | DC |
| Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
| Trip curve | B | B | B | B |
| Breaking ability | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
| Supplemental Information | ||||
| Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
| Magnetic trip restrictions | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % |
| Using Breaking Capability [ICS] | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC |
| Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
| Rated impulse withstand voltage [UIMP] | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 |
| Width (multiple of 9mm) | 2 | 2 | 2 | 2 |
| height | 84 mm | 84 mm | 84 mm | 84 mm |
| width | 18 mm | 18 mm | 18 mm | 18 mm |
| depth | 71.5 mm | 71.5 mm | 71.5 mm | 71.5 mm |
| Product net weight | 110 g | 110 g | 110 g | 110 g |
| Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
| Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
| Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² |
| Tightening torque | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: | 2.5 N.m upper or lower wiring Power circuit: |
| Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
| environment | ||||
| Compliance with standards | IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | GB 14048.2 |
| GB 14048.2 | GB 14048.2 | GB 14048.2 | IEC 60947-2 | |
| Product certification | IEC CB reports | IEC CB reports | CCC | CCC |
| CCC | CCC | IEC CB report | IEC CB report | |
| Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
| relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
| Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
| Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
| Packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE |
| Number of Units in Package 1 | 1 | 1 | 1 | 1 |
| Package 1 Height | 8 cm | 8 cm | 8 cm | 8 cm |
| Package 1 Width | 1.8 cm | 1.8 cm | 1.8 cm | 1.8 cm |
| Package 1 Length | 9 cm | 9 cm | 9 cm | 9 cm |
| Package 1 Weight | 103.9 g | 106.5 g | 108.5 g | 109.7 g |
| Contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months |
| Product number | A9N22008 | A9N22009 | A9N22010 | A9N22012 |
| Product family | Multi9 | Multi9 | Multi9 | Multi9 |
| Product family | Multi 9 | Multi 9 | Multi 9 | Multi 9 |
| Product name | C65-DC | C65-DC | C65-DC | C65-DC |
| Product type | Small circuit breakers | Small circuit breakers | Small circuit breakers | Small circuit breakers |
| Short name of the product | C65H-DC | C65H-DC | C65H-DC | C65H-DC |
| Product application | Distribution protection | Distribution protection | Distribution protection | Distribution protection |
| Number of poles | 1P | 1P | 1P | 1P |
| Number of protection poles | 1 | 1 | 1 | 1 |
| Rated current [In] | 25 A in… Up to 40 °C | 32 A in… Up to 40 °C | 40 A in… Up to 40 °C | 63 A in… Up to 40 °C |
| Network type | DC | DC | DC | DC |
| Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
| Trip curve | B | B | B | B |
| Breaking ability | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 | 10 kA Icu in… The upper 126 V DC complies with IEC 60947-2 |
| Supplemental Information | ||||
| Rated operating voltage [UE] | 126 V DC | 126 V DC | 126 V DC | 126 V DC |
| Magnetic trip restrictions | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % | 5.5 x In +/- 20 % |
| Using Breaking Capability [ICS] | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC | 7.5 kA 75 % according to IEC 60947-2 – 126 V DC |
| Current limit level | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 | 3 Complies with IEC 60947-2 |
| Rated impulse withstand voltage [UIMP] | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 | 5 kV in accordance with IEC 60947-2 |
| Width (multiple of 9mm) | 2 | 2 | 2 | 2 |
| height | 84 mm | 84 mm | 84 mm | 84 mm |
| width | 18 mm | 18 mm | 18 mm | 18 mm |
| depth | 71.5 mm | 71.5 mm | 71.5 mm | 71.5 mm |
| Product net weight | 110 g | 110 g | 110 g | 110 g |
| Mechanical life | 20000 times | 20000 times | 20000 times | 20000 times |
| Electrical life | 10000 times | 10000 times | 10000 times | 10000 times |
| Wiring capability | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…25 mm² | Tunnel terminals (upper or lower wiring) – 1…35 mm² | Tunnel terminals (upper or lower wiring) – 1…35 mm² |
| Tightening torque | 2.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: | 3.5 N.m upper or lower wiring Power circuit: |
| Leakage current protection | No leakage protection | No leakage protection | No leakage protection | No leakage protection |
| environment | ||||
| Compliance with standards | IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | GB 14048.2 |
| GB 14048.2 | GB 14048.2 | GB 14048.2 | IEC 60947-2 | |
| Product certification | CCC | IEC CB reports | CCC | IEC CB reports |
| IEC CB report | CCC | IEC CB report | CCC | |
| Resistance to humidity and heat | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 | 2 Complies with IEC 60068-1 |
| relative humidity | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C | 95 % in… Up to 55 °C |
| Operating temperature | -30… 70 °C | -30… 70 °C | -30… 70 °C | -30… 70 °C |
| Storage ambient temperature | -40… 85 °C | -40… 85 °C | -40… 85 °C | -40… 85 °C |
| Packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE |
| Number of Units in Package 1 | 1 | 1 | 1 | 1 |
| Package 1 Height | 8.0 cm | 8.0 cm | 8.0 cm | 8.0 cm |
| Package 1 Width | 1.8 cm | 1.8 cm | 1.8 cm | 1.8 cm |
| Package 1 Length | 9.0 cm | 9.0 cm | 9.0 cm | 9.0 cm |
| Package 1 Weight | 111.8 g | 116.3 g | 118.5 g | 126.4 g |
| Contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months |