MS9-LF-G-CUV Festo Filter

$ 132.50

MS9 series pneumatic filter with 5 µm filtration and fully automatic condensate drain. Features a sintered filter with centrifugal separator and 12 bar max pressure.

SKU Festo-564109 Category
Compressed air filters

MS9-LF-G-CUV Festo Filter

Model Identifier MS9-LF-G-CUV
Official Part Number 564109
GTIN Standard 4052568211400

Technical Overview

The Festo MS9-LF-G-CUV is a high-performance size 9 compressed air filter from the MS series, engineered for efficient air preparation. It utilizes a sintered filter design combined with a centrifugal separator to remove contaminants down to 5 µm, achieving a condensate separation efficiency greater than 75%. This unit features a fully automatic condensate drain and is constructed from robust die-cast aluminium for the housing and sub-base, with a wrought aluminium alloy bowl. It is designed for vertical mounting and is suitable for both compressed air and inert gases within an operating pressure range of 2 to 12 bar.

Key Features

  • Sintered filter with centrifugal separator design
  • 5 µm filtration grade for particle removal
  • Fully automatic condensate drain
  • Vertical mounting position (+/-5°)
  • Cleanroom suitability Class 7 according to ISO 14644-1
  • Moderate corrosion stress resistance (CRC 2)
  • RoHS-compliant materials
  • Wrought aluminium alloy bowl for durability

Fully automatic condensate drain with a high degree of condensate separation exceeding 75%.

Technical Specification Matrix

ParameterValue
Size9
SeriesMS
Mounting positionVertical +/-5°
Grade of filtration5 µm
Condensate drainFully automatic
DesignSintered filter with centrifugal separator
Degree of condensate separation>75 %
Symbol00991520
Operating pressure2 bar ... 12 bar
Operating mediumCompressed air to ISO 8573-1:2010 [7:9:-] Inert gases
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitabilityClass 7 according to ISO 14644-1
Storage temperature5 °C ... 60 °C
Air purity class at outputCompressed air to ISO 8573-1:2010 [6:8:4]
Media temperature-10 °C ... 60 °C
Ambient temperature-10 °C ... 60 °C
Pore size5 µm
Product weight2000 g
Type of mountingWith accessories
Material coveringPA-reinforced
Material spin discPOM
Material filter carrierPOM
Note on materialsRoHS-compliant
Material sub-baseDie-cast aluminium
Material mounting bracketDie-cast aluminium
Material filterPE
Material housingDie-cast aluminium
Material module connectorDie-cast aluminium
Material bowlWrought aluminium alloy
Material cup sealNBR
Material screenPA
Material separating platePOM

Industrial Applications

1. Main Air Supply for Automotive Paint Shops

Deployed as the primary stage filtration unit at the entrance of automotive painting zones. The unit filters large volumes of compressed air required for paint robots and pneumatic atomizers, ensuring the removal of bulk contaminants like pipe scale and condensate before finer filtration stages.

Problem Solved

Prevents 'fisheye' and cratering defects in paint finishes caused by Paint-Wetting Impairment Substances (PWIS). The specific 'LABS/PWIS conformity (VDMA24364-B1/B2-L)' ensures the filter materials do not release silicones or contaminants that ruin paint adhesion, while the fully automatic drain eliminates the need for maintenance personnel to enter sensitive clean zones to empty bowls.

LABS/PWIS ConformityVDMA24364-B1/B2-LFully automatic condensate drainSize 9 High FlowISO 8573-1:2010 [6:8:4]

2. Bulk Nitrogen Gas Distribution Network

Installed as a high-flow particulate filter in centralized inert gas grids used for heat treatment furnaces or electronics inerting. The unit processes Nitrogen (N2) at pressures up to 12 bar, removing particulate matter generated from carbon steel piping networks before the gas reaches precision flow controllers.

Problem Solved

Solves the issue of valve seat erosion and clogging in downstream mass flow controllers caused by rust and dust in aging pipework. The 'Inert gases' compatibility and 'Wrought aluminium alloy' bowl provide the necessary safety and material compatibility for handling pressurized nitrogen in industrial environments where plastic bowls might degrade or pose safety risks.

Inert gas filtrationOperating pressure 2-12 barWrought aluminium alloy bowl5 µm filtrationCentrifugal separator

3. Semiconductor Sub-Fab Utility Air Prep

Utilized in the sub-fabrication level of semiconductor plants to filter general pneumatic air for tool actuation (e.g., wafer handling robots). The unit serves as the robust pre-filter stage, ensuring air quality meets the facility's background cleanliness requirements without frequent maintenance interventions.

Problem Solved

Maintains strict 'ISO Class 7' cleanroom compliance for the facility's air background level. The 'Fully automatic drain' is critical here as sub-fab areas are often cramped and hard to access for manual maintenance. The 5 µm pore size effectively protects downstream sterile filters (0.01 µm) from premature blinding by capturing 75% of condensate and coarse dust.

Cleanroom Class 7ISO 14644-1Fully automatic drainCondensate separation >75%Moderate corrosion stress CRC 2

[Download-Datasheet]