Contact Us:
sales@inosaki.com

Modicon M340 – Processor Modules – Schneider Modules

$ 559.02$ 1,295.14

SKU N/A Category

Specifications

Main
Part Number BMXP342000 BMXP3420102 BMXP342020
Range of product Modicon M340 automation platform Modicon M340 automation platform Modicon M340 automation platform
Product or component type Processor module Processor module Processor module
Number of racks 1 4 4
Number of slots 11 11 11
discrete I/O processor capacity 1024 I/O single-rack configuration 1024 I/O multi-rack configuration
704 I/O single-rack configuration
1024 I/O multi-rack configuration
704 I/O single-rack configuration
analogue I/O processor capacity 256 I/O multi-rack configuration
66 I/O single-rack configuration
256 I/O multi-rack configuration
66 I/O single-rack configuration
256 I/O multi-rack configuration
66 I/O single-rack configuration
Number of application specific channel 36 36 36
monitoring Diagnostic counters Modbus
Event counters Modbus
Diagnostic counters Modbus
Event counters Modbus
Diagnostic counters Modbus
Event counters Modbus
Complementary
Control channels Programmable loops Programmable loops Programmable loops
integrated connection type Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3…19.2 kbit/s full duplex
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
USB port at 12 Mbit/s
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3…19.2 kbit/s full duplex
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
USB port at 12 Mbit/s
CANopen master bus SUB-D 9, transmission mode: 2 twisted shielded pairs at 20 kbit/s…1 Mbit/s
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3…19.2 kbit/s full duplex
Non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
Non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3…19.2 kbit/s half duplex
USB port at 12 Mbit/s
Ethernet TCP/IP RJ45, transmission mode: 1 twisted pair at 10/100 Mbit/s
communication module processor capacity 2 Ethernet communication module
4 AS-Interface module
2 Ethernet communication module
4 AS-Interface module
2 Ethernet communication module
4 AS-Interface module
number of devices per segment 0…32 (character mode)
0…32 (Modbus)
0…32 (character mode)
0…32 (Modbus)
0…16 for <205 m (CANopen)
0…32 for <185 m (CANopen)
0…64 for <160 m (CANopen)
0…32 (character mode)
0…32 (Modbus)
number of devices 2 point-to-point character mode
2 point-to-point Modbus
2 point-to-point character mode
2 point-to-point Modbus
2 point-to-point character mode
2 point-to-point Modbus
bus length 0…10 m serial link non isolated character mode segment
0…10 m serial link non isolated Modbus segment
0…1000 m serial link isolated character mode segment
0…1000 m serial link isolated Modbus segment
0…15 m character mode point-to-point
0…15 m Modbus point-to-point
0…10 m serial link non isolated character mode segment
0…10 m serial link non isolated Modbus segment
0…1000 m serial link isolated character mode segment
0…1000 m serial link isolated Modbus segment
0…15 m character mode point-to-point
0…15 m Modbus point-to-point
0…10 m serial link non isolated character mode segment
0…10 m serial link non isolated Modbus segment
0…1000 m serial link isolated character mode segment
0…1000 m serial link isolated Modbus segment
0…15 m character mode point-to-point
0…15 m Modbus point-to-point
maximum tap links length <15 m serial link non isolated character mode segment
<15 m serial link non isolated Modbus segment
<40 m serial link isolated character mode segment
<40 m serial link isolated Modbus segment
<15 m serial link non isolated character mode segment
<15 m serial link non isolated Modbus segment
<40 m serial link isolated character mode segment
<40 m serial link isolated Modbus segment
<15 m serial link non isolated character mode segment
<15 m serial link non isolated Modbus segment
<40 m serial link isolated character mode segment
<40 m serial link isolated Modbus segment
number of addresses 0…248 for character mode
0…248 for Modbus
0…248 for character mode
0…248 for Modbus
0…248 for character mode
0…248 for Modbus
requests 1 K data bytes per request character mode
252 data bytes per RTU request Modbus
504 data bytes per ASCII request Modbus
1 K data bytes per request character mode
252 data bytes per RTU request Modbus
504 data bytes per ASCII request Modbus
1 K data bytes per request character mode
252 data bytes per RTU request Modbus
504 data bytes per ASCII request Modbus
control parameter One CRC on each frame (RTU) Modbus
One LRC on each frame (ASCII) character mode
One LRC on each frame (ASCII) Modbus
One CRC on each frame (RTU) Modbus
One LRC on each frame (ASCII) character mode
One LRC on each frame (ASCII) Modbus
One CRC on each frame (RTU) Modbus
One LRC on each frame (ASCII) character mode
One LRC on each frame (ASCII) Modbus
memory description Internal RAM 4096 kB
Internal RAM 256 kB data
Internal RAM 3584 kB program constants and symbols
Supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
Supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
Internal RAM 4096 kB
Internal RAM 256 kB data
Internal RAM 3584 kB program constants and symbols
Supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
Internal RAM 4096 kB
Internal RAM 256 kB data
Internal RAM 3584 kB program constants and symbols
Supplied memory card (BMXRMS008MP) activation of standard web server, class B10
maximum size of object areas 128 kB unlocated internal data
16250 %Mi located internal bits
32464 %MWi internal words located internal data
32760 %KWi constant words located internal data
256 kB unlocated internal data
32634 %Mi located internal bits
256 kB unlocated internal data
32634 %Mi located internal bits
default size of object areas 128 %KWi constant words located internal data
256 %Mi located internal bits
512 %MWi internal words located internal data
1024 %MWi internal words located internal data
256 %KWi constant words located internal data
512 %Mi located internal bits
1024 %MWi internal words located internal data
256 %KWi constant words located internal data
512 %Mi located internal bits
Application structure 1 cyclic/periodic master task
1 periodic fast task
No auxiliary task
32 event tasks
No auxiliary task
1 cyclic/periodic master task
1 periodic fast task
64 event tasks
1 cyclic/periodic master task
1 periodic fast task
No auxiliary task
64 event tasks
execution time per instruction 0.18 µs Boolean
0.26 µs double-length words
0.38 µs single-length words
1.74 µs floating points
0.12 µs Boolean
0.17 µs double-length words
0.25 µs single-length words
1.16 µs floating points
0.12 µs Boolean
0.17 µs double-length words
0.25 µs single-length words
1.16 µs floating points
number of instructions per ms 4.2 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
5.4 Kinst/ms 100 % Boolean
6.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
8.1 Kinst/ms 100 % Boolean
6.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
8.1 Kinst/ms 100 % Boolean
system overhead 0.2 ms for fast task
1.05 ms for master task
0.13 ms for fast task
0.7 ms for master task
0.13 ms for fast task
0.7 ms for master task
current consumption 72 mA at 24 V DC 90 mA at 24 V DC 95 mA at 24 V DC
Supply Internal power supply via rack Internal power supply via rack Internal power supply via rack
Marking CE CE CE
status LED 1 LED (green) processor running (RUN)
1 LED (red) I/O module fault (I/O)
1 LED (red) memory card fault (CARD ERR)
1 LED (red) processor or system fault (ERR)
1 LED (yellow) activity on Modbus (SER COM)
1 LED (green) integrated machine/installation bus operational (CAN RUN)
1 LED (green) processor running (RUN)
1 LED (red) I/O module fault (I/O)
1 LED (red) integrated machine/installation bus fault (CAN ERR)
1 LED (red) memory card fault (CARD ERR)
1 LED (red) processor or system fault (ERR)
1 LED (yellow) activity on Modbus (SER COM)
1 LED (green) activity on Ethernet network (ETH ACT)
1 LED (green) processor running (RUN)
1 LED (green) status of Ethernet network (ETH STS)
1 LED (red) data rate (ETH 100)
1 LED (red) I/O module fault (I/O)
1 LED (red) memory card fault (CARD ERR)
1 LED (red) processor or system fault (ERR)
1 LED (yellow) activity on Modbus (SER COM)
Net weight 0.2 kg 0.21 kg 0.205 kg
Environment
Ambient air temperature for operation 0…60 °C 0…60 °C 0…60 °C
relative humidity 10…95 % without condensation 10…95 % without condensation 10…95 % without condensation
IP degree of protection IP20 IP20 IP20
Protective treatment TC TC TC
Directives 2014/35/EU – low voltage directive
2014/30/EU – electromagnetic compatibility
2014/35/EU – low voltage directive
2014/30/EU – electromagnetic compatibility
2014/35/EU – low voltage directive
2014/30/EU – electromagnetic compatibility
product certifications CE
UL
CSA
RCM
EAC
Merchant Navy
CE
UL
CSA
RCM
EAC
Merchant Navy
CE
UL
CSA
RCM
EAC
Merchant Navy
standards EN 61131-2
EN/IEC 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
IACS E10
EN/IEC 61000-6-5, interface type 1 and type 2
EN/IEC 61850-3, location G
EN 61131-2
EN/IEC 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
IACS E10
EN/IEC 61000-6-5, interface type 1 and type 2
EN/IEC 61850-3, location G
EN 61131-2
EN/IEC 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
IACS E10
EN/IEC 61000-6-5, interface type 1 and type 2
EN/IEC 61850-3, location G
environmental characteristic Hazardous location class I division 2 Hazardous location class I division 2 Hazardous location class I division 2
Packing Units
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 5.5 cm 5.5 cm 5.5 cm
Package 1 Width 11.0 cm 11.0 cm 11.0 cm
Package 1 Length 11.5 cm 11.6 cm 11.5 cm
Package 1 Weight 240.0 g 250.0 g 248.0 g
Unit Type of Package 2 S02 S02 S02
Number of Units in Package 2 15 15 15
Package 2 Height 15.0 cm 15.0 cm 15.0 cm
Package 2 Width 30.0 cm 30.0 cm 30.0 cm
Package 2 Length 40.0 cm 40.0 cm 40.0 cm
Package 2 Weight 3.915 kg 4.0 kg 3.98 kg
Contractual warranty
Warranty 18 months 18 months 18 months

Additional information

Weight N/A
Dimensions N/A

Related Products

Mitutoyo_Accessories_937179T
M24
SICK_sensor_Magnetic cylinder sensor_MZT7_MZT7-03VNS-KWB
SICK_sensor_Photoelectric_sensor_W4S-3 Inox Hygiene_WTB4S-3P1162H
SMC_Assembly_IZG10-NT
Omron_Temperature_Controllers_E5AC-800
Select your currency