| Main information | |
| Part Number | C2536E250 |
| Product Series | ComPacT new generation |
| Product Series | ComPacT NSX100…250 new generation |
| product type | Trip unit |
| Trip unit name | MicroLogic 6.2E |
| Trip unit type | Electronic |
| scope of application | ComPacT new generation NSX250 |
| Applications | Distribution protection |
| number of poles | 3P |
| Description of protection pole | 3D |
| Trip unit protection function | LSIG |
| protection type | L : for overload protection (long time delay) |
| S : for short circuit short time delay protection | |
| I : for short circuit instantaneous protection | |
| G : for ground fault protection | |
| Trip unit rating | 250 A at 40 °C |
| Rated working voltage [Ue] | 690V AC 50/60Hz |
| Grid type | AC |
| grid frequency | 50/60Hz |
| Circuit breaker mounting mode | Fixed |
| Additional information | |
| Long-time pick-up adjustment type Ir (thermal protection) | 9 steps adjustable |
| [Ir] long-time protection pick-up adjustment range | 100…250A |
| Long-time protection delay adjustment type tr | Adjustable |
| [tr] long-time protection delay adjustment range | 15…400 s at 1.5 x Ir |
| 0.35…11 s at 7.2 x Ir | |
| 0.5…16 s at 6 x Ir | |
| hot memory | 20 minutes before tripping and after tripping |
| Short-time protection pick-up adjustment type Isd | 9 steps adjustable |
| [Isd] Short-time protection pick-up adjustment range | 1.5…10 x Ir |
| Short-time protection delay adjustment type tsd | Adjustable |
| [tsd] Short-time protection delay adjustment range | 0…0.4 s inverse time off I²t=off |
| 0.1…0.4 s inverse time on I²t=on | |
| Instantaneous protection pick-up adjustment type II | Adjustable |
| [Ii] Instantaneous protection pick-up adjustment range | 1.5…12 x In |
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
| [Ig] ground-fault protection pick-up adjustment range | 0.4…1 x In for In = 40 A |
| 0.2…1 x In for In > 40 A | |
| Ig enable on/off | |
| Ground-fault protection time delay adjustment type tg | Adjustable |
| [tg] ground-fault protection time delay adjustment range | 0…0.4 s inverse time off I²t=off |
| 0.1…0.4 s inverse time on I²t=on | |
| Leakage current protection | No leakage protection |
| Zone Selective Interlocking ZSI | Have |
| local signal indication | LED indicator (green) for function available: |
| LED 105 % Ir (red) for overload: | |
| LED 90 % Ir (orange) for overload: | |
| display type | LCD display |
| measurement type | Meter |
| data communication | Energy Metering |
| Protection and Alarm Settings | |
| Timestamp History and Event Meters | |
| Instantaneous and Demanded Values | |
| Holding Indicators | |
| Demanded Current and Power | |
| Power Quality | |
| Meter/Micrometer | |
| Electrical data logging | Hold indicator |
| environment | |
| Standards compliant | TM-D |
| Electric Shock Protection Level | Class II |
| pollution level | 3 Conforming to IEC 60947-1 |
| IP protection class | IP40 complies with screwed |
| operating temperature | -25…70°C |
| storage environment temperature | -40…85°C |
| packaging unit | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.8 cm |
| Package 1 Width | 11.0cm |
| Package 1 Length | 15.0cm |
| Package 1 Weight | 555.0g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 11 |
| Package 2 Height | 30cm |
| Package 2 Width | 30cm |
| Package 2 Length | 40cm |
| Package 2 Weight | 6.551kg |
| Contract warranty | |
| Warranty | 18 months |