Sale!

Festo 196139 Direct 3/2 Normally Open Valve, 24 V DC, 100 l/min

Original price was: USD 107.64.Current price is: USD 93.08.

10 mm sub-base valve with spring reset, 1.7 ms on/2 ms off switching, 14 mm grid, two-pin plug, holding-current reduction and restricted reverse flow.

SKU Festo-196139 Category
Festo Solenoid Valves

Festo MHA2-MS1H-3/2O-2 Direct-Acting Solenoid Valve

BrandFesto
Model IdentifierMHA2-MS1H-3/2O-2
Official Part Number196139

Technical Overview

The Festo MHA2-MS1H-3/2O-2 is a direct-acting, normally open 3/2-way solenoid valve with mechanical spring reset and 100 l/min standard nominal flow. Its 10 mm body uses a sub-base interface, a 2 mm nominal passage and a 14 mm mounting grid with 4 mm minimum spacing between valves. At 24 V DC, specified switching times are 1.7 ms on and 2 ms off, with holding-current reduction and a two-pin plug. The normal pressure range is −0.9 to 8 bar, restricted to −0.9 to 1 bar for reversible operation. The 60 g IP65 assembly has temperature limits dependent on switching frequency.

Direct-acting normally open 3/2-way sub-base valve with 100 l/min nominal flow, 24 V DC actuation, 1.7 ms on/2 ms off timing and IP65.

Key Features

  • Normally open single-solenoid 3/2-way function with mechanical spring reset
  • Direct-acting pressure-relief poppet construction; 2 mm nominal size
  • 100 l/min standard nominal flow to DIN 1343
  • 10 mm construction width and 14 mm grid; 4 mm minimum inter-valve spacing
  • −0.9 to 8 bar operating range; reversible operation restricted to −0.9 to 1 bar
  • 1.7 ms on and 2 ms off switching; +10%/−30% switching-time tolerances
  • 330 Hz maximum switching frequency, subject to frequency-dependent temperature limits
  • 24 V DC two-pin plug; coil high-current phase 5.0 W and low-current phase 1.25 W
  • Holding-current reduction, spark arresting, protective circuit and bipolar reverse-polarity protection
  • 60 g product weight, IP65, non-detenting manual override and Class 6 cleanroom suitability

Switch a sub-base pneumatic branch with 1.7 ms on/2 ms off component timing and direct actuation in a 10 mm valve body.

Technical Specification Matrix

ParameterValue
Valve function3/2-way, single solenoid, open
Type of actuationElectrical
Construction width10 mm
Standard nominal flow rate (standardised to DIN 1343)100 l/min
pneumatic working portSub-base
Operating voltage24 V DC
Operating pressure-0.09 MPa...0.8 MPa; -0.9 bar...8 bar; -13.05 psi...116 psi
DesignPressure relief poppet valve
Type of resetMechanical spring
Degree of protectionIP65
ApprovalRCM; c UL us - Recognised (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Nominal size2 mm
Mounting grid pitch14 mm
Minimum inter-valve spacingMinimum distance between the valves is 4 mm
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Manual overrideNon-detenting
Type of pilotingDirect
Flow directionReversible with restrictions
lapUnderlap
Reverse polarity protectionBipolar
Additional functionsSpark arresting; Holding current reduction; Protective circuit
Operating pressure, reversible-0.09 MPa...0.1 MPa; -0.9 bar...1 bar; -13.05 psi...14.5 psi
Max. switching frequency330 Hz
Switching time off2 ms
Switching time on1.7 ms
Tolerance switching time off+10%/-30%
Tolerance switching time on+10%/-30%
Switching time dispersion from 1 Hz0.2 ms
Duty cycle100%
Characteristic coil data24 V DC: low-current phase 1.25 W, high-current phase 5.0 W
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Restrictions for environmental and media temperatureAs a function of switching frequency (see graph)
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 6 according to ISO 14644-1
Media temperature-5 °C...40 °C
Ambient temperature-5 °C...40 °C
Physical Weight (kg)0.06
Electrical connection2-pin; Plug
Type of mountingOn sub-base
Pneumatic connection, port 11Sub-base
Pneumatic connection, port 2Sub-base
Pneumatic port 33Sub-base
Note on materialsRoHS compliant
Material sealsHNBR; NBR
Material housingDie-cast zinc, coated
Material screwsGalvanised steel

Industrial Applications

1. Interrupting Airflow to a Small Process Nozzle

A process station normally supplies a small air nozzle and needs an electrical command to interrupt its feed. The normally open 3/2-way valve supplies the unactuated flow arrangement, with direct actuation and specified 1.7 ms on/2 ms off component switching times. Its 100 l/min nominal flow characterizes the valve, while the nozzle response depends on the connected volume and tubing.

Problem Solved

The normally open routing supports the default feed condition, while direct electrical switching provides a defined command point for interrupting or changing that pneumatic path.

3/2 normally open 1.7 ms on / 2 ms off 100 l/min nominal

2. Electrical Commands to a Pneumatic Pilot Circuit

An automated fixture uses a downstream pneumatic control element and needs an electrical-to-pneumatic command stage. This direct-acting 3/2 valve switches its working path from a 24 V DC command and returns by mechanical spring. Sub-base connections group the supply, working and exhaust interfaces at the valve station, while the two-pin plug defines the electrical connection.

Problem Solved

The valve converts an electrical sequence command into a pneumatic switching state, with direct actuation and mechanical spring reset providing the command stage for the downstream circuit.

Direct actuation 24 V DC Mechanical spring reset

3. Restricted-Pressure Vacuum Path Switching

A handling circuit requires a small directional valve whose working paths can operate below atmospheric pressure. Festo permits reversible operation for this model within the restricted −0.9 to 1 bar pressure range, distinct from its ordinary −0.9 to 8 bar rating. The direct-acting design switches without a separate pilot-air pressure requirement, with the sub-base providing the three pneumatic interfaces.

Problem Solved

Documented reversible low-pressure operation provides a valve basis for a vacuum-path circuit, while direct actuation avoids introducing a separate pneumatic pilot supply to switch that component.

−0.9 to 1 bar reversible Direct-acting Sub-base interface