LUT9U-P124L – Luminescence Sensors – SICK Sensor
$ 2,008.59
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1079119
Luminescence Sensor Model: LUT9U-P124L
OEM Spec Ref
Features
Dimensions (W x H x D) | 30.4 mm x 53 mm x 80 mm |
Sensing distance | 20 mm 1) |
Housing design (light emission) | Rectangular |
Working range | 10 mm … 40 mm |
Light source | LED, Ultraviolet light 2) |
Wave length | 375 nm |
Light emission | Long side |
Light spot size | 3 mm x 9 mm |
Light spot direction | Vertical |
Receiving filters | BP 420 |
Receiving range | 415 nm … 425 nm |
Adjustment | Teach-in button
IO-Link (optional) |
Output function | Light switching 3) |
- 1) From front edge of lens.
- 2) Average service life: 100,000 h at TU = +25 °C.
- 3) L/D switching via teach-in or IO-Link.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | < 100 mA 3) |
Switching frequency | 0.5 kHz 4)
2.5 kHz 6.5 kHz Adjustable |
Response time | 1 ms 5)
200 µs 75 µs |
Switching output | PNP |
Switching output (voltage) | PNP: HIGH = VS– ≤ 2 V / LOW approx. 0 V |
Switching mode | Light switching |
Analog output | 0 mA … 13 mA |
Output current Imax. | 100 mA |
Time delay | Switch-off delay, 0 ms / 10 ms / 20 ms, adjustable (0 ms = default) |
Connection type | Male connector M12, 4-pin |
Protection class | II 6) |
Circuit protection | UV connections, reverse polarity protected
Output Q short-circuit protected Interference pulse suppression |
Enclosure rating | IP67 |
Weight | 400 g |
Housing material | Metal, zinc diecast |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) With light/dark ratio 1:1, without timer stage.
- 5) Signal transit time with resistive load.
- 6) Reference voltage DC 50 V.
Communication interface
Communication interface | IO-Link (IO-Link V1.0) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure | Bit 0 = switching signal QL1
Bit 1 … 5 = empty Bit 6 … 15 = Analog Measurment Value |
VendorID | 26 |
DeviceID HEX | 80000F |
DeviceID DEC | 8388623 |
Ambient operating temperature | –10 °C … +55 °C |
Ambient storage temperature | –25 °C … +75 °C |
Shock load | According to IEC 60068 |
Weight | 0.364 kg |
---|---|
Dimensions | 8.0 × 4.0 × 13.0 cm |