LRS-100 Series- 100W Single Output Switching Power Supply – Mean Well

$ 21.78$ 23.98

SKU: N/A

Product Details

Mean Well LRS Switch Mode Power Supply

LRS-100 series is a 100W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V.

In addition to the high efficiency up to 91%, the design of metallic mesh case enhances the heat dissipation of LRS-100 that the whole series operates from -30℃ through 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. LRS-100 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as TUV BS EN/EN2368-1,BS EN/ EN60335- 1, BS EN/ EN61558- 1/- 2- 16, UL62368- 1 and GB4943. LRS- 100 series serves as a high price- to- performance power supply solution for various industrial applications.

Features :

‧Universal AC input / Full range

‧Withstand 300VAC surge input for 5 second

‧Protections: Short circuit / Overload / Over voltage

‧Cooling by free air convection

‧Miniature size and 1U low profile

‧Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, 2-16 for household appliances

‧Operating altitude up to 5000 meters (Note.7)

‧Withstand 5G vibration test

‧LED indicator for power on

‧No load power consumption<0.3W

‧Over voltage category Ⅲ

‧100% full load burn-in test

‧High operating temperature up to 70℃

‧High efficiency, long life and high reliability

SPECIFICATION

MODEL LRS-100-3.3 LRS-100-5 LRS-100-12 LRS-100-15 LRS-100-24 LRS-100-36 LRS-100-48
 

 

 

 

 

OUTPUT

DC VOLTAGE 3.3V 5V 12V 15V 24V 36V 48V
RATED CURRENT 20A 18A 8.5A 7A 4.5A 2.8A 2.3A
CURRENT RANGE 0 ~ 20A 0 ~ 18A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.8A 0 ~ 2.3A
RATED POWER 66W 90W 102W 105W 108W 100.8W 110.4W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 120mVp-p 150mVp-p 200mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 2.97 ~ 3.6V 4.5 ~ 5.5V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 32.4 ~ 39.6V 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION Note.5 ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 500ms, 30ms/230VAC         500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.) 55ms/230VAC       10ms/115VAC at full load
 

 

INPUT

VOLTAGE RANGE 85 ~ 264VAC         120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 84.5% 86% 88% 88.5% 90% 90.5% 91%
AC CURRENT (Typ.) 1.9A/115VAC          1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A/230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
 

 

PROTECTION

OVER LOAD 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
 

 

ENVIRONMENT

WORKING TEMP. -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
 

 

 

SAFETY & EMC

(Note 8)

 

SAFETY STANDARDS

UL 62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1,BSMI CNS14336-1, EAC TP TC 004,S/NZS62368.1(by CB),KC K60950-1(for LRS-100-12/24 only), BIS IS13252(Part1):

2010/IEC 60950-1: 2005 approved

WITHSTAND VOLTAGE I/P-O/P:4KVAC I/P-FG:2KVAC  O/P-FG:1.25KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, criteria A, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)
 

OTHERS

MTBF 720.6K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION 129*97*30mm (L*W*H)
PACKING 0.34Kg ; 40pcs/14.6Kg/0.92CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation.

4.  Line regulation is measured from low line to high line at rated load.

5.  Load regulation is measured from 0% to 100% rated load.

6.  Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

7.  The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).

8.  The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.

 