$ 133.40
input | |
type of the power supply network | 1-phase AC or DC |
supply voltage at AC | |
● minimum rated value | 100 V |
● maximum rated value | 240 V |
● initial value | 85 V |
● full-scale value | 264 V |
input voltage at DC | 110 … 300 V |
wide range input | Yes |
overvoltage overload capability | 300 V AC for 1 s |
buffering time for rated value of the output current in the event of power failure minimum |
40 ms |
operating condition of the mains buffering | at Vin = 187 V |
line frequency | 50/60 Hz |
line frequency | 47 … 63 Hz |
input current | |
● at rated input voltage 120 V | 0.71 A |
● at rated input voltage 230 V | 0.37 A |
current limitation of inrush current at 25 °C maximum | 50 A |
I2t value maximum | 3 A²·s |
fuse protection type | internal |
fuse protection type in the feeder | Recommended miniature circuit breaker: from 10 A characteristic B or from 6 A characteristic C |
output | |
voltage curve at output | Controlled, isolated DC voltage |
output voltage at DC rated value | 5 V |
output voltage | |
● at output 1 at DC rated value | 5 V |
output voltage adjustable | Yes; via potentiometer |
adjustable output voltage | 4.6 … 5.4 V |
relative overall tolerance of the voltage | 3 % |
relative control precision of the output voltage | |
● on slow fluctuation of input voltage | 0.1 % |
● on slow fluctuation of ohm loading | 0.1 % |
residual ripple | |
● maximum | 100 mV |
● typical | 30 mV |
voltage peak | |
● maximum | 100 mV |
● typical | 50 mV |
display version for normal operation | Green LED for output voltage OK |
behavior of the output voltage when switching on | No overshoot of Vout (soft start) |
response delay maximum | 0.5 s |
voltage increase time of the output voltage | |
● typical | 100 ms |
output current | |
● rated value | 6.3 A |
● rated range | 0 … 6.3 A; +55 … +70 °C: Derating 2%/K |
supplied active power typical | 31.5 W |
bridging of equipment | Yes |
number of parallel-switched equipment resources for increasing the power |
2 |
efficiency | |
efficiency in percent | 79.8 % |
power loss [W] | |
● at rated output voltage for rated value of the output current typical |
8 W |
● during no-load operation maximum | 0.3 W |
closed-loop control | |
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical |
0.2 % |
relative control precision of the output voltage at load step of resistive load 10/90/10 % typical |
7 % |
setting time | |
● load step 10 to 90% typical | 1 ms |
● load step 90 to 10% typical | 1 ms |
protection and monitoring | |
design of the overvoltage protection | Yes, according to EN 60950-1 |
property of the output short-circuit proof | Yes |
design of short-circuit protection | Constant current characteristic |
● typical | 8.2 A |
overcurrent overload capability | |
● when switching on | 150% Iout rated typ. 200 ms |
● in normal operation | overload capability 150% Iout rated typ. 200 ms |
enduring short circuit current RMS value | |
● maximum | 8.2 A |
measuring point for output current | Yes; 50 mV =^ 6.3 A |
safety | |
galvanic isolation between input and output | Yes |
galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 |
operating resource protection class | Class II (without protective conductor) |
protection class IP | IP20 |
EMC | |
standard | |
● for emitted interference | EN 55022 Class B |
● for mains harmonics limitation | not applicable |
● for interference immunity | EN 61000-6-2 |
standards, specifications, approvals | |
certificate of suitability | |
● CE marking | Yes |
● UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus- Recognized (UL 60950, CSA C22.2 No. 60950), File E151273 |
● CSA approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus- Recognized (UL 60950, CSA C22.2 No. 60950), File E151273 |
● EAC approval | Yes |
● NEC Class 2 | No |
● SEMI F47 | Yes |
type of certification | |
● CB-certificate | Yes |
MTBF at 40 °C | 2 654 280 h |
standards, specifications, approvals hazardous environments | |
certificate of suitability | |
● IECEx | No |
● ATEX | No |
● ULhazloc approval | No |
● cCSAus, Class 1, Division 2 | No |
● FM registration | No |
standards, specifications, approvals marine classification | |
shipbuilding approval | Yes |
Marine classification association | |
● American Bureau of Shipping Europe Ltd. (ABS) | Yes |
● French marine classification society (BV) | Yes |
● Det Norske Veritas (DNV) | Yes |
● Lloyds Register of Shipping (LRS) | Yes |
standards, specifications, approvals Environmental Product Declaration | |
Environmental Product Declaration | Yes |
global warming potential [CO2 eq] | |
● total | 222.9 kg |
● during manufacturing | 3.8 kg |
● during operation | 218.9 kg |
● after end of life | 0.14 kg |
ambient conditions | |
ambient temperature | |
● during operation | -25 … +70; with natural convection |
● during transport | -40 … +85 |
● during storage | -40 … +85 |
environmental category according to IEC 60721 | Climate class 3K3, 5 … 95% no condensation |
connection method | |
type of electrical connection | screw terminal |
● at input | L, N: 1 screw terminal each for 0.5 … 2.5 mm2 single-core/finely stranded |
● at output | +, -: 1 screw terminal each for 0.5 … 2.5 mm² |
● for auxiliary contacts | – |
mechanical data | |
width × height × depth of the enclosure | 54 × 90 × 53 mm |
installation width × mounting height | 54 mm × 130 mm |
required spacing | |
● top | 20 mm |
● bottom | 20 mm |
● left | 0 mm |
● right | 0 mm |
fastening method | Snaps onto DIN rail EN 60715 35×7.5/15, direct mounting in different mounting positions |
● DIN-rail mounting | Yes |
● S7 rail mounting | No |
● wall mounting | Yes |
housing can be lined up | Yes |
net weight | 0.2 kg |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)