Limit Switches OsiSense XC Standard – ZCKM – Schneider Limit Switches

$ 22.00$ 32.78

SKU: N/A

Specifications

Main information
Part Number ZCKM1C ZCKM1 ZCKM1H29C
Product Series Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Serial Number Standard type Standard type Standard type
product type Limit switch body Limit switch body Limit switch body
product short name BYZGR BYZGR BYZGR
ontology type Fixed Fixed Fixed
The scope of products XCKM XCKM XCKM
connected head ZCKD08 ZCKD08 ZCKD59
ZCKD219 ZCKD06 ZCKD10
ZCKD16 ZCKD219 ZCKD23
ZCKD15 ZCKD41 ZCKD17
ZCKD05 ZCKD02 ZCKD05
ZCKD06 ZCKD81 ZCKD029
ZCKD109 ZCKD05 ZCKD15
ZCKD17 ZCKD109 ZCKD08
ZCKD029 ZCKD16 ZCKD16
ZCKD21 ZCKD23 ZCKD219
ZCKD10 ZCKD91 ZCKD06
ZCKD02 ZCKD029 ZCKD41
ZCKD17 ZCKD02
ZCKD59 ZCKD21
ZCKD15 ZCKD239
ZCKD21 ZCKD91
ZCKD239 ZCKD109
ZCKD10 ZCKD81
body material Metal Metal Metal
cable entry hole 3 pg11 cable glands 3 pg11 cable glands 3-hole cable entry for M20 x 1.5 cable glands
number of poles 2 2 2
contact type 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
contact action Momentary Momentary Momentary
Step count 1 1 position 1 1 position 1 1 position
contact material Silver plated contacts Silver plated contacts Silver plated contacts
Additional information
local display None None None
Electrical connections Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm²
Force open Have Have Have
minimum braking speed 0.01 m/min 0.01 m/min 0.01 m/min
Rated operating current [Ie] 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A
Conventional enclosed heating current [Ithe] 10A 10A 10A
Rated insulation voltage [Ui] 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block
300 V conforming to CSA C22.2 No 14 for contact block 300 V conforming to CSA C22.2 No 14 for contact block 300 V conforming to CSA C22.2 No 14 for contact block
300 V conforming to UL 508 for contact block 300 V conforming to UL 508 for contact block 300 V conforming to UL 508 for contact block
Maximum resistance across terminals 0.25 mΩ conforming to IEC 60255-7 Safety Class 3 0.25 mΩ conforming to IEC 60255-7 Safety Class 3 0.25 mΩ conforming to IEC 60255-7 Safety Class 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60664 6 kV according to IEC 60664 6 kV according to IEC 60664
6 kV according to IEC 60947-1 6 kV according to IEC 60947-1 6 kV according to IEC 60947-1
Short circuit protection 10 A fuse fuse, type gG 10 A fuse fuse, type gG 10 A fuse fuse, type gG
Electrical life 5000000 cycles, DC-13 120 V, 7 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 5000000 cycles, DC-13 120 V, 7 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 5000000 cycles, DC-13 120 V, 7 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13
24 V, 13 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 13 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 24 V, 13 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C
5000000 cycles, DC-13 48 V, 9 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C 5000000 cycles, DC-13 48 V, 9 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C 5000000 cycles, DC-13 48 V, 9 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C
Width 64 mm 64 mm 64 mm
High 64 mm 64 mm 64 mm
Depth 30 mm 30 mm 30 mm
Product weight 0.21kg 0.21kg 0.21kg
ISO n°1 terminals (21-22)NC (21-22)NC (13-14)NO
(13-14)NO (13-14)NO (21-22)NC
Environment
IP rating IP66 IP66 IP66
IK level IK05 IK05 IK05
Ambient temperature -25…70 °C for standard environment -25…70 °C for standard environment -25…70 °C for standard environment
Storage environment temperature -40…70°C -40…70°C -40…70°C
Environmental features Standard environment Standard environment Standard environment
Packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 8.1 cm 3.200 cm 8.1 cm
Package 1 Width 3.2cm 6.500 cm 3.2cm
Package 1 Length 6.4cm 9.700 cm 6.4cm
Package 1 Weight 218.58g 234.000g 219.0g
Unit Type of Package 2 P06 S01 S02
Number of Units in Package 2 1024 20 60
Package 2 Height 75.0cm 15.000 cm 15.0cm
Package 2 Width 60.0cm 15.000 cm 29.9 cm
Package 2 Length 80.0cm 40.000 cm 39.8 cm
Package 2 Weight 243.842 kg 4.879 kg 13.51kg
Unit Type of Package 3 CAR P06 P06
Number of Units in Package 3 16 640 960
Package 3 Height 15.0cm 77.000 cm 75.0cm
Package 3 Width 15.0cm 80.000 cm 60.0cm
Package 3 Length 20.0cm 60.000 cm 80.0cm
Package 3 Weight 3.654 kg 164.180kg 226.161 kg
Contract warranty
Warranty 18 months 18 months 18 months
Weight N/A
Dimensions N/A
Model

ZCKM1, ZCKM1C, ZCKM1H29C